• 제목/요약/키워드: Performance Diagnostic Program

검색결과 61건 처리시간 0.027초

뇌 관류 SPECT 스캐너의 정도관리-균일도에 따른 팬텀 영상 평가 (Phantom Image Evaluations Depending on the Quality Control-Uniformity of Brain Perfusion SPECT Scanner)

  • 김정수;양현진;김준;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.29-36
    • /
    • 2023
  • To have highly reliable diagnostic performance of it, this study comparatively analyzed spatial resolution of SPECT images and interrelationship depending on the changes of system uniformity of ga㎜a camera through phantom analysis. This study chose 6 kinds of results from quality control (uniformity) of triple head SPECT scanner operated in an university hospital in Seoul for six months. Then, study measured spatial resolutions (FWHM) of the images restructured by injecting radiopharmaceuticals to Jaszczak phantom, and doing SPECT scanning under the same conditions as clinical ones using the analytical program (image J). Quality controls performed by the experimental institution showed that differential uniformity of UFOV ranged from 2.76% to 7.61% (4.46±2.07), and integral uniformity of UFOV ranged from 1.98% to 5.42% (3.01±1.43). Meanwhile, Quantitative analysis evaluations of phantom images depending on the changes of uniformity of SPECT scanner detector showed that as the uniformity values of UFOV and CFOV decreased, FWHM values of phantom images decreased from 8.5 ㎜ to 5.8 ㎜. That is, it was quantitatively identified that the higher uniformity of detector is, the better spatial resolution of images gets (P<0.05). It is very important to perform continuous and consistent quality control of the nuclear medicinal system, and users should be clearly conscious of it.

산란계의 전염성 기관지염을 예측하기 위한 인공신경망 모형의 개발 (Development an Artificial Neural Network to Predict Infectious Bronchitis Virus Infection in Laying Hen Flocks)

  • 박선일;권혁무
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.105-110
    • /
    • 2006
  • 2003년 5월부터 2005년 11월까지 산란계의 전염성기관지염(IB) 예찰 프로그램에 등록한 농장에 대한 역학조사에서 얻은 자료에 근거하여 IB 감염을 확인할 수 있는 모형을 구축하기 위하여 16개의 입력 뉴런, 3 개의 은닉 뉴런, 1개의 출력 뉴런으로 구성된 3층 인공신경망 모형을 개발하였다. 총 86개의 계군 중 77개는 훈련자료에 할당하고 나머지 9개는 검정자료로 무작위로 할당하여 back-propagation algorithm으로 신경망 훈련을 수행하였다. 입력 뉴런은 산란계군의 특성, 사양관리, 계군의 크기 등 16개의 역학조사 항목을 사용하였으며 출력 뉴런은 IB 감염의 유무로 투입하였다. 훈련된 신경망을 검정자료에 적용하여 민감도와 특이도를 산출하였으며 진단의 정확도는 receiver operating characteristic (ROC) 곡선을 사용하여 곡선 밑의 면적(AUC)을 계산하여 평가하였다. 입력 뉴런의 특성과 훈련모수를 변경하면서 다양한 신경망을 구성하였으며 최적의 신경망으로 확인된 IBV_D1 신경망의 경우 훈련자료에 대하여 77건 중 73건을 올바르게 판단하여 94.8%의 정확도를 보였다. 민감도와 특이도는 각각 95.5% (42/44, 95% CI, 84.5-99.4)와 93.9% (31/33, 95% CI, 79.8-99.3)로 나타났다. 훈련된 신경망을 검정자료에 적용하여 ROC 곡선을 작성한 결과 AUC는 전체의 94.8% (SE=0.086, 95% CI 0.592-0.961)를 차지하는 우수한 모형으로 나타났다. ROC 곡선에서 기준을 0.7149 이상으로 판단할 때 진단의 정확도가 88.9%로 가장 높았으며 100%의 민감도를 달성하였다. 이러한 민감도와 특이도에서 44%의 IB 유병률을 가정할 때 IBV_D1 모형은 80%의 양성예측도와 100%의 음성예측도를 보였다. 이러한 소견에 근거할 때 본 연구에서 구축한 신경망 모형은 산란계군에서 IB의 존재를 확인하기 위한 목적에 성공적으로 응용될 수 있을 것으로 판단되었다.

해녀 우울장애 환자의 임상적 특징 (Clinical Characteristics of Haenyeo with Depressive Disorders)

  • 박준혁;전병선;이창인;김문두;정지운;정영은
    • 생물정신의학
    • /
    • 제23권2호
    • /
    • pp.63-68
    • /
    • 2016
  • Objectives Haenyeo are Korean professional women breath-hold divers in Jeju island. The aim of this study was to investigate the clinical characteristics of depressed Haenyeo group, compared to non-Haenyeo depressed group. Methods This study included 75 Haenyeo and 340 non-Haenyeo with depressive disorders recruited from the Dementia Early Detection Program in Jeju island. Structural diagnostic interviews were performed using the Korean version of Mini International Neuropsychiatric Interview. All patients completed the questionnaires, including the Subjective Memory Complaints Questionnaire (SMCQ), the Patient Health Questionnaire-15 (PHQ-15), and the Blessed dementia scale. Depression was evaluated by the Korean version of short form the Geriatric Depression Scale (K-SGDS) and cognition was assessed by the Korean version of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) assessment packet. Results Although the mean scores of the K-SGDS were similar between Haenyeo and non-Haenyeo depressed groups, the Haenyeo group showed a higher mean score on the PSQ-15 (p < 0.001, ANCOVA adjusting for age, the K-SGDS and education). The Haenyeo group showed poorer performance on the Korean Version of Frontal Assessment Batter (p < 0.001), the Mini-Mental State Examination in the Korean version of the CERAD Assessment Packet (p < 0.018), the word fluency test (p < 0.001), and the word list memory test (p = 0.012) in ANCOVA adjusting for age and education. The mean SMCQ score was higher in the Haenyeo depressed group than in the non-Haenyeo depressed group. Conclusions The Haenyeo depressed group shows cognitive dysfunction, especially frontal lobe dysfunction, compared to the non-Haenyeo depressed group, indicating the Haenyeo depressed group may have more severe frontolimbic dysfunction due to chronic exposure to hypoxia. The Haenyeo depressed group suffers more somatic symptoms than the non-Haenyeo depressed group.

의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발 (Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator)

  • 곽동훈;이상헌;이승호
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.495-498
    • /
    • 2018
  • 본 논문에서는 의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP)의 시스템을 제안한다. 제안하는 시스템은 Ion-Chamber를 이용한 면적선량 측정기술을 기반으로 진단용 X-선 장치에 의해 발생된 피폭선량을 명확히 측정할 수 있다. 면적선량계의 하드웨어부는 공기 중에서 X-선에 의해 전리되는 전하의 양을 측정한다. 미소 전류를 통한 누적선량 측정을 위한 고속 처리 알고리즘부는 입력 손실 없이 낮은 구현비용(전력)으로 X-선에 의해 전리되는 전하의 양을 측정한다. X-선 발생장치의 동작에 동기화된 유무선 송수신 프로토콜부는 통신 속도를 향상시킨다. 연동 및 에이징을 위한 PC 기반 제어 프로그램부는 실시간으로 발생된 X-선량을 측정하여 PC용 GUI를 통해 측정 그래프 및 수치 모니터링이 가능하도록 한다. 제안된 시스템의 성능을 공인시험기관에서 평가한 결과, 각각의 에너지 대역(30, 60, 100, 150kV)에서 면적선량계에 측정되는 값이 선형적으로 증가됨을 확인할 수가 있었다. 또한 4등분한 지점에서 측정기의 지시치에 대한 표준편차가 ${\pm}1.25%$를 나타내어서 면적선량계가 위치에 관계없이 균일한 측정값을 나타냄을 확인하였다. 한편, ${\pm}4.2%$의 불확도가 측정되어서 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과 (The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom)

  • 김연민;심재구;김상현
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.221-225
    • /
    • 2017
  • 초음파영상 진단장치의 성능을 평가할 때, 초음파장비에서 제공하는 음속변화 파라메타를 변화시킴에 따른 공간분해능의 변화를 알아보고자 하였다. 익산 소재 A기관에서 사용중인 초음파 진단장치에서 3.0 ~ 5.0 MHz 볼록형 탐촉자를 이용하여 초음파팬텀영상를 얻었다. N-365 다목적 초음파팬텀으로 종거리 측정정확도, 종 횡 해상도를 측정하였다. 같은 방법으로 초음파장치의 음속을1580 m/sec부터 1400 m/sec 까지 6단계로 변화시켜 측정 값의 차이가 있는지 image J 프로그램을 이용하여 반치폭을 측정하였다. 측정 결과, 횡측해상도는 속도변화에 따라 1.91 mm ~ 5.3 mm까지 측정되었으며, 음속 1420 m/sec 일 때 반치폭 1.91 mm로 가장 작게 측정되었다. 종측해상도는 1.03 mm ~ 1.14 mm까지 측정되었으며, 음속 1400 m/sec 일 때 반치폭 1.03 mm 로 가장 작게 측정되었다. 초음파장치의 음속이 느려질수록 종측정 길이가 짧아지는 상관관계를 보였다.

Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구 (Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm)

  • ;김태형;천송이;한용희;최기승;이광식;전재량;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권2호
    • /
    • pp.131-141
    • /
    • 2008
  • 목적: 물체 내부의 온도를 비침습적으로 측정할 수 있는 양성자 공명 주파수 이동에 의한 MR 온도영상의 재구성에 center array-sequencing 위상펼침(PU) 기법을 적용시켜 그 성능 및 유용성을 평가하고자 하였다. 대상 및 방법: MR 온도 영상에 앞서 잡음 수준이 다른 타원형 팬텀들을 컴퓨터 모의 실험으로 제작하고 제안된 PU방 법을 적용시켜 잡음에 대한 성능을 평가하였다. MR 실험은 PU 실험과 이를 이용한 온도분포영상획득 실험으로 구분하여 수행되었다. 1.5T MR 영상장치에서 무릎코일과 $T2^*$ 경사자장에코 펄스열을 이용하여 MR 영상을 얻었다. 물통, 오렌지, 아가젤 등의 팬텀을 실험 대상으로 하였고 자체 제작된 온수펌프 장치로 팬텀의 온도를 조절하였다. T 형 열전쌍 온도측정장치로 팬텀 온도를 측정하고 MR 온도영상 결과와 비교하였다. 획득된 MR영상의 위상분포는 제안된 PU방법으로 위상을 편 후 온도분포 영상을 재구성하였다. 가열 전 후의 온도변화와 MR 영상의 위상변화 관계를 이용하여 아가젤 팬텀 내의 MR온도분포 영상을 구하였다. 결과: 제안된 center array-sequencing PU 알고리즘을 이용하여 여러 팬텀에 대한 MR 위상영상의 접힘 현상을 기존 방법보다 간편하고 빠르게 제거할 수 있었고 이를 이용하여 MR 온도영상을 획득할 수 있었다. 결론: 본 연구는 제안된 center array-sequencing 위상펼침 방법이 잡음에 강하고 처리 속도가 빠를 뿐만 아니라 양성자 공명 주파수 이동의 성질을 이용한 MR 온도 영상 획득에 성공적으로 적용될 수 있음을 보였다.

  • PDF

두경부 위치에 따른 측두하악장애환자의 하악 torque 회전운동 분석 (Effects of Head Posture on the Rotational Torque Movement of Mandible in Patients with Temporomandibular Disorders)

  • 박혜숙;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제25권2호
    • /
    • pp.173-189
    • /
    • 2000
  • The purpose of this study was to evaluate the effect of specific head positions on the mandibular rotational torque movements in maximum mouth opening, protrusion and lateral excursion. Thirty dental students without any sign or symptom of temporomandibular disorders(TMDs) were included as a control group and 90 patients with TMDs were selected and examined by routine diagnostic procedure for TMDs including radiographs and were classified into 3 subgroups : disc displacement with reduction, disc displacement without reduction, and degenerative joint disease. Mandibular rotational torque movements were observed in four head postures: upright head posture(NHP), upward head posture(UHP), downward head posture(DHP), and forward head posture(FHP). For UHP, the head was inclined 30 degrees upward: for DHP, the head was inclined 30 degrees downward: for FHP, the head was positioned 4cm forward. These positions were adjusted with the use of cervical range-of-motion instrumentation(CROM, Performance Attainment Inc., St. Paul, U.S.A.). Mandibular rotational torque movements were monitored with the Rotate program of BioPAK system (Bioresearch Inc., WI, U.S.A.). The rotational torque movements in frontal and horizontal plane during mandibular border movement were recorded with two parameters: frontal rotational torque angle and horizontal rotational torque angle. The data obtained was analyzed by the SAS/Stat program. The obtained results were as follows : 1. The control group showed significantly larger mandibular rotational angles in UHP than those in DHP and FHP during maximum mouth opening in both frontal and horizontal planes. Disc displacement with reduction group showed significantly larger mandibular rotational angles in DHP and FHP than those in NHP during lateral excursion to the affected and non-affected sides in both frontal and horizontal planes(p<0.05). 2. Disc displacement without reduction group showed significantly larger mandibular rotational angles in FHP than those in any other head postures during maximum mouth opening as well as lateral excursion to the affected and non-affected sides in both frontal and horizontal planes. Degenerative joint disease group showed significantly larger mandibular rotational angles in FHP than those in any other head postures during maximum mouth opening, protrusion and lateral excursion in both frontal and horizontal planes(p<0.05). 3. In NHP, mandibular rotational angle of the control group was significantly larger than that of any other patient subgroups. Mandibular rotational angle of disc displacement with reduction group was significantly larger than that of disc displacement without reduction group during maximum mouth opening in the frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of disc displacement with reduction group or degenerative joint disease group during maximum mouth opening in the horizontal plane(p<0.05). 4. In NHP, mandibular rotational angles of disc displacement without reduction group were significantly larger than those of the control group or disc displacement with reduction group during lateral excursion to the affected side in both frontal and horizontal planes. Mandibular rotational angle of disc displacement without reduction group was significantly smaller than that of the control group during lateral excursion to the non-affected side in frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of disc displacement with reduction group during lateral excursion to the non-affected side in the horizontal plane(p<0.05). 5. In NHP, mandibular rotational angle of the control group was significantly smaller than that of disc displacement with reduction group or disc displacement without reduction group during protrusion in the frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of the disc displacement with reduction group or degenerative joint disease group during protrusion in the horizontal plane. Mandibular rotational angle of the control group was significantly smaller than that of disc displacement without reduction group or degenerative joint disease group during protrusion in the horizontal plane(p<0.05). 6. In NHP, disc displacement without reduction group and degenerative joint disease group showed significantly larger mandibular rotational angles during lateral excursion to the affected side than during lateral excursion to the non-affected side in both frontal and horizontal planes(p<0.05). The findings indicate that changes in head posture can influence mandibular rotational torque movements. The more advanced state is a progressive stage of TMDs, the more influenced by FHP are mandibular rotational torque movements of the patients with TMDs.

  • PDF

Insulin 측정용 방사면역측정법 시약의 평가 (The Evaluation of Radioimmunoassay kits for Insulin)

  • 신용환;김윤현;이일규;김지영;석재동;신숙희
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2012
  • 혈중 Insulin 농도는 췌장 ${\beta}$세포의 인슐린 분비기능을 반영하고 당뇨병의 진단, 병태 파악, 내당능 이상의 원인감별에 유용한 지표이다. 핵의학검사실에서 사용하고 있는 혈중 Insulin 측정용 시약들은 제조회사마다 검사방법 뿐만 아니라 비용효과 측면, 정밀도 등 정도관리 측면에서도 다소 차이를 보이고 있다. 따라서 Insulin 측정용 방사면역측정법 시약들의 제조 회사별 비교를 통해 진단적 성능을 평가하고자 본 연구를 시행하였다. 2009년 8월 59명의 환자 검체를 대상으로 시행된 3개 제조회사(Biosource, Siemens, TFB)의 혈중 Insulin측정치와 2011년 12월 68명의 환자 검체를 대상으로 시행된 4개 제조회사(Immunotech, Izotope, BNIBT, Cisbio)의 혈중 Insulin측정치를 비교 평가하였다. 이들 7개 제조회사별 Insulin측정치에 대하여 정밀도, 회수율, 상관관계를 살펴보았으며 일부 인슐린 고농도 특이검체를 가지고 희석시험을 통해 혈중 Insulin측정치를 상호 비교 평가하였다. 혈중 Insulin 측정은 시약 내 설명서의 권고사항을 준수하여 실시하였으며 결과 검증을 위한 통계 프로그램은 SPSS 12.0을 이용하였다. 측정 내 정밀도는 Biosource, Siemens, TFB, Immunotech, Izotope, BNIBT, Cisbio 7개 제조회사 모두 5.0% 이하의 변이계수를 보였다. 회수율은 저, 중, 고 세가지 농도의 혈청에서 Biosource, Siemens, TFB시약이 각각 94.2~103.7%, 99.0~104.6%, 99.7~107.6% 구간을 보였고 Immunotech, Izotope, BNIBT, Cisbio 시약에서 각각 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% 구간의 회수율을 보였다. Biosource 시약을 기준으로 비교한 상관관계에서 Siemens 시약이 R2=0.96(P<0.01), TFB시약이 R2=0.99(P<0.01)를 보였으며 TFB 시약을 기준으로 비교한 상관관계에서는 BNIBT시약(R2=0.80, P<0.01)을 제외한 대부분의 시약에서 강한 상관관계(R2=0.96 이상, p<0.01)를 보였다. 200 ${\mu}IU/ml$ 이상 고농도 희석시험에서는 당뇨병환자 검체를 대상으로 했을 때 7개 제조회사 시약 모두 고농도값을 정상적으로 측정하였다. 하지만, 인슐린 종양 검체를 대상으로 측정한 검사에서는 TFB, Siemens, Izotope, Cisbio시약들은 고농도값을 정상적으로 측정하였지만 Biosource와 Immunotech 시약에서 각각 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$의 측정치를 보였다. 혈중 Insulin 측정용 방사면역측정법 시약들은 전반적으로 성능이 임상 적용 가능한 범위의 측정 정밀도를 보이면서, 우수한 회수율과 양호한 상관관계를 보였지만 일부 시약에서 고농도 특이검체를 대상으로 Insulin을 측정한 검사에서 고농도값을 제대로 측정하지 못했다. 따라서 여러가지 요인을 놓고 볼 때 비용 효과측면과 자동화 장비에 대한 호환성, 검사 반응시간등 각 검사실 환경에 맞는 시약과 진단적 성능이 보다 우수한 시약을 선정하여 사용한다면 정확하고 신속한 결과보고에 있어서 많은 도움이 된다고 사료된다.

  • PDF

DTPA-bis(4-carboxycyclohexyl)amide 상자성 복합체의 자기이완특성에 관한 연구 (The Magnetic Relaxation Properties of DTPA-bis(4-carboxycyclohexyl) amide Paramagnetic Gd-chelates)

  • 김인성;이영주;이재준;김주현;김유경;;김숙경;김태정;강덕식;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권1호
    • /
    • pp.20-25
    • /
    • 2006
  • 목적 : 새로 개발한 상자성 복합체의 자기이완 특성을 조사해 보고자 하였다. 대상 및 방법 : DMF(15 mL)와 DTPA-bis-anhydride(0.71g, 2 mmol)의 서스펜션 용액에 4-aminomethylcyclohexane carboxylic acid(0.63g, 4 mmol)를 넣어 리간드를 합성한 후 Gd2O3(0.18g, 0.5 mmol)을 넣어 최종적인 Gd 착화물을 합성하였다. 상자성 복합체의 자기이완율을 측정하기 위해 상자성 복합체를 3차 증류수를 사용하여 1 mM로 희석시켰으며 1.5T(64 MHz)에서 자기이완 시간을 측정하였다. T1 자기이완시간을 측정하기 위하여 반전 회복(inversion-recovery) 펄스열을 사용하였으며 T2 자기이완시간은 CPMG(Carr-Purcell-Meiboon-Gill) 펄스열을 사용하였다. 자기이완 시간 및 자기이완율을 영상으로 표현한 T1 자기이완 지도, R1 지도, T2 자기이완 지도 및 R2 지도를 구현 하였다. 결과 : 현재 시판중인 상자성 조영제인 Omniscan(Gadodiamide)의 $R1=4.9mM^{-1}sec^{-1},\;R2=4.8mM^{-1}sec^{-1}$에 비해 R1의 경우 SUK090(Gd-C32H74N5O24)는 $12.46mM^{-1}sec^{-1}$, SUK091(Gd-C34H78N5O24)는 $12.77mM^{-1}sec^{-1}$의 값을 나타낸 반면 SUK092(Gd-C30H56N5O17)는 $2.09mM^{-1}sec^{-1}$로 자기이완율이 감소하였다. R2의 경우 SUK090(Gd-C32H74N5O24)는 $8.76mM^{-1}sec^{-1}$, SUK091(Gd-C34H78N5O24)는 $7.60mM^{-1}sec^{-1}$의 값을 나타낸 반면 SUK092(Gd-C30H56N5O17)는 $1.82mM^{-1}sec^{-1}$로 감소 하였다. 결론 : 본 연구에서 합성한 상자성 복합체중 SUK090(Gd-C32H74N5O24)와 SUK091(Gd-C34H78N5O24)는 기존의 상자성 조영제에 비해 T1, T2 자기이완율이 크고 결과적으로 T1/T2 조영증강 효과가 클 것으로 예상된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF