• 제목/요약/키워드: Performance Control

Search Result 25,332, Processing Time 0.18 seconds

A Study on the Improvement of Control System Performance of Drum Boiler (드럼보일러의 제어성 개선에 관한 연구)

  • Seon, Yang-Rae;Bang, Si-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.2
    • /
    • pp.43-55
    • /
    • 1988
  • The control system of a drum boiler is very complex since the evaporization process in the boiler is a multivariable system which is affected one another. This study is concerned with the dynamic characteristics of the boiler process and improving methods of performance of a drum boiler control system. The PID control with feedforward of disturbances and the optimal regulator are compared, and the effects of control parameters on the performance of a boiler control system are investigated. From simulation, it is found that profer adjustment of control parameters significant improvement of response and that performance of a optimal regulated control system is better than that of a conventional PID control system.

  • PDF

Robust Trajectory Tracking Control of Mecanum Wheeled AGV Using State Space Disturbance Observer Based Impedance Control and ISMC (상태 공간 외란관측기 기반의 임피던스 제어와 ISMC를 이용한 메카넘 휠 AGV의 강인 궤도 추적 제어)

  • Hyoseok Cheon;Seungkyu Park
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • Auto Guided Vehicle (AGV) equipped with mecanum wheels can move in all directions, unlike ordinary wheeled AGVs. In this paper, we propose a robust trejectory tracking control method for the mecanum wheeled AGVs in the presence of disturbances. It is constructed by combining impedance control with Integral Sliding Mode Control (ISMC), which shows robust performance against disturbances, and adding a disturbance observer (DOB) that estimates and removes disturbances. Simulation result using MATLAB/SIMULINK shows that the proposed control method has robust performance in tracking the reference trajectory under the circumstance with disturbance. The control performance is further improved when the disturbance observer is additionally used. In addition, the performance of the proposed control method was verified through experiment. It shows the result of tracking the set trajectory well.

Incorporating Performance Degradation in Fault Tolerant Control System Design with Multiple Actuator Failures

  • Zhang, Youmin;Jiang, Jin;Theilliol, Didier
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.3
    • /
    • pp.327-338
    • /
    • 2008
  • A fault tolerant control system design technique has been proposed and analyzed for managing performance degradation in the presence of multiple faults in actuators. The method is based on a control structure with a model reference reconfigurable control design in an inner loop and command input adjustment in an outer loop. The reduced dynamic performance requirements in the presence of different actuator faults are accounted for through different performance reduced (degraded) reference models. The degraded steady-state performances are governed by the reduced levels of command input. The reconfigurable controller is designed on-line automatically in an explicit model reference control framework so that the dynamics of the closed-loop system follow that of the performance reduced reference model under each fault condition. The reduced command input level is determined to prevent potential actuator saturation. The proposed method has been evaluated and analyzed using an aircraft example against actuator faults subject to constraints on the magnitude and slew-rate of actuators.

Awareness and Performance of Healthcare-Associated Infections Control and Psycological Empowerment of Intensive Care Unit Nurses (중환자실 간호사의 심리적 임파워먼트와 의료관련감염 관리의 인지도 및 수행도)

  • Lee, Seon Ju;Yang, Nam Young
    • Journal of Home Health Care Nursing
    • /
    • v.24 no.3
    • /
    • pp.306-315
    • /
    • 2017
  • Purpose: This study was conducted to examine psychological empowerment and awareness and performance of Healthcare-Associated Infections(HAIs) control among Intensive Care Unit (ICU) nurses. Method: The data for this study were collected using structured questionnaires from 178 nurses working in the ICUs of four hospitals with more than 500 beds. Results: The subjects'psychological empowerment, awareness and performance of HAIs control were mean over. The subjects'psychological empowerment showed statistically significant differences depending on age, marital status, academic background, clinical career, ICU career, and position and experience in infection control among their general characteristics. Awareness of HAIs control showed statistically significant differences depending on age, gender, marital status, clinical career, and ICU career. Performance showed statistically significant differences depending on age, gender, marital status, and, ICU career. Regarding the subjects' performance of HAIs control, there was a statistically significant positive correlation between psychological empowerment and awareness. Conclusion: It was found that it is necessary to strengthen differential customized training according to the subjects'characteristics for effective HAIs control, and to strengthen the nurses'awareness of HAIs control through systematic evaluation, monitoring, and feedback, as well as continuous education and training.

The Effects of Simulation-based Infection Control Training on the Intensive Care Unit Nurses' Perception, Clinical Performance, and Self-Efficacy of Infection Control (시뮬레이션기반 감염관리교육이 중환자실 간호사의 감염 관리에 대한 인식도, 임상 수행도, 자기효능감에 미치는 영향)

  • Cho, Sung Sook;Kim, Kyung Mi;Lee, Beoung Yeo;Park, Sun A
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.3
    • /
    • pp.381-390
    • /
    • 2012
  • Purpose: This study was conducted to examine the effects of simulation-based infection control training on the ICU nurses' perception, clinical performance, and self-efficacy of infection control. Methods: Thirty-eight nurses were assigned into two groups using a career stratified randomization. In the experimental group, the subjects received a simulation-based infection control training, whereas the control group participated in a conventional lecture-based training. Two weeks after the completion of the training sessions, the participants were evaluated for perception, clinical performance, and self-efficacy regarding the infection control. Results: The experimental group that received simulation-based infection control training showed an improvement in perceiving the infection control compared to that of the control group, but the difference was not statistically significant. In terms of the clinical performance, the experimental group and the control group scored $26.05{\pm}3.22$ and $18.53{\pm}3.37$ points respectively, demonstrating a statistical significance (p<.001). There was no significant difference between the two groups in regards to the self-efficacy. Conclusion: The developed simulation-based infection control training showed positive effects in improving clinical performance of infection control over conventional lecture-based training, confirming that a simulation-based training is an effective method in advancing the practical performance of ICU nurses.

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

A Time series Analysis on the Performance Items of the "Housing Performance Grading Indication System" (주택성능등급표시제도 성능항목의 특성 및 시계열분석( I ))

  • Lee, Sung-Ok;Kim, Soo-Am;Shin, Sung-Eun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.213-216
    • /
    • 2009
  • The purpose of this study is analyzing temporal flow about 20 detailed performance items in the "Housing Performance Grading Indication System". This study try to figure out situations according grade in detailed performance item and to analyze change item about 112 cases(2 cases in 2006, 15 cases in 2007, 46 cases in 2008, 49 cases in 2009), from January 9, 2006 which system is undertaken, to October, 2009. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control & ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). Total efficiency about housing can understand systematically of 20 perfomance items though this research.

  • PDF

A Study on Improvement of Flexibility for the Activation of the "Housing Performance Grading Indication System" (주택성능등급표시제도의 활성화를 위한 가변성 성능범주의 현황 및 개선방안연구)

  • Lee, Sung-Ok;Kim, Soo-Am
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.479-482
    • /
    • 2008
  • The purpose of this study is a proposal about the flexibility of the performance category to revitalize the "Housing Performance Grading Indication System". This system consists of 5 main performance parts, 14 performance categories and 20 detailed performance lists. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control& ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). The flexibility of the performance category is conformed to Long-life housing related grading and can realize the Long-life housing in response to resident needs about the space rearrangement. Now, The flexibility of the performance category is limited to the evaluation of the private space, that is, the Skeleton evaluation. This study would suggest alternatives to improve uppermost limits through analyzing 60 examples from January 9th 2009 to October 30th 2008. The flexibility of the performance category is possible to estimate not only the Skeleton evaluation but also the Infill evaluation in response to social changes.

  • PDF

Electronic-hydraulic Hitch Control System for Agricultural Tractor -Draft Control- (트랙터의 전자유압식(電子油壓式) 히치 제어(制御) 시스템에 관한 연구(硏究)(II) -견인력제어(牽引力制御)-)

  • Yoo, S.N.;Ryu, K.H.;Yun, Y.D.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.229-241
    • /
    • 1989
  • The purposes of this study were to develop an electronic-hydraulic draft control system for tractor implements, to investigate the control performance of the system and the possibility of adaptation to the conventional tractor. Experiments were carried out to investigate the responses of the system to the step and sinusoidal inputs in draft control. The effects of control mode, hydraulic flow rate, reference deadband, and proportional constant on control performance of the system were investigated. Moreover, the effects of filtering signals from draft sensor were also investigated. The following conclusions were derived from the study; 1. In draft control, there were hunting problems in controlling the implement without filtering the draft signals. Filtering was performed by a control program of electronic controller and the control performance and stability of the system were improved significantly. 2. For the draft control system operated on on-off control mode, draft was controlled within ${\pm}27-{\pm}55kg_f$ to the reference draft when the hydraulic flow rates were 5-15 l/min. For the draft control system operated on PWM control, draft was controlled within ${\pm}27kg_f$ to the reference draft regardless of hydraulic flow rates. 3. In the frequency responses of the draft control system, control performance on PWM control mode was not better than on on-off control mode because of characteristics of hydraulic valve and drafe sensor. As the hydraulic flow rates increased for the system operated on on-off control mode, the corner frequency of amplitude attenuation increased, but the corner frequency of phase-angle change remained nearly the same. But, the system was unstable beyond the frequency of 3.1 rad/s. 4. The electronic-hydraulic hitch control system developed in this study showed superior control performance, stability and convenience compared to conventional mechanical-hydraulic hitch control system. It is considered to be a superior replacement for the conventional mechanical-hydraulic hitch control system.

  • PDF

The Performance Evaluation of NSSS Control Systems for UCN 4

  • Sohn, Suk-Whun;Song, In-Ho;Sohn, Jong-Joo;Park, Jong-Ho;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.339-348
    • /
    • 2001
  • NSSS Control Systems automatically mitigate transient conditions and leads to a stable plant condition without operator actions when a transient occurs during normal power operation. In this paper, the function and performance of NSSS control systems were examined and evaluated by comparing the predicted results with the measured data for the selected events. Loss of a Main Feedwater Pump and Load Rejection to House Load Operation events were selected for the evaluation among the transient tests peformed during the Power Ascension Test (PAT) of UCN unit 4. The overall schematic control actions of NSSS control systems can be evaluated easily through the observation of these two typical events. The selected events were analyzed by the KISPAC computer code[l] which had been used in developing the control logic and determining the control setpoints during the plant design. Additionally, the performance of FWCS during low power operation was evaluated. The result of evaluation showed that the NSSS control systems were designed properly and the performance of the NSSS control systems was excellent and also the computer code had a good prediction capability.

  • PDF