• Title/Summary/Keyword: Performance Control

Search Result 25,332, Processing Time 0.049 seconds

Performance Evaluation of Tuned Liquid Mass Damper for Reducing Bi-directional Responses of a Building Structure (건축구조물의 2방향 진동제어를 위한 TLMD 제어성능평가)

  • Heo, Jae-Sung;Lee, Sung-Kyung;Park, Eun-Churn;Lee, Sang-Hyun;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.432-441
    • /
    • 2008
  • In this study, the control performance of a Tuned Liquid Mass Damper(TLMD) manufactured to reduce the orthogonal bi-directional responses of building structures was experimentally evaluated. the TLMD using only one control device reduce bi-directional responses of building structures by making the TLMD behave as TMD and TLCD to the strong and weak axial direction of building structures. first, the control performance was evaluated by forcing sinusoidal waves to a test model that the TLMD is installed on the scale-downed building structure. Second, the real-time hybrid shaking table test was performed to evaluate the performance of the vibration control system made up of numerical part as a scale-downed building structural model and a physical experimental part as a TLMD. the superiority of bi-directional vibration control performance of the manufactured TLMD was verified by comparing the uncontrolled and controlled results of these tests.

  • PDF

Standardization of the Performance Test Procedure for Smoke Control System (제연설비 성능시험방법의 표준화)

  • Kwark, Ji-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.21-28
    • /
    • 2006
  • Since hot toxic gas included in the fire is the most principal reason of the death and has the fluid mechanical characteristics unlike air, smoke control method appropriate for the figure and structure of a fire room is needed and each unit of the smoke control system requests high performance according to this characteristics, for which performance test procedures and evaluation criteria must be established. Domestic criteria involved with the smoke control consist of the pre-investigation by documents and the part inspection, which has lots of problems because they are far from the performance based evaluation method compared with the references of developed countries. Consequently, domestic and international references were compared and analyzed, problems being emerged and standardization scheme of the test procedure was presented.

The Effect of Upper Extremity Training with a Focus on Functional Reaching, on Trunk Control and ADL Performance in Post-Stroke Hemiplegic Patients

  • Song, Bo-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.71-77
    • /
    • 2011
  • Purpose: In this study, we tried to determine the effect of upper extremity training such as functional reaching on improved trunk control and ADL performance in post-stroke hemiplegic patients. Methods: We randomly selected 11 stroke patients in the hospital, who had a problem with the upper extremity, trunk and ADL performance. The patients were divided into the conservative training group and the functional reaching training group. We applied general occupational therapy only in the conservative training group whereas we applied upper extremity training with a focus on functional reaching in the functional reaching training group. To compare the two groups we used several assessment tools such as Modified Barthel Index (MBI), total Trunk Impairment Scale (TIS), static TIS, dynamic TIS and coordinative TIS. Results: The results obtained were as follows: (1) In the functional reaching training group, there was a statistically significant difference in the total TIS score, dynamic TIS score, and MBI. (2) We compared the results obtained before training with the changes in the results obtained after training and found that there was a relation between the assessment outcomes. Especially, static TIS score showed a relation in both groups. Conclusion: Functional reaching training influenced both the trunk control and ADL performance. Especially, the functional reaching training group demonstrated better static trunk control ability than the conservative treatment group.

A Study on the Optimal Performance Control of Heat Pump System for Heating Mode Operation (열펌프 시스템의 난방 운전 시 최적 성능 제어에 관한 연구)

  • Yoo, Keun-Joong;Lee, Il-Hwan;Lee, Gil-Bong;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.669-674
    • /
    • 2006
  • The optimal control of heat pump performance for heating mode operation was investigated. Fuzzy logic was applied to control the heating performance of heat pump system and superheat at compressor discharge was taken as a control variable. Regression model was adapted to determine the optimal points where COP is maximized. Optimization of fuzzy rule table was investigated to improve operation performance of heat pump system. Experiments were carried out using original fuzzy table and the modified fuzzy rule table for heating mode operation of heat pump system. The results show that control performance of heat pump system with the modified fuzzy rule table was better than that with the original rule table.

  • PDF

Comparison of Effectiveness for Performance Tuning of Liquid Rocket Engine

  • Cho, Won Kook;Kim, Chun Il
    • International Journal of Aerospace System Engineering
    • /
    • v.5 no.2
    • /
    • pp.16-22
    • /
    • 2018
  • An analysis has been made on the performance variation due to pressure drop change at propellant supply pipes of liquid rocket engine. The objective is to compare the effectiveness of control variables to tune the liquid rocket engine performance. The mode analysis program has been used to estimate the engine performance for different modes which is realized by controlling the flow rate of propellant. The oxidizer of combustion chamber, the fuel of combustion chamber, the oxidizer of gas generator and the fuel of gas generator are the independent variables to control engine thrust, engine mixture ratio and temperature of gas generator product gas. The analysis program is validated by comparing with the powerpack test results. The error range of compared variables is order of 4%. After comparison of tuning effectiveness it is turned out that the pressure drop at oxidizer pipe of gas generator and pressure drop at combustion chamber fuel pipe and the pressure drop at the fuel pipe of gas generator can effectively tune the thrust of engine, mixture ratio of engine and temperature of product gas from gas generator respectively.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

Adaptive Closed-Loop Power Control Algorithm in DS/CDMA system (DS/CDMA 시스템의 적응형 폐쇄루프 전력 제어 알고리즘)

  • 감두열;박상규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.383-390
    • /
    • 2000
  • In this paper, an adaptive power control algorithm in the DS/CDMA system is proposed. The currently used transmitter/receiver based on IS-95 and the radio propagation channel under mobile communication environments are modeled. Theses are the key features for the simulation to analyse the performance of power control. the distribution of the received SIR(signal to interference ratio)and the bit error probability are the required parameters for the performance analysis. Furthermore the influence of the power control command error on the above parameters are analyzed. By using the performance analysis of IS-95 and the occurrence of burst errors that is characteristic for wireless channels. the new power control algorithm is proposed. The proposed power control algorithm increases the SIR which results in a better service quality and an enhancement in the system capacity.

  • PDF

Infeed Control Algorithm of Sorting System Using Modified Trapezoidal Velocity Profiles

  • Kim, Ki Hak;Choi, Yong Hoon;Jung, Hoon
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.328-337
    • /
    • 2015
  • This paper applies acceleration/deceleration control-based velocity profiles to an infeed control algorithm for a cross-belt-type sorting system to improve the accuracy and performance of the system's infeed. The velocity profiles are of a trapezoidal shape and often have to be modified to ensure that parcels correctly synchronize with their intended carriers. Under the proposed method, an infeed line can handle up to 5,600 items/h, which indicates a 40% increase in performance in comparison with its existing handling rate of 4,000 items/h. This improvement in performance may lead to a reduction in the number of infeed lines required in a sorting system. The proposed infeed control algorithm is applied to a cross-belt-type sorting system (model name: SCS 1500) manufactured by Vanderlande Industries.

Decentralized Control of Multiple Agents for Optimizing Target Tracking Performance and Collision Avoidance (표적 추적 성능 최적화 및 충돌 회피를 위한 다수 에이전트 분산 제어)

  • Kim, Youngjoo;Bang, Hyochoong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.693-698
    • /
    • 2016
  • A decentralized control method is proposed to enable a group of robots to achieve maximum performance in multisensory target tracking while avoiding collision with the target. The decentralized control was designed based on navigation function formalism. The study showed that the multiple agent system converged to the positions providing the maximum performance by the decentralized controller, based on Lyapunov and Hessian theory. An exemplary simulation was given for a multiple agent system tracking a stationary target.

Robust Two Degree of Freedom $H_\infty$ Control for Uncertain Systems

  • Kang, Young-Jung;Kwon, Oh-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.355-359
    • /
    • 1993
  • This paper deals with the problem of robust TDF(Two Degree of Freedom) H$_{\infty}$ control design for a linear system with parameter uncertainty in the state space model. The uncertain system considered here is with the time-invariant norm-bounded parameter uncertainty in the state matrix. A TDF H$_{\infty}$ control design is presented which robustly stabilizes the plant, guarantees the robust H$_{\infty}$ performance and improves the tracking performance for the closed-loop system in the face of parameter uncertainty. It is shwon that a suitable stabilizing control law can be constructed in terms of a positive definite solution to a certain parameter-dependent algebraic Riccati equation and a good tracking performance can be constructed in terms of suitable feedforward control law.aw.

  • PDF