• 제목/요약/키워드: Performance Accuracy

Search Result 8,216, Processing Time 0.036 seconds

Development of New Benchmark and Benchmark-observation Method for Effective Performence Rating Training of Assembling and Machining Operations (조립작업과 기계가공작업의 수행도평가훈련을 위한 기본표준과 기본표준관측법의 개발)

  • 박성학;장영기
    • Journal of the Korean Professional Engineers Association
    • /
    • v.22 no.3
    • /
    • pp.5-13
    • /
    • 1989
  • A major problem of stopwatch time study is how to do for the accurate and consistent performance rating, which is one of the critical variables to determine the accuracy of work measurement and should be still dependent upon time observer's judgement. Therefore the time observer's ability for the performance rating is very important, and must be improved by correct training method and procedure. This paper developed a new benchmark and benchmark-observation method for the effective performance rating training of assembling and machining operations. The trainees' ability in the accuracy and consistency of the performance rating ,improved significantly after being trained by subject method. The percentage improvement in rating accuracy and consistency values was 34.7% and 49% respectively. In addition, benchmark-practice method for the performance rating training is not significant, so it is proofed that the skill of a certain operation is not important for the improvement of the rating ability.

  • PDF

A Study on Detection Performance Comparison of Bone Plates Using Parallel Convolution Neural Networks (병렬형 합성곱 신경망을 이용한 골절합용 판의 탐지 성능 비교에 관한 연구)

  • Lee, Song Yeon;Huh, Yong Jeong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.63-68
    • /
    • 2022
  • In this study, we produced defect detection models using parallel convolution neural networks. If convolution neural networks are constructed parallel type, the model's detection accuracy will increase and detection time will decrease. We produced parallel-type defect detection models using 4 types of convolutional algorithms. The performance of models was evaluated using evaluation indicators. The model's performance is detection accuracy and detection time. We compared the performance of each parallel model. The detection accuracy of the model using AlexNet is 97 % and the detection time is 0.3 seconds. We confirmed that when AlexNet algorithm is constructed parallel type, the model has the highest performance.

Performance Improvement of Fuzzy C-Means Clustering Algorithm by Optimized Early Stopping for Inhomogeneous Datasets

  • Chae-Rim Han;Sun-Jin Lee;Il-Gu Lee
    • Journal of information and communication convergence engineering
    • /
    • v.21 no.3
    • /
    • pp.198-207
    • /
    • 2023
  • Responding to changes in artificial intelligence models and the data environment is crucial for increasing data-learning accuracy and inference stability of industrial applications. A learning model that is overfitted to specific training data leads to poor learning performance and a deterioration in flexibility. Therefore, an early stopping technique is used to stop learning at an appropriate time. However, this technique does not consider the homogeneity and independence of the data collected by heterogeneous nodes in a differential network environment, thus resulting in low learning accuracy and degradation of system performance. In this study, the generalization performance of neural networks is maximized, whereas the effect of the homogeneity of datasets is minimized by achieving an accuracy of 99.7%. This corresponds to a decrease in delay time by a factor of 2.33 and improvement in performance by a factor of 2.5 compared with the conventional method.

A Determination of an Optimal Clustering Method Based on Data Characteristics

  • Kim, Jeong-Hun;Yoo, Kwan-Hee;Nasridinov, Aziz
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.8
    • /
    • pp.305-314
    • /
    • 2017
  • Clustering is a method that collects data objects into groups based on their similary. Performance of the state-of-the-art clustering methods is different according to the data characteristics. There have been numerous studies that performed experiments to compare the accuracy of the state-of-the-art clustering methods by applying various kinds of datasets. A common problem of these studies is that they only consider clustering algorithms that yield the most accurate results for a particular dataset. They do not consider what factors affect the execution time of each clustering method and how they are affected. Nevertheless, execution time is an important factor in clustering performance if there is no significant difference in accuracy. In order to solve the problems of the existing research, through a series of experiments using various types of datasets, we compare the accuracy of four representative clustering methods. In addition, we perform practical clustering performance comparisons by deriving time complexity and identifying factors that influences to its performance.

Design and Manufacture of Laser Tracking System for Measuring Position Accuracy of Robots (로봇의 위치 정밀도 측정을 위한 LTS의 설계 및 제작)

  • 황성호;이호길;최령락;송웅희;김진영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.434-434
    • /
    • 2000
  • It is the main problem to measure the position and orientation of a robot end effector for the calibration of robots. The calibration methods can be used as a tool to improve the accuracy of robots without change of the arm or control architecture of robots. But such calibration methods require the accurate measurements. Dynamic measurement of position and orientation Provides a solution of this problem and improves dynamic accuracy by dynamic calibration o( robots. This paper describes the development o( the laser tracking system capable of determining the static and dynamic performance of industrial robots. The structure and system components are presented and basic experimental results are included to demonstrate the instrument performance. The system can be applied to the remote controlled mobile robots as weil as the calibration of robots.

  • PDF

Evaluation of Seismic Performance for Bridge Structure Using Capacity Spectrum Method (역량스펙트럼법을 이용한 교량의 내진성능평가)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.75-80
    • /
    • 2000
  • Evaluation method of seismic performance has mainly used elastic spectrum analysis. This method has simplicity of analysis but deficiency of accuracy. And evaluation method of seismic performance using inelastic dynamic analysis reflects accurately inelasticity of material but hardly reflects site effects. This study suggested evaluation scheme of seismic performance for bridge structure using capacity spectrum method applied inelastic static analysis and standard design response spectrum of Korea Standard Specification for Highway Bridge. Two results, capacity spectrum method and inelastic dynamic analysis method, are very similar. As a result, this study appropriately supply both simplicity of analysis and accuracy of result.

  • PDF

Research into Improvement of Circular-interpolation Accuracy (원호보간정도 향상에 관한 연구)

  • 김태원
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.624-628
    • /
    • 2000
  • The performance of machine tools is qualified by many test procedures given by the national/international standards or respected organisations. Among them, test regarding circular-interpolation accuracy is getting to be one of the important acceptance tests at the production level. Machine tool systems are composed of many mechanical and electronical sub-systems so that it is not easy to improve dynamic performance by examining only one particular part. Instead, overall systematic approach encompassing all the contributing elements is necessary to achieve good results. In this study, measures taken in circular accuracy improvements will be explained case by case.

  • PDF

Development of Coreless Linear Motor (무철심형 리니어모터 개발)

  • 정재한
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.291-296
    • /
    • 2000
  • Liner DC motors are widely used for servo-actuator, which would be applied for semiconductor equipments and precise machining systems. we have been developed linear DC motor with high speed, acceleration and position accuracy. From performance test, the position accuracy. From performance test, the position and repeatability accuracy were able to be controlled with 10 ${\mu}{\textrm}{m}$ and $\pm$1 ${\mu}{\textrm}{m}$, respectively. The highest acceleration and speed were obtained 3 G and 2m/sec, respectively. Static thrust force was 270N, and then error was 25%.

  • PDF

New D/A Design Method for Improving Accuracy in High-Performance Test Equipment (고성능 장비의 정밀도 향상을 위한 새로운 D/A 설계기법)

  • Kim, Hyung-Jung;Chae, Soo-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.308-309
    • /
    • 2018
  • This paper proposes new D/A(Digital to Analog) Design method for improving accuracy in high-performance test equipment. The proposed new D/A design can improve accuracy of the equipment even with low-resolution D/A converters. The validity of proposed D/A design is verified by analysis and experiment.

  • PDF

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.