• Title/Summary/Keyword: Perforated muffler

Search Result 33, Processing Time 0.023 seconds

A Study on the Acoustic and Cavity-Tone in a Perforated Through-Tube Muffler (다공관 배기 소음기의 음향 모드와 공동음에 관한 연구)

  • Kwon, Y.P;Lee, D.H.;Oh, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.13-19
    • /
    • 1995
  • The objective of this study is do obtain the relationship between the acoustic mode and cavity tone induced in a perforated tube exhaust muffler. First, the modal frequency for the axisymmetric radial mode and the mode shape have been computed using the impedance model for the perforated tube. Then, experiment has been perfonned for the onset frequencies of the cavity tone for various design parameters and through-flow. The theoretically obtained modal frequencies are well consistent with the measured onset frequencies of the cavity tone, showing that the cavity tone is induced by the axisymmetric radial mode. And it is found that the modal frequency of a perforated tube muffler is much lower than that of a simple expansion chamber.

  • PDF

Modification of the Porosity of the Perforated Plate for the Improvement of Acoustic Attenuation Performance for Muffler (머플러의 소음성능 향상을 위한 다공판 공극률의 설계변경해석)

  • Bae, Kyeong-Won;Park, Jeong-Pil;Jeong, Weui-Bong;Ahn, Se-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.83-89
    • /
    • 2015
  • The transmission loss(TL) has been widely used as the acoustic performance index of industrial mufflers. Industrial mufflers usually consist of several partitions with perforated plate. In this study, firstly, the computational model for a typical industrial muffler was performed and validated by comparing with the experimental results. Secondly, the effects of the porosity of the perforated plates on the acoustical TL were investigated and the database of the tendencies were set up. Finally, on the basis of these tendencies, the modified muffler with better TL than conventional one could be suggested.

A study on the Acoustic Mode and Cavity-Tone in a Perforated Tube Muffler (다공형 소음기의 음향 모우드와 공동음에 관한 연구)

  • 권영필
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.17-20
    • /
    • 1993
  • The acoustic mode of a perforated tube muffler was investigated both theoretically and experimentally to explain the cavity-tones induced by through-flow. The cutoff frequencies for the axisymmetric modes were obtained and confirmed experimentally. It was found that the cutoff frequencies are decreased significantly by the perforated tube. The onset frequencies of the cavity-tones were compared with the cutoff frequencies of the acoustic mode and it was found that the cavity-tones are induced by the radial acoustic modes and their frequency stages are coincident with the discrete cutoff frequencies.

  • PDF

Development of a muffler for the super heavymachinery in the 70 ton class (70톤 급 초대형 중장비용 머플러 개발)

  • Lee, Shi-Bok;Lee, Won-Tae;Nam, Kyung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2557-2564
    • /
    • 2009
  • In this study, a muffler for the super heavy machinery in the 70 ton class is developed. Developing process relies on experimental and rule of thumb approach. Various muffler internal structures consisting of partition plates, perforated and non-perforated through pipes, and absorbent are tried and compared for the transmission loss performance. Based on the experimental results, the best combination and locations of the internal acoustic components which affects the muffler performance are determined.

A Numerical Study on the Flow Characteristics in the Catalytic Muffler with Different Inlet and Outlet Configurations (입구 및 출구 형상 변화에 따른 촉매 삽입형 머플러 내부의 유동 해석)

  • An, Tae Hyun;Lee, Seung Yeop;Park, Yun Beom;Kim, Man Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Lack of the space in many diesel vehicles make it difficult to design and install the catalytic muffler to reduce emissions. For this reason, inlet part of the catalytic muffler is made of L-type which has lower flow uniformity than conventional I-type, and catalytic muffler has complex internal structure by various insertions, which affect the flow uniformity and pressure drop of the systems. In this work, the flow characteristics such as flow uniformity and pressure drop have been numerically investigated by changing such various geometries as inlet shape, porosity, and outlet shape inside the muffler with the three-dimensional turbulent incompressible flow solver. Total 4 different cases are considered in order to find optimal configurations of the catalytic muffler in view of high flow uniformity and low pressure drop. The results show that Case 2 which has no induction cone and outlet perforated pipe has higher uniformity index and lower pressure drop than others considered in this work.

Study on NOx Reduction with Multi-Perforated Tube Geometry in Integrated Urea-SCR Muffler (촉매삽입형 Urea-SCR 머플러 다공튜브 형상변화에 따른 NOx 저감 특성에 관한 연구)

  • Moon, Namsoo;Lee, Sangkyoo;Ko, Sangchul;Lee, Jeekeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1017-1026
    • /
    • 2014
  • A multi-perforated tube is generally installed between the muffler inlet and in front of selective catalytic reduction (SCR) catalysts in the integrated urea-SCR muffler system in order to disperse the urea-water solution spray uniformly and to make better use of the SCR catalyst, which would result in an increase nitrogen oxide ($NO_x$) reduction efficiency and a decrease in the ammonia slip. The effects of the multi-perforated tube orifice area ratios on the internal flow characteristics were investigated analytically by using a general-purpose commercial software package. From the results, it was clarified that the multi-perforated tube geometry sensitively affected the generation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst. To verify the analytical results, engine tests were carried out in the ESC and ETC modes. Results of these tests indicated that the larger flow model in the longitudinal direction showed the highest NOx reduction efficiency, which was a good agreement with the analytical results.

Analysis of an internal flow with multi-perforated tube geometry in an integrated Urea-SCR muffler (다공튜브 형상변화에 따른 촉매 삽입형 Urea-SCR 머플러 내부유동 해석)

  • Moon, Namsoo;Lee, Sangkyoo;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.500-509
    • /
    • 2013
  • This study reports a numerical analysis of the internal flow characteristics of the integrated urea-SCR muffler system with the various geometries of the multi-perforated tube which is set up between the muffler inlet and in front of SCR catalysts. The multi-perforated tube is generally used to disperse uniformly the urea-water solution spray and to make better use of the SCR catalyst, resulting in the increased $NO_x$ reduction and decreased ammonia slip. The effects of the multi-perforated tube orifice area ratios on the velocity distributions in front of the SCR catalyst, which is ultimately quantified as the uniformity index, were investigated for the optimal muffler system design. The steady flow model was applied by using a general-purpose commercial software package. The air at the room temperature was used as a working fluid, instead of the exhaust gas and urea-water solution spray mixture. From the analysis results, it was clarified that the multi-perforated tube geometry sensitively affected to the formation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst.

Characteristics of Noise Attenuation with the Variation of Flow Condition and Hole Shape of Perforated Intruding Tues in Muffler (유동조건과 내부관 구명형상의 변화에 따른 소음기의 소음저감 특성)

  • Jung, Jin-Nyon;Kim, Won-Jin;Cho, Bum-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.87-93
    • /
    • 1999
  • To propose a useful modelling method for an actual muffler, the noise attenuation effects of muffler was investigated according to the flow condition and the hole shape of tubes. In this work, the finite element method was used to calculate the transmission loss of muffler, The noise attenuation characteristics of four different types of muffler in the hole shape of tubes were compared mutually to find a more simple equivalent model. Analytical results showed that the overall value of transmission loss increases and the peaks of transmission loss curve shift to the low frequency with mean flow for the given muffler, Also the noise attenuation characteristics of the equivalent model having the split holes is almost the same as those of the actual muffler having many circular holes.

  • PDF

A Study on the Transmission Loss and Back Pressure of Muffler Elements (소음기 구성요소의 소음 및 배압특성에 관한 연구)

  • Hwang, Won-Geol;Lee, Yu-Yeop;O, Jae-Eung;Kim, Gi-Se;Song, Yong-Hui;Yong-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.147-153
    • /
    • 2002
  • The exhaust muffler is designed to reduce the engine noise with the minimum back pressure. It is composed of several elements, and we chose the five types of muffler elements : expansion, extended, offset, reversal, and perforated type. These elements are modeled with I-DEAS, and the transmission loss is analyzed with SYSNOISE, and the back pressure with STAR-CD. We verified the numerical results of transmission loss and pressure loss by experiments for the case of extended muffler. We find a database with the numerical results, which can be used in the design of exhaust muffler in the field.

Study on a Prediction of Noise Attenuation Performance of Automotive Mufflers (자동차 소음기의 소음성능 예측에 관한 연구)

  • 양기영;황원걸;기창두
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.389-394
    • /
    • 1994
  • The lattice filter formed transfer function has the advantage of computer simulation in the analysis of muffler. The transfer function is derived by using z-transformation for perforated elements in through-flow, cross-flow and reverse-flow type. A computer program for the prediction of the performance of automotive mufflers is developed using the transfer functions for uniform tube, open termination, expansion element, perforated elements, etc. The analytical results are verified by comparing with the experimental results for the transmission loss of a muffer. The effect of geometric configuration change of the muffler was invesigated in order to improve the performance of noise attenuation.

  • PDF