A Study on Perceptual Evaluation of Noise Sources in Living Environment (생활소음의 감성적 평가에 관한 연구)

  • 전진용;구민우;조문재
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.443-448
    • /
    • 2001
  • The subjective unwantedness felt from the noise sources in living environment has been evaluated by investigating the limit of perceptual loudness of the noise. The noise limits were selected by the subjects. And the noises were analyzed to find out whether there is any correlation with Zwicker parameters and ACF/IACF factors. It seemed that the loudness of noise from vacuum cleaner does not affect its perceives noisiness. Traffic noise also seems to be less influential in annoyance rating. It was resealed that floor impact noise generated by bang machine is the most irritating noise that can be heard in residential buildings.

  • PDF

Human Sensitivity Responses to Vibrotactile Stimulation on the Hand : Measurement of Differential Thresholds (진동식 촉각 자극에 대한 손의 상대적 민감도 반응)

  • Lee, Seong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.1-12
    • /
    • 1999
  • This study investigated human operator's perceptual and psychophysical responses to vibrotactile stimulation on various parts of the hand. Using a small vibrotactile display, the effects of three mechanical parameters consisting vibrotactile stimulations, i.e., vibration frequency, pulse-width modulation duty cycle, and number of contactors, on differential thresholds were examined at five different loci of the hand. It was observed that differential threshold varies with vibration frequency and number of active contactors. Differential sensitivity was the greatest at the vibration frequency of 120 Hz. The differential sensitivity was not found to be affected by loci on the hand. The area of stimulation on the hand was also found to be significant in that the sensitivity increased with the number of active contactors. It should be noted that the conclusions from this study generally correspond to those from the previous study on the absolute sensitivity. which means that tactile sensitivity to vibrotactile stimulations can be controlled with a systematic and consistent passion for emulating normal everyday contact on human hands in teleoperation and virtual reality applications.

  • PDF

Human Sensitivity Responses to Vibrotactile Stimulation on the Hand : Measurement of Absolute Thresholds (진동식 촉각 자극에 대한 손의 절대 민감도 반응)

  • Lee, Seong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.1-10
    • /
    • 1998
  • The objective of this study is to investigate hwnan operator's perceptual and psychophysical responses to vibrotactile stimulation on various parts of the hand. Using a small vibrotactile display, five different loci of the hand along with two other mechanical parameters consisting vibrotactile stimulations, which are vibration frequency and number of active contactors, were examined for the effects on absolute thresholds. All test variables were found to have significant effects on thresholds. It was observed that absolute threshold is a function of vibration frequency and number of active contactors. Tactile sensitivity was the greatest at the vibration frequency of 240 Hz, and the fingertip was found to be the most sensitive locus on the hand. The area of stimulation on the hand was also found to be significant in that the sensitivity increased with the number of active contactors. The results of the study generally supported those of other previous studies. It should also be noted, however, that the conclusions from the study should be limited to the absolute sensitivity, not to the suprathreshold intensities of normal everyday contact with the hands.

  • PDF

The Optical Measurement and Quantitative Analysis of Algesia in Spodoptera litura Larva

  • Chen, Ying-Yun;Chang, Rong-Seng;Tsai, Mi-Yin;Chen, Der-Chin
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.169-174
    • /
    • 2015
  • Muscle vibration measurement has long been an unique scientific study, in general, and the direct reaction of animals to feel pain (algesia), either from vascular or muscle contraction, is a complex perceptual experience. Thus this paper proposes a way to measure animal algesia quantitatively, by measuring the changes in muscle vibration due to a pinprick on the surface of the skin of a Spodoptera litura larva. Using the laser optical triangulation measurement principle, along with a CMOS image sensor, linear laser, software analysis, and other tools, we quantify the subtle object point displacement, with a precision of up to $10{\mu}m$, for our chosen Spodoptera litura larva animal model, in which it is not easy to identify the tiny changes in muscle contraction dynamics with the naked eye. We inject different concentrations of formalin reagent (empty needle, 12% formalin, and 37% formalin) to obtain a variety of different muscle vibration frequencies as the experimental results. Because of the high concentrations of reagent applied, we see a high frequency shift of muscle vibration, which can be presented as pain indices, so that the algesia can be quantified.

Evaluation of heavy-weight impact sounds generated by impact ball through classification (주파수 특성 분류를 통한 임팩트 볼 중량충격음의 주관적 평가)

  • Kim, Jae-Ho;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1142-1146
    • /
    • 2007
  • In this studies, subjective evaluation of heavy-weight floor impact sound through classification was conducted. Heavyweight impact sounds generated by an impact ball were recorded through dummy heads in apartment buildings. The recordings were classified according to the frequency characteristics of the floor impact sounds which are influenced by the floor structure with different boundary conditions and composite materials. The characteristics of the floor impact noise were investigated by paired comparison tests and semantic differential tests. Sound sources for auditory experiment were selected based on the actual noise levels with perceptual level differences. The results showed that roughness and fluctuation strength as well as loudness of the heavy-weight impact noise had a major effect on annoyance.

  • PDF

Subjective Evaluation of The Noise in Residential and Working Environment (주거 및 사무환경소음에 대한 주관적 평가)

  • 전진용;김경호;정정호;조문재
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.114-119
    • /
    • 2001
  • The subjective unwantedness felt from the noise sources in living and office environment has been evaluated by investgating the upper/lower limit of perceptual loudness of the noise. The limits were selected by the subject and the noise sources were analyzed to find out whether there is any correlation with Zwicker parpmeters and ACF fastors. It was found that the loudness of vacuum cleaner noise does not influence its perceived noiseness. Noises implicated in human such as floor walking noise and talking sound, are the most irritating noise in office environment.

  • PDF

The Effects of Vocal Relaxation Training on Voice Improvement of Children with Vocal Nodules (성대접촉이완훈련이 성대결절아동의 음성개선에 미치는 효과)

  • Han, Ji Eun;Seong, Cheol Jae
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.147-154
    • /
    • 2012
  • The purpose of this study is to examine the effect of voice improvement when vocal training, which relaxes the vocal contact, is applied to children with vocal nodules. Subjects included 20 5- to 12-year-old boys with vocal nodules in Otolaryngology and for whom voice therapy had been advised. The vocal therapy was conducted for 40 minutes per a week for a total of eight times. Results were evaluated by videostroboscopy, auditory-perceptual evaluation of GRBAS Scale, aerodynamic test, and acoustic analysis before and after therapy. As a result, first, the size of vocal nodules was reduced and the unstable pattern of vocal contact was improved. Glottic closure was increased and Phase symmetry was decreased during vocal vibration. Mucosal wave was increased and muscle tension of the larynx was reduced. Second, auditory-perceptual evaluation showed that subjects' overall quality of voice improved. GRBAS Scale Evaluation showed that the characteristics of the subjects' voice which were rough, breathy, and strained and breathy were reduced after therapy. Third, the measurements of acoustic parameters showed a statistically significant improvement. The fundamental frequency of the subejects' voice was increased and values of Jitter and Shimmer, NHR, [H1-H2] decreased. Fourth, the maximum phonation time of children was increased. These results imply that vocal relaxation training conducted in this study has a very positive effect to improve the voice of children with vocal nodules.

The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향)

  • Kim, Han-Su;Choi, Seung-Hee;Lim, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

Fast Convolution Method using Psycho-acoustic Filters in Sound Reverberator (잔향 생성기에서 심리 음향 필터를 이용한 고속 컨벌루션 방법)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1037-1041
    • /
    • 2007
  • With the advent of sound field simulator, many sound fields have been reproduced by obtaining the impulse responses of specific acoustic spaces like famous concert hall, opera house. This sound field reproduction has been done by the linear convolution operation between the sound input signal and the impulse response of certain acoustic space. However, the conventional finite impulse response based linear convolution operation always makes real-time implementation of sound field generator impossible due to the large amount of computational burden. This paper introduces the fast convolution method using perceptual redundancy in the processed signals, input audio signal and room impulse response. Temporal and spectral psycho-acoustic filters considering masking effects are implemented in the proposed convolution structure. It reduces the computational burden of convolution methods for realtime implementation of a sound field generator. The conventional convolutions are compared with the proposed one in views of computational burden and sound quality. In the proposed method, a considerable reduction in the computational burden was realized with acceptable changes in sound quality.

  • PDF

Study on the Motion Sickness Dose Values in Express Buses (고속 버스에서의 멀미발생 예측에 관한 연구)

  • 장한기;김승한;송치문;김성환;홍석인
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.548-554
    • /
    • 2003
  • This study alms to investigate the dynamic properties of express buses in the very low frequencies which cause motion sickness Incidence. Since passengers often use express buses for long distance traveling. it is a critical point whether the ride give rise to motion sickness or not. In the study accelerations at the three Points on the floor of the six test vehicles were measured during the driving at constant speeds. By applying the frequency weighting corves suggested in ISO 26.31-1, the Physical quantity of accelerations were changed into the perceptual amount used to judge quantitatively the incidence of motion sickness. Motion sickness dose values were calculated from the frequency weighted time history of acceleration signals, and compared between the vehicles, driving conditions. and the seat positions in the bus. During the 50 minutes' driving on the public road and high ways. the vomiting incidence ratios were seen to range from 0.4 to 0.8 %. which is equivalent to 2.4 to 4.8 % for 5 hours' driving. Unlike the very smooth road conditions considered in this work, motion sickness dose values encountered in real situations are expected to increase.