6MV 방사선의 물리학적 Penumbra (The Physical Penumbra of the 6MV X-ray)

  • 조문준;강위생
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.333-336
    • /
    • 1991
  • 충남대학교병원 치료방사선과내 설치되어 있는 6MV선형가속기를 이용하여 음영을 측정하여 다음과 같은 결과를 얻었다. 1) 조사면 크기가 커질수록 음영폭은 중가하였으며 10x10 Cm 이상의 조사면에서는 계산한 음영폭보다 측정치가 대개 크게 나타났다. 조사면이 커질수록 이 차이는 더욱 증가하였다. 2) 깊이가 증가하면 음영폭도 증가하였다. 3) $90\%\~20\%$의 음영폭이 $80\%\~20\%$의 음영폭보다 컸으며 조사면이 커지고, 깊이가 증가할 수록 이 차이는 더 커졌다.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.81-86
    • /
    • 1993
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing energy level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

허혈경계부의 감소를 보인 뇌졸중 환자에 대한 증례보고 (Study on the Ischemic penumbra concept in stroke patient by case study)

  • 고성규
    • 대한한방내과학회지
    • /
    • 제21권2호
    • /
    • pp.341-348
    • /
    • 2000
  • I have treated one ischemic stroke patient in acute stage with Seonghyangjeonggi-san, and observed remarkable reduction of the size ischemic portion in brain CT, notable improved motor power of patient. So I report this case of stroke patint. The ischemic penumbra, simply stated, is the part of the brain that is sandwiched brain regions committed to die and those that receive enough blood to communicate. Therefore, it is ischemic brain tissue that has just enough to communicte and function. The life expectancy of the penumbrais short. Although the penumbra is an elegant concept, in practice, it has been a difficult one to exploit. Up to now, a lot of research worker have tried to develop the method to make a accurate diagnosis. and then we know that PET and Xenon CT is available for the diagnosis for the ischemic penumbra. But those are not perfect to diagnose of penumbra. The case in my case report was confirmed as ischemic penumbra with CT. I know that CT is not prefect to diagnose penumbra, but I just want to raise the interest in penumbra of oriental medicine researcher and my report will be benificial to the penumbra researcher.

  • PDF

Penumbra Effect on Integral Absorbed Dose in Co-60 Teletherapy

  • Moon, Philip S.
    • Nuclear Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.87-93
    • /
    • 1973
  • Co-60원격치료장치에 장진된 Co-60 선원의 크기 때문에 Co-60원격치료시 치료부위에 반영부분이 생기게 되어 불필요한 방사선조사를 받게된다. 반영부분에서의 흡수적 산선량을 계산할 수 있는 식을 실험적으로 유도하였고, 실재로 Co-60원격치료에서 사용되는 조건을 실험식에 대입하여 반영의 크기가 흡수적산선랑에 미치는 영향을 연구해 보았다. 선원과 표피간의 거리가 크면 클수록 반영부분의 흡수적산선량은 커지고, 선원의 직경이 크면 클수록 반영부분의 흡수적산선량이 커진다. 선원과 피부간의 거리가 커지는데 따라, 어떤 경우에는 반영부분의 흡수적산선량이 치료부분의 흡수적산선량의 수배가 될 때도 있음을 알았다. 따라서 Co-60원격치료시에는 반영효과를 고려에 넣어 불필요한 방사선조사를 피하도록 하여야 하겠다.

  • PDF

p53 Protein Expression Area as a Molecular Penumbra of Focal Cerebral Infarction in Rats

  • Hong, Hyun-Jong;Park, Seung-Won;Kim, Young-Baeg;Min, Byung-Kook;Hwang, Sung-Nam;Suk, Jong-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.293-298
    • /
    • 2005
  • Objective : The authors investigate the spatial characteristics of apoptotic genes expressed around the focal cerebral infarction, and attempted to explain the penumbra with them. Methods : A delayed focal cerebral infarction was created in twelve adult Sprague-Dawley rats. We performed the immunohistochemical staining for the apoptosis, bcl-2 and p53 proteins and measured the local cerebral blood flow [CBF] at the infarction core area and peri-infarct area pre- and intra-operatively. The peri-infarct area was divided into six sectors by distance from the infarction border. Results : The size [$mm^2$] of apoptosis, bcl-2, and p53 areas were $3.1{\pm}1.2$, $4.7{\pm}2.1$, and $6.8{\pm}2.4$, respectively. Apoptosis, bcl-2 or p53 positive cells were concentrated at the peri-infarct area adjacent to the infarction core. Their numbers reduced peripherally, which was inversely proportional to the local CBF. The p53 area seems to overlap with and larger than the ischemic penumbra. Conclusion : The p53 positive area provides a substitutive method defining the penumbra under the molecular base of knowledge.

천마가 중대뇌동맥 폐쇄 흰쥐의 신경세포 자연사에 미치는 영향 (Effect of Gastrodiae Rhizoma on Apoptosis in Cerebral Infarction Induced by Middle Cerebral Artery Occlusion in Rats)

  • 윤유석;이종수
    • 한방재활의학과학회지
    • /
    • 제19권3호
    • /
    • pp.1-13
    • /
    • 2009
  • Objectives : This study evaluates neuroprotective effect of Gastrodiae Rhizoma on apoptosis in the cerebral infarct. Methods : Cerebral infarct was induced by the middle cerebral artery occlusion (MCAO) for 2 hours with intraluminal thread method in Sprague-Dawley rats. Then ethanol extract of Gastrodiae Rhizoma was administered orally for 3 days. Infarct area and volume were evaluated with TTC staining. Neuronal apoptosis was identified with TUNEL labeling. Apoptosis modulatory effect was observed with immunohistochemical Bax, Bcl-2, iNOS, and MMP-9 expressions in penumbra. Results : 1. Ethanol extract of Gastrodiae Rhizoma reduced infarct size partly and volume significantly of in the MCAO rat brain. 2. Ethanol extract of Gastrodiae Rhizoma reduced TUNEL positive cell ratio in the penumbra of MCAO rat brain significantly. 3. Ethanol extract of Gastrodiae Rhizoma suppressed Bax, iNOS and MMP-9 expression in the penumbra of MCAO rat brain significantly. 4. Ethanol extract of Gastrodiae Rhizoma did not change Bcl-2 expression in the penumbra of MCAO rat brain. But expression ratio of Bcl-2 against Bax was increased in the Gastrodiae Rhizoma group. Conclusions : These results suggest that Gastrodiae Rhizoma plays an anti-apoptotic neuroprotective effect through suppression of Bax, iNOS, and MMP-9 expressions and relative up-regulation of Bcl-2 in the ischemic brain tissue.

양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구 (Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case)

  • 김재원;심진섭;장요종;강동윤;최계숙
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.47-51
    • /
    • 2010
  • 목 적: 고 에너지 양성자치료에 있어서 Air gap (환자와 Beam 사출구 사이의 거리)의 변화는 Lateral Penumbra의 증가로 불필요한 조사야를 형성할 수 있고, 치료부위에서 최대선량 증가와 최소선량 감소로 선량분포의 균질성을 저하시킬 수 있다. 이에 Air gap 변화에 따른 선량분포에 대해 비교, 연구해 보고자 한다. 대상 및 방법: 본원에서 양성자치료를 받은 Lung, Liver 환자 6명을 선정하여 크기가 다른 조사야 A와 조사야 B에서 Air gap을 2, 4, 6, 8, 10 cm로 설정하여 Proton external beam planning system을 통해 치료계획을 세웠다. Air gap에 따른 Lateral Penumbra 영역 및 DVH (Dose Volume Histogram)를 비교하고 PCTV영역의 최대선량 및 최소선량 값을 비교하였다. 또한 PCTV내에 선량의 균질성을 알기 위하여 Homogeneity index값을 비교, 분석하였다. 결 과: 각각의 조사야에서 Air gap의 변화(2, 4, 6, 8, 10 cm)에 따른 Lateral Penumbra영역을 분석한 결과 조사야 A에서 Air gap 2~10 cm변화에 따라 평균 1.36~1.75 cm까지 약 28.7%가 지속적으로 증가하였고 조사야 B에서 평균 1.36~1.79 cm까지 약 31.6%가 지속적으로 증가하였다. DVH를 분석한 결과 최대선량의 상대선량 백분율은 Air gap 2~10 cm일 때 평균 108.1%에서 평균 110.3%까지 약 2.03%가 지속적으로 증가하였고 최소선량의 상대선량 백분율은 평균 93.9%에서 평균 90.8%까지 약 3.31%가 지속적으로 감소하였다. Homogeneity index값은 평균 Air gap 2~10 cm까지 1.09~2.6으로 2배 이상 증가하였다. 결 론: 양성자 치료에 있어서 Air gap이 증가함에 따라 Lateral Penumbra 영역이 증가함을 알 수 있었고, 치료부위에서 최대선량 값의 증가와 최소선량 값의 감소로 인하여 Homogeneity index값이 증가함으로써 PCTV내에 Beam의 균질성이 떨어지는 것을 알 수 있었다. 이에 추후 양성자치료시 Air gap을 줄이기 위한 노력이 필요할 것으로 사료된다.

  • PDF

소조사면 전량분포의 특성에 관한 고찰 (Study on the beam properties of small field sizes)

  • 조정희;이상규;안승권;박재일
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2004
  • 목적 : 본 연구의 목적은 소조사면의 선량특성을 측정하며 콜리메이터의 위치에 따른 반음영의 변화와 중심선량의 분포양상을 측정하며 측외측정선량점의 변화에 따른 선량분포의 특성을 측정하여 최근 대두되고 있는 소조사면 방사선치료에 유용한 정보를 제공하는데 그 목적이 있다. 대상 및 방법 : 지멘스의 Primart 선형가속기의 6MV에너지를 이용하였으며 측정은 Farmer chamber와 Pinpoint chamber를 이용하여 심부선량율과 beam profile, 중심출력선량의 변화를 측정하였다. 중심선속의 변화에 따른 에너지의 특성과 반음영의 변화를 외측으로 2cm 간격으로 측정하였다. 측정은 $1{\times}1cm,\;3{\times}3cm,\;5{\times}5cm,\;10{\times}10cm$에서 측정하였으며 결과는 표준조건하의 측정값과 비교, 분석하였다. 결과 : Farmer chamber와 Pinpoint chamber를 이용해 $1{\times}1cm$, 10cm깊이에서 측정한 결과 두 측정기간에 소조사면에서는 $30\%$ 이상의 차이를 보였으며 조사면의 크기가 증가함에 따라 두 측정기간의 차이는 급격히 감소했다. 측외측정점의 변화에 따른 선량분포는 큰 차이가 없었으나 조사야의 크기가 감소함에 따라 $1{\times}1cm$에서는 약 $13\%$의 차이를 보여 조사야 크기에 따른 변화가 큰 것으로 측정되었다. 전체조사면에서 반음영이 차지하는 비율도 조사면이 적어짐에 따라 높게 나타났으며 $1{\times}1cm$의 조사면에서는 약 $50\%$가 반음영이 점유하는 것으로 측정되었다. 결론 : 세기조절방사선 치료를 위해서는 각기 다른 에너지 분포를 갖는 여러 각도에서 다수의 조사면를 필요로 하며 여러 복잡한 인자들이 관여하게 된다. 여러 인자들 중에서도 콜리메이터의 형태 및 위치에 따른 출력선량의 변화 양상을 정확히 측정하는 것은 매우 중요하다. 실험결과에서도 알 수 있듯이 측정깊이와 조사면의 크기 및 측정기의 종류에 따른 측정값의 변화가 매우 크게 나타나므로 양질의 세기조절방사선 치료를 제공하기 위해서는 특히 소조사면의 선량분포에 대한 특성을 정확히 측정하는 것이 매우 중요하다.

  • PDF

코발트-60의 조사야(照射野) 변형(變形) 및 반음영(半陰影) 차폐(遮蔽)효과에 따른 선량분포(線量分布)에 관한 연구(硏究) (A Study on the Dose Distribution of Various Field and Penumbra Shield in the Telecobalt-60)

  • 김영일;이혜경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.71-72
    • /
    • 1985
  • This study was performed on the dose distribution of various field size and the effect of penumbra shield in the telecobalt unit. The results obtained are as follows. 1. Errors of the light and ${\gamma}-ray$ field size was below the regulation as 0.52 percentage. 2. The coefficient of field area was increased with the larger field area, and this coefficient was showed the more difference in larger SSD. 3. The rectangular field areas, which were described by level of the same percentage depth does, were decreased with the more elongation factor. At the same elongation factor, the compensating factor was decreased with the larger field size. 4. The lead block or extension collimator was able to shield r-ray exposure of outside field size from 50 to 80 percentage. 5. On the matching adjacent fields, while the gap between beam edges are contacted, that overlapped beam edges indicated up to 140 percentage, and while the gap was 1 cm, it could be reduced to 90 Percentage. The lead-libocking on the overlapped area was more effective to lower dose, as 80 percentage in this case. 6. Percentage depth dose of various trimming field sizes were increased linearlly according to area 1 perimeter size, but the center split field size did not maintain linearlly.

  • PDF