• Title/Summary/Keyword: Penetration test

Search Result 1,524, Processing Time 0.037 seconds

Analysis of load-settlement behaviour of shallow foundations in saturated clays based on CPT and DPT tests

  • Mir, Mouna;Bouafia, Ali;Rahmani, Khaled;Aouali, Nawel
    • Geomechanics and Engineering
    • /
    • v.13 no.1
    • /
    • pp.119-139
    • /
    • 2017
  • Static Penetration Test (CPT) and Dynamic Penetration Test (DPT) are commonly used in-situ tests in a routine geotechnical investigation. Besides their use for qualitative investigation (lithology, homogeneity and spatial variability), they are used as practical tools of geotechnical characterization (resistance to the penetration, soil rigidity) and modern foundation design as well. The paper aims at presenting the results of an extensive research work on the evaluation of the 1D primary consolidation settlement of saturated clayey soils on the basis of the CPT or DPT tests. The work is based on an analysis of the correlations between the tip resistance to penetration measured in these tests and the parameters of compressibility measured by the compressibility oedometer test, through a local geotechnical database in the northern Algeria. Such an analysis led to the proposal of two methods of calculation of the settlement, one based on the CPT test and the other one on the DPT. The comparison between the predicted settlements and those computed on the basis of the oedometer test showed a good agreement which demonstrate the possbility to use the CPT and DPT tests as reliable tools of computation of foundation settlements in clayey soils.

Evaluation of Chloride Ion Penetration Resistance of Coal Gasification Slag Replaced Concrete (석탄가스화 용융 슬래그 치환 콘크리트의 염화이온 침투 저항성 검토)

  • Cho, Hyeon-Seo;Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.166-167
    • /
    • 2019
  • In this study, to test the performance of concrete used as a concrete admixture as a recycling method of CGS, gypsum was mixed and the chloride ion penetration resistance test of CGS and BFS substituted concrete was conducted. As a result, it was found that without gypsum type test specimen, the CGS sustituted test specimens had lower chloride ion penetration resistance than the BFS substituted specimens. When gypsum was added, it was confirmed that the chloride ion penetration resistance was poor regardless of the type of admixture. In addition, it was confirmed that both admixtures were less resistant to chloride ion penetration than OPC, regardless of the presence of gypsum. However, considering the uneven quality variation of coal, which greatly affects the quality of CGS, further research is needed.

  • PDF

Evaluation of Soil Properties using Pressuremeter Test (공내재하시험을 이용한 지반정수 평가)

  • 한상연;장서만;전성곤;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

A Study on the high velocity impact behavior of titanium alloy by PVD method (PVD처리한 티타늄 합금의 고속충격 거동에 관한 연구)

  • Sohn, Se-Won;Lee, Doo-Sung;Hong, Sung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.567-572
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of Titanium alloy laminates and nitrified Titanium alloy laminates which were treated by PVD(Physical Vapor Deposition) method, ballistic tests were conducted. Evaporation, sputtering, and ion plating are three kinds of PVD method. In this research, Ion plating was used to achieve higher surface hardness and surface hardness test were conducted using a Micro vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit($V_{50}$), a statistical velocity with 50% probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_{50}$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ test with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration, and penetration modes of Titanium alloy laminates are compared to those of nitrified Titanium alloy laminates.

  • PDF

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

The Correlation Analysis between Dynamic Cone Penetration Test and Plate Loading Test Results for Evaluation of Dam Conditions (제체 상태 평가를 위한 동적 콘 관입시험과 평판재하시험 결과의 상관관계 분석)

  • Jung, Young-Hoon;Kim, Seongmin;Lim, Jeong-yeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.4
    • /
    • pp.33-38
    • /
    • 2018
  • The internal erosion due to poor compaction of the material was the main cause of collapse of the embankment in Korea. The assessment of the compaction state of the dam body was a very important check in the safety diagnosis of the embankment. In this study, the correlation between dynamic cone penetration test and plate loading test which is the most typical compaction evaluation technique was analyzed to verify the applicability of the dynamic cone penetration test in evaluating the compaction state of the dam body. The standard penetration tests were carried out six times to define soil properties and depth of the test site. The spatial distributions were obtained by the Kriging method after 15 times of plate loading tests and 47 times of dynamic cone penetration tests. The Pearson correlation coefficient between the spatial distribution of the plate loading test and the dynamic cone penetration test spatial distribution at the constant penetration depth was calculated. The load distribution in the plate loading test and the blow counts at penetration depths of 5 cm, 10 cm and 15 cm in the dynamic cone penetration test showed a weak positive correlation.

Application of Penetration in Fall Cone Test to Estimate Relative Density with Variation of Water Content for Sand (함수비를 고려한 모래의 상대밀도 추정을 위한 Fall Cone 관입량의 적용)

  • Choi, Woo-Seok;Son, Young-Hwan;Park, Jae-Sung;Noh, Soo-Kack;Bong, Tae-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.69-77
    • /
    • 2012
  • Relative density, used to express dynamics condition of sand quantitatively, is measured by RI Test, Standard Penetration Test and Cone Penetration Test. Each measurement method has demerits, which is complicated or needs a specific analysis instrument and an analysis of expert. Also the ground is in wet condition commonly because of an unsaturated zone between a saturated zone and a surface, so the behaviour of the ground has different engineering properties unlike the dry ground and it diminishes accuracy of measuring relative density. In this study, the correlation between relative density and penetration of fall cone test in dry condition and wet condition with variation of water content was analyzed and a simple measuring method for relative density was suggested. As a result, there were difference of penetration between dry sands and wet sands, the correlation between relative density and penetration showed linear expression and relative density could be measured by the linear relation.

A Study on the Evaluation Method for Penetration Test Method and Procedures (모의 침투 테스트 방법 및 절차의 평가 방법에 관한 연구)

  • Kang, Yong-Suk;Choe, Guk-Hyeon;Shin, Yong-Tae;Kim, Jong-Hee;Kim, Jong-Bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.230-233
    • /
    • 2014
  • Latest Inforamtion security threats and risks change very rapidly, and there to strengthen the security level of the major companies and organizations are diversified attack to respond to a penetration test conducted. Penetration test(PenTest) is safer for the purpose of looking for vulnerabilities in computer systems by taking advantage of vulnerabilities discovered in the same way as a hacker attack. How to make a security vulnerability could be exploited by attempting to attack show. On the other hand, many security companies are testing in a variety of ways to be penetrated. However, penetration testing to evaluate the strength and reliability has not performed yet. Therefore, in this study, Penetration testing to validate and present a reliable method of evaluation. In this study, penetration testing, assessment information to provide the evaluation results are more reliable. And, as a result, efficient penetration test is expected to be possible.

  • PDF

A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge (생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구)

  • Seon, Yun-Suk;Choi, Su-Young;Kim, Meong-Ji;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

  • Llena, Carmen;Forner, Leopoldo;Cambralla, Raquel;Lozano, Adrian
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.143-148
    • /
    • 2015
  • Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.