• Title/Summary/Keyword: Penetration resistance test

Search Result 404, Processing Time 0.024 seconds

A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge (생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구)

  • Seon, Yun-Suk;Choi, Su-Young;Kim, Meong-Ji;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System (인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구)

  • Lee, Jung-Hoon;Seon, Yun-Suk;Kwak, Kyu Sung;Oh, Sang-Keu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

An Experimental Study on the Salt Damage Resistance of High Durable Concrete (고내구성콘크리트의 염해저항성에 관한 실험적 연구)

  • Yoon, Jai-Hwan;Jaung, Jae-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.3
    • /
    • pp.73-81
    • /
    • 2003
  • In this paper, salt damage resistance of high durable concrete was tested. High durable concrete was made by using low water cement ratio, chemical admixture called super-durable admixture and mineral admixtures such as fly-ash, ground granulated blast-furnace slag, silica fume. Two kinds of salt damage resistance test were carried out. One method is chloride ion penetration test(ASTM C1202), and the other one is depth of chloride penetration test in saline solution. Test results were as followers: 1) The depth of chloride ion penetration increased exponentially as water cement ratio was increased and time passed. 2) Super-durable admixture had little effect on the improvement of salt damage resistance of concrete. 3) Silica fume and ground granulated blast-furnace slag were effective on salt damage resistance because of pozzolanic reaction, but fly-ash had a little effect.

Evaluation of Chloride Ion Penetration Resistance of Coal Gasification Slag Replaced Concrete (석탄가스화 용융 슬래그 치환 콘크리트의 염화이온 침투 저항성 검토)

  • Cho, Hyeon-Seo;Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.166-167
    • /
    • 2019
  • In this study, to test the performance of concrete used as a concrete admixture as a recycling method of CGS, gypsum was mixed and the chloride ion penetration resistance test of CGS and BFS substituted concrete was conducted. As a result, it was found that without gypsum type test specimen, the CGS sustituted test specimens had lower chloride ion penetration resistance than the BFS substituted specimens. When gypsum was added, it was confirmed that the chloride ion penetration resistance was poor regardless of the type of admixture. In addition, it was confirmed that both admixtures were less resistant to chloride ion penetration than OPC, regardless of the presence of gypsum. However, considering the uneven quality variation of coal, which greatly affects the quality of CGS, further research is needed.

  • PDF

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.4
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs (옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Sun, Yoon-Suk;Kwon, Shi-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil (소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구)

  • Son, Moorak;Lee, Jaeyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.5-15
    • /
    • 2016
  • This study investigated both water content and penetration resistance of small cone of various clay soils that were made of Kaolinite and Bentonite with different mixing ratios and compared the results with those of the existing dynamic (Casagrande test) and static (fall cone test) tests directly. The comparison showed that the water content at the inflection point on a curve of water content and penetration resistance was very similar to the liquid limit from a fall cone test. The penetration resistance of small cone at the inflection point was 0.2 kPa, and it was ascertained that the water content at the inflection point represents a liquid limit of clay soils. From the study results, it was found that the penetration resistance of 0.2 kPa with the small cone can be an indicator of the liquid limit of clay soils in practice. Finally a test procedure to measure the liquid limit of clay soil based on a penetration resistance of small cone was proposed.

Evaluation of Applicability of penetrating-type Nano-Coat for Preventing Deterioration of Concrete (침투형 Nano-Coat를 이용한 콘크리트 열화 방지 적용성 평가)

  • Lee, Jun Hee;Kim, Jo Soon;Sim, Yang Mo;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.7-15
    • /
    • 2017
  • PURPOSES : Infiltration of moisture, polluted material, and deicer into concrete, accompanied by freeze and thaw can cause significant deterioration of concrete pavement. In order to protect concrete from deterioration, it is necessary to prevent the infiltration of these concrete external materials. The moisture-repellent agent, which is a surface treatment and maintenance material added to concrete structures to render them water resistant, has advantages such as prevention of water infiltration and security against air permeation. Nano-coat, which is referred to as silicon hydride, is typically used as a moisture-repellent agent. Therefore, in this study, an attempt is made to use penetration-type Nano-coat as an alternative in order to evaluate its applicability through environmental resistance tests. METHODS : This study aimed to evaluate the applicability of penetration-type Nano-coat, which can provide water repellency to concrete, in concrete pavements, through various environmental resistance tests such as freezing and thawing resistance, chloride ion penetration resistance, and surface scaling resistance tests. The applicability of penetration-type Nano-coat was demonstrated based on the specification of KS F 2711, KS F 2456, and ASTM C 672. RESULTS :In the case of penetration-type Nano-coat applied on sound concrete, an increase in concrete durability was demonstrated by the negligible chloride ion penetrability and the absence of scaling, as revealed by visual observation of the surface, after 50 cycles of scaling resistance test. In addition, test result of the application of penetration-type Nano-coat on deteriorated concrete established that concrete surface pretreated by grinding provided improved durability than non-treated concrete. CONCLUSIONS :This study indicates that penetration-type Nano-coat is applicable as an effective alternative, to increase the durability of concrete structures. In addition, it was known that pretreatment of deteriorated concrete surface, such as grinding, is required to improve the long-term performance of concrete pavement.

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

A Study on the Determination of Depth of Soft Ground by Cone Resistance (피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구)

  • 신윤섭;김민철;김연정;김영웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF