• 제목/요약/키워드: Pediatric Chest examination

검색결과 36건 처리시간 0.01초

이물질 섭취 및 흡인 소아환자의 엑스선 영상 평가 (Evaluation of Radiography of Ingested and Aspirated Foreign Bodies in Pediatric Patients)

  • 권대철;최지원
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.291-295
    • /
    • 2018
  • The purpose of this study was to introduce the radiography for the natural course and clinical diagnosis of foreign body ingestion and aspiration, to help diagnosis and treatment, to evaluate the accuracy of radiographic images of pediatric patients. A 2 to 7 year-old patient who ingested a foreign body was ingested and aspirated with foreign substances such as coin, cloth pin, earring, baduk stone, and hairpins, and chest and abdomen of the plain radiography. The pediatric patient who ingested and aspirated the foreign body of the coins, the clothespins, the earrings, the stones, and the hairpins were examined by chest and abdomen of the plain radiography and fluoroscopic images. The radiography examination can be combined to effectively cope with the treatment and the treatment of the foreign substance removal. It can be applied to the diagnosis of foreign body in pediatric patient's clinic and appropriate treatment and treatment direction.

소아의 흉벽에서 진단된 평활근육종 1례 (Primary leiomyosarcoma of the chest wall in a child : a case report)

  • 최재혁;정찬욱;이미정
    • Clinical and Experimental Pediatrics
    • /
    • 제51권1호
    • /
    • pp.98-101
    • /
    • 2008
  • 평활근육종은 중간엽세포 기원의 평활근 분화를 보이는 연부조직육종으로 소아에서는 전체 연부조직육종의 2% 이하의 발생률을 보이는 매우 드문 질환이다. 특히 흉벽의 평활근육종은 더욱 드물다. 저자들은 우연히 발견된 흉벽 종양을 방사선학적 검사로 골연골종으로 추측하여 완전절제술을 실시하였고, 조직검사 결과 저등급 평활근육종으로 진단된 1례가 있어 보고하는 바이다.

소아 흉부촬영 시 나이와 체격에 따른 입사피부선량 (Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography)

  • 신귀순;민기열;김두한;이광재;박지환;이귀원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.327-334
    • /
    • 2010
  • 전리방사선의 피폭에 의한 암 유발확률은 소아가 성인에 비해 크기 때문에 소아 X선 검사 시의 환자선량을 정확히 파악하는 일은 중요하다. 그러나 우리나라는 소아 환자선량에 대한 연구가 활발하지 않다. 그러므로 본 연구에서는 7세 미만 소아를 대상으로 전리함을 이용하여 흉부검사 시의 입사피부선량(entrance skin dose, ESD)을 측정하여 나이, 키, 체중, 가슴두께와 ESD의 관계를 비교한 결과는 다음과 같았다. 소아는 나이에 따라서 키, 체중 및 가슴두께가 비슷한 양상으로 증가하므로, 흉부촬영 시 측정하기 힘든 가슴두께 대신에 나이에 따라서 촬영조건을 설정해도 무방함을 알 수 있었다. 2세 미만 소아의 흉부 A-P 검사 시, kVp는 A병원에서 더 높았으나, mAs는 반대로 B병원에서 높아, ESD 값이 B병원에서 약 1.7배 높았다. 그러나 4세 이상 소아의 흉부 P-A 검사 시에는 mAs는 같았고 kVp는 B 병원에서 7 kVp 높았으나, ESD값은 FID가 먼 B병원(180 cm)에서보다 더 가까운 A병원(130 cm)에서 1.4배 정도 높았다. 또한 같은 나이라도 A-P가 P-A보다 ESD값이 높았다. 나이별에 따른 ESD값을 보면, 1세 미만은 $154{\mu}Gy$, 1세에서 4세 미만은 $194{\mu}Gy$, 4세에서 7세 미만은 $138{\mu}Gy$으로 나타났다. 이 값은 일본의 JART의 권고량($200{\mu}Gy$)보다 낮으나, EC(유럽위원회)나 영국의 NRPB의 권고량보다 높으며, 2009년 12월에 식품의약품안전평가원에 제출된 용역보고서의 진단참고준위(5세 소아에서의 중간값이 $100{\mu}Gy$)보다 높다. 결론적으로 ESD는 X선장치 시스템의 차이보다는 방사선사의 경험적 실행에 의한 촬영조건의 차이에 의해서 크게 달라짐을 알 수 있었으며, 또한 나이가 많다고 더 많은 선량을 받는 것은 아니다. 따라서 나이에 따른 소아의 적정 참고준위의 확립과 점진적인 환자선량의 저감화가 반드시 필요하다.

비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구 (Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure)

  • 김훈;김용근;김준년;위승현;박은경;채명준;백부길;김은혜;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.

Analysis of clinical characteristics and causes of chest pain in children and adolescents

  • Chun, Ji Hye;Kim, Tae Hyeong;Han, Mi Young;Kim, Na Yeon;Yoon, Kyung Lim
    • Clinical and Experimental Pediatrics
    • /
    • 제58권11호
    • /
    • pp.440-445
    • /
    • 2015
  • Purpose: Chest pain is common in children and adolescents and is a reason for referral to pediatric cardiologists. Although most cases of chest pain in these age groups are benign and do not require treatment, timely diagnosis is important not to miss life-threatening diseases requiring prompt treatment. We investigated certain clinical characteristics that may be useful in the diagnosis of such critical diseases. Methods: Patient medical records between July 2006 and September 2013 were retrospectively examined. We included 517 patients who presented with chest pain to the Department of Pediatrics at Kyung Hee University Hospital in Gangdong. Results: Most cases of chest pain were idiopathic in origin (73.6%), followed by cases with respiratory (9.3%), musculoskeletal (8.8%), cardiac (3.8%), gastrointestinal (2.9%), and psychiatric (1.4%) causes. In 6 patients (1.2%) with air-leak syndrome including pneumothorax or pneumomediastinum, the pain was abrupt, continuous, and lasted for a short period of 1-2 days after onset in the older adolescents. Of the patients with cardiac pain, 13 had cardiac arrhythmias (65.0%), 6 had congenital heart diseases (30%), and 1 had coronary aneurysms caused by Kawasaki disease (5.0%). One patient with atrial flutter had only symptoms of syncope and chest pain. Conclusion: The abrupt, continuous chest pain of a short duration in the older children was characteristic of air-leak syndrome. In patients with pneumomediastinum, radiological diagnosis was difficult without careful examination. Combined syncope should not be neglected and further cardiac workup is essential in such patients.

X선 촬영 시 연령별 장기선량 차이 연구 (Investigation of organ dose difference of age phantoms for medical X-ray examinations)

  • 박상현;이춘식;김우란;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.35-42
    • /
    • 2003
  • 진단 X선 촬영에 의한 소아 및 성인의 장기 등가선량과 유효선량을 구하는 방법론을 개발하였다. 연령에 따른 체격의 차이가 방사선량 분포에 미치는 영향을 평가하기 위해, 식도를 포함한 4개 연령군의 MIRD형 수학적 모의피폭체를 제작하였다. 두 가지의 전형적인 진단 X선 절차인 흉부 PA와 복부 AP 진단 X선 촬영을 모사하여, 연령별 선량을 계산하였다. 흉부 PA 진단 X선 촬영절차에 의해서 환자들은 대략 0.03mSv의 유효선량을 피폭하는 것으로 나타났다. 복부 AP 진단 X선 촬영절차의 경우 연령에 따라서 0.4에서 1.7mSv의 유효선량을 받는 것으로 나타났다. 한정된 조사장을 갖는 방사선에 대해서 선량을 평가했기 때문에, 장기의 위치와 크기, 모양, 그리고 방사선이 입사하는 표면으로부터의 필이 등이 선량 계산에 상당한 영향을 미쳤다. 따라서 진단 X선의 조사장이나 선질의 조절 등을 통해 방호의 최적화를 위한 노력이 중요한 것으로 나타났다. 본 연구에서 개발된 선량계측 절차는 의료방사선 방호의 최적화를 위한 수단으로 활용될 수 있다.

선천성 식도열공탈장의 외과적 치험 1예 (Suegical treatment of congenital esophageal hiatus hernia)

  • 오봉석;김상형;이동준
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.399-404
    • /
    • 1983
  • In general, hiatal hernia is rare incidence among diaphragmatic hernia in Korea especially in pediatric group. Recently great interest in hiatal hernia has not led to common agreement concerning the pathophysiology, method of diagnosis, clinical picture, Indications, and type of treatment. At 1981 and 1983, two cases of congenital hiatal hernia [type I, III] were surgically treated,which surgical Intervention was modified Hill`s operation and gastropexy. Postoperatively, clinical and radiological examination were proved no regurgitation, no dysphagia and well passage of barium.

  • PDF

자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가 (Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device)

  • 권오영;이창훈;용금주;진선희;정다빈;허영철
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.1049-1056
    • /
    • 2021
  • 본 연구의 목적은 일반촬영용 호흡 동기화 장치를 개발하여 호흡 협조가 어려운 환자의 가슴 검사를 할 때 들숨의 재현성을 높이는 것이다. 공기압 센서를 이용하여 호흡 동기화 장치를 자체 제작(X-RSD)하였고, 심폐소생술용 마네킹에 벤틸레이터를 연결하여 공기를 주입하였다. 이때 주입한 공기의 양은 SkillReporting 장치를 이용하여 정량화하였다. 마네킹의 가슴에 X-RSD를 위치한 후 공기의 양을 200-700 cc까지 100 cc 씩 총 6 단계를 나눠서 검사하였다. 오차 평가는 총 80회씩 반복 측정하여 X-RSD의 민감도를 측정하였고 민감도는 100%로 매우 정교한 결과 값을 얻을 수 있었다. 이후 가슴 측면검사를 X-RSD를 보면서 검사한 영상과, 암맹 검사한 영상을 비교평가 하였고, X-RSD의 폐 용적이 암맹 검사보다 용적도 크게 측정되고, 편차도 적게 측정되었다. 종합적으로 X-RSD를 이용하면 협조가 어려운 환자의 가슴검사에 도움을 줄 수 있으며, 일반촬영의 재촬영률을 줄여 전체적인 피폭선량 감소에 기여가 가능할 것이라 사료된다.

소아에서 피하매몰 중심정맥포트가 전복된 사례에 대한 경험 - 2예 보고 - (Inversion of Implantable Central Venous Port in Children - 2 Cases Report -)

  • 최준영;김현영;정성은;박귀원;김우기
    • Advances in pediatric surgery
    • /
    • 제12권1호
    • /
    • pp.17-23
    • /
    • 2006
  • A 3-year-old girl with a primitive neuroectodermal tumor (PNET) and a 6-yearold girl with acute lymphoid leukemia were referred to us because of problems with their implantable central venous ports (Port-A-Cath$^{(R)}$). On physical examination, the ports were upside-down, so a needle could notbe inserted through the membrane of the port. Right lateral side view of the chest radiogram confirmed port inversion in both cases. At operation, the ports were inverted and the transfixing sutures were totally absorbed. The ports were rotated 180 degrees and anchoring sutures placed.

  • PDF

소아 흉부검사 시 격자 사용에 따른 영상 화질 평가 (Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination)

  • 정성훈;한범희;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.371-376
    • /
    • 2017
  • 소아의 경우 방사선의 감수성이 성인에 비하여 높고, 잠재적 피폭으로 인한 장해가 발생할 수 있으므로 피폭선량에 대해 관리가 요구된다. 이에 본 연구는 소아 흉부검사 시 산란선을 제거시켜주지만 피폭선량을 증가시키는 격자(Grid)의 사용 유, 무에 따른 영상과 거리와 조건의 변화에 따른 영상을 분석하여 소아 흉부검사에서 적정한 검사조건을 제시하고자 하였다. 연구방법은 Grid를 부착한 상태에서 100 cm, 180 cm에서 측정하였으며, kVp를 70. 90. 110으로 변화하여 측정하였다. 또한 Grid를 미부착한 상태에서 100 cm, 180 cm을 고정 시키고, 선량을 6, 8, 10 mAs로 변화시켜 측정하였으며, 측정항목은 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich를 측정하였다. kVp를 고정시켜 측정한 결과 초점-이미지 수용체간 거리가 100 cm일 때 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich가 모두 높게 나타났다. 또한, 선량(mAs)을 변화시켜 측정한 결과 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich에서 초점-이미지 수용체 간 거리 100 cm에서 높게 나타났다. 현재 국내에서 흉부검사는 일반적으로 180 cm으로 시행하고 있지만 본 연구결과에서는 소아의 흉부 검사 시 초점-이미지수용체간 거리가 100 cm일 때 영상평가에서 화질이 높게 평가되었다.