• Title/Summary/Keyword: Peak voltage detection method

Search Result 27, Processing Time 0.019 seconds

Determination of Water-Soluble Vitamins by Free Solution Capillary Electrophoresis (모세관전기영동을 이용한 수용성비타민의 분석)

  • Choi, One-Kyun;Jo, Jae-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.18-22
    • /
    • 1994
  • This study was designed to investigate the method of the simultaneous determination of water-soluble vitamins (thiamine, ascorbic acid, riboflavin, folic acid, cyanocobalamine, pyridoxin, nicotinic acid) by free soloution capillary electrophoresis. Factors affecting on the separation were pH of the buffer, applied voltage and temperature. On-column detection at 254 nm allowed accurate and reproducible determination of these compounds. All these compounds were separated within ca. 8 min with fused silica capillary at 20 kV.

  • PDF

Nondestructive Evaluation of Residual Life of 1Cr-1Mo-0.25V Steel by Reversible Magnetic Permeability

  • K. S. Ryu;S. H. Nahm;Kim, Y. I.;K. M. Yu;Kim, Y. B.;Y. Cho;D. Son
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.522-529
    • /
    • 2000
  • We present a new procedure to evaluate the residual life of 1Cr-1Mo-0.25V steel by reversible magnetic permeability. The method is based on the existence of the first harmonics in the differential magnetization around the coercive force. The apparatus is based on the detection of the voltage induced in a coil using a lock-in amplifier tuned to a frequency of the exciting one. Results obtained for the first harmonics and Vickers hardness on the aged samples show that the peak interval of reversible permeability and Vickers hardness decrease as ageing time increases. The correlation between Vickers hardness and the peak interval of the reversible permeability could well be used to evaluate the residual life of 1Cr-1Mo-0.25V steel, nondestructively.

  • PDF

An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode (Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기)

  • Yi, In-Je;Kim, Ju-Ho;Kang, Chi-Jung;Kim, Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

Capillary Electrophoretic Method for the Determination of (+)-Catechin, (-)-Epicatechin in Grape Seed Ethanol Extract (포도종실 에탄올 추출물에 함유된 (+)-카테킨, (-)-에피카테킨의 모세관 전기영동법에 의한 분석)

  • Choi, One-Kyun;Chung, Yang-Seop;Chung, Ha-Yull
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.513-518
    • /
    • 2005
  • Capillary electrophoresis (CE) method was developed to determine (+)-catechin and (-)-epicatechin contents in grape seed ethanol extract. CE separation was achieved using 100 mM phosphate and borate buffer at pH 6.0 as background electrolyte and fused silica capillary with 50 microns x 375 microns O.D. (effective length 20.0cm) maintained at $25^{\circ}C$. The applied voltage was 10kV, and detection was performed by DAD at 210 nm, Two catechins were well separated within 6 min with repeatability of <0.8% RSD for migration time and <2.0% RSD for peak area, and correlation coefficients higher than 0.994 were obtained from 58.0 to 174.0 mg/L with detection limit of 0.035 mg/L. Separated compounds were successfully determined. CE method was easy to handle and showed good reproducibility. CE method was compared with conventional coloring and HPLC methods, and main advantages of CE method were low amount of sample required, simple pre-sample treatment, good recovery rate, and short analysis time.

Electrochemical Immunosensor Based on the ZnO Nanorods Inside PDMS Channel for H7N9 Influenza Virus Detection (PDMS 채널 내부에 성장된 산화아연 나노막대를 이용한 H7N9 인플루엔자 바이러스 전기화학 면역센서)

  • Han, Ji-Hoon;Lee, Dongyoung;Pak, James Jungho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.278-283
    • /
    • 2014
  • In this study, we propose an immunosensor using zinc oxide nanorods (NRs) inside PDMS channel for detecting the influenza A virus subtype H7N9. ZnO with high isoelectric point (IEP, ~9.5) makes it suitable for immobilizing proteins with low IEP. In this proposed H7N9 immunosensor structure ZnO NRs were grown on the PDMS channel inner surface to immobilize H7N9 capture antibody. A sandwich enzyme-linked immunosorbent assay (ELISA) method with was used 3,3',5,5' tetramethylbenzidine (TMB) for detecting H7N9 influenza virus. The immunosensor was evaluated by amperometry at various H7N9 influenza antigen concentrations (1 pg/ml - 1 ng/ml). The redox peak voltage and current were measured by amperometry with ZnO NWs and without ZnO NWs inside PDMS channel. The measurement results of the H7N9 immunosensor showed that oxidation peak current of TMB at 0.25 V logarithmically increased from 2.3 to 3.8 uA as the H7N9 influenza antigen concentration changed from 1 pg/ml to 1 ng/ml. And then we demonstrated that ZnO NRs inside PDMS channel can improve the sensitivity of immunosensor to compare non-ZnO NRs inside PDMS channel.

Development of Flexible Glucose Measurement Sensor Based on Copper Nanocubes Electroplated Laser Induced Graphene Electrode (구리 나노 큐브를 전기 도금한 레이저 유도 그래핀 전극 기반의 글루코스 측정용 유연 센서 개발)

  • Kim, Geon-Jong;Kim, Taeheon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.413-418
    • /
    • 2018
  • In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. $CO_2$ laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were $15.6{\Omega}/{\Box}$ and $19.6{\Omega}/{\Box}$, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity ($1643.31{\mu}A/mM{\cdot}cm^2$), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to $30^{\circ}$, $90^{\circ}$, and $180^{\circ}$ and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat.