• Title/Summary/Keyword: Peak pressure

Search Result 1,452, Processing Time 0.022 seconds

The Effects of Gel-type Insole on Patients with Knee Osteoarthritis during Gait (겔-타입 인솔이 무릎 골관절염 환자의 보행에 미치는 영향)

  • Eun, Seon-Deok;Yu, Yeon-Joo;Shin, Hak-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • The purpose of this study was to investigate the biomechanical effects of wearing different type of insole shoes on gait characteristics in patients with knee osteoarthritis. Seven patients with knee osteoarthritis (Grade 3 & 4 by Kellgren & Lawrence) were participated in the study. They wore two different type of shoes (with Gel-type Insole: GIS, with Normal insole: NIS) during gait. Three dimensional cinematography and Ground Reaction Force(GRF) data were used to get the maximal value of horizontal distance between the center of pressure in GRF and knee joint center, GRF in mediolateral direction, peak value of GRF in frontal plane, vertical compressive force and adduction moment in knee joint. The results were as follows: The maximal value of horizontal distance between the center of pressure in GRF and knee joint center was smaller in GIS than NIS. The peak value of GRF in mediolateral direction was found in 30% of gait cycle, five subjects wearing GIS showed lower value of peak GRF in mediolateral direction than wearing NIS. The peak value of GRF in frontal plane and vertical compressive force in knee joint did not show any difference between GIS and NIS. The adduction moment in GIS decreased in the late stance of gait and the mean value of the adduction moment in GIS smaller than that in NIS. GIS may help to move quickly knee joint center to the center of pressure in GRF, therefore it may prevent increasing the adduction moment in knee joint.

Beneficial Cardiovascular Effects Of Hydroalcoholic Extract From Crocus Sativus In Hypertension Induced By Angiotensin II

  • Plangar, Abdolali Faramarzi;Anaeigoudari, Akbar;KhajaviRad, Abolfazl;Shafei, Mohammad Naser
    • Journal of Pharmacopuncture
    • /
    • v.22 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Objectives: Angiotensin II (AngII), a major product of renin-angiotensin system (RAS) has important role in induction of hypertension and antihypertensive effect of several medicinal plant was mediated by effect on this agent. Therefore, this study examined the possible effect of hydroalcoholic extract of Crocus sativus (C. sativus) on hypertension induced by AngII. Methods: Six groups (n = 6) of rats were used as follow: 1) Control, 2) AngII (300 ng/kg), 3) Losartan (Los, 10 mg/kg) + AngII and 4-6) C. sativus extract (10, 20 & 40 mg/kg,) + AngII. The femoral artery and vein were cannulated for recording cardiovascular parameters and drugs administration, respectively. All drugs were injected intravenously (i.v). Los and all doses of C. sativus injected 10 min before AngII. Systolic blood pressure (SBP), mean arterial blood pressure (MAP) and heart rate (HR) were recorded throughout the experiment and those peak changes (${\Delta}$) were calculated and compared to control and AngII. Results: AngII significantly increased ${\Delta}MAP$, ${\Delta}SBP$ and ${\Delta}HR$ than control (P < 0. 01 to P < 0.001) and these increments were significantly attenuated by Los. All doses of C. sativus significantly reduced peak ${\Delta}MAP$, ${\Delta}SBP$, and ${\Delta}HR$ than AngII group (P < 0. 05 to P < 0.001). In addition, peak ${\Delta}MAP$, ${\Delta}SBP$ in doses 10 and 20 were significant than Los + AngII group (P<0.05 to P< 0.01) but in dose 40 only MAP was significant (P<0.05). Peak ${\Delta}HR$ in all doses of C sativus was not significant than Los+ AngII. Conclusion: Regarding the improving effect of the C. sativus extract on AngII induced hypertension, it seems that this ameliorating effect partly mediated through inhibition of RAS.

The Study of the Mid-sole Wedge of Pronated Group on Maximum Force and Foot Pressure (중족부 Wedge 착용 시 회내 집단의 최대 힘과 족저압력 연구)

  • Lee, Jae-Ik;Lee, Hyo-Taek;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.337-344
    • /
    • 2010
  • This study was conducted on male college students with pronated foot to measure the foot pressure by having them wear three kinds of mid-sole wedge ($0^{\circ}$, $5^{\circ}$, $10^{\circ}$). Maximum force, foot contact area, mean pressure and peak pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding maximum force, there were statistically significant difference in the area 3 of the middle foot(p<.05). Regarding the foot contact area, it appeared broad in the outside area(1, 3, 5) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Mean pressure by foot area decreased in the inside of the foot according to mid-sole wedge, and there was statistically significant difference in the area 2 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Regarding the peak pressure by foot area, the pressure roughly decreased in the inside area(2, 4, 7) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1(p<.05), 2(p<.05) of the rear foot and the area 3 of the middle foot(p<.05).

The Effect of the Wedge Insole Angle of Supinated Group on Foot Contact Time, Foot Contact Area and Foot Pressure (회외족의 Wedge Insole 각에 따른 보행 시 접지 시간, 접지면적 및 족저압력의 비교)

  • Lee, Hyo-Taek;Kim, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.4
    • /
    • pp.508-515
    • /
    • 2010
  • This study was conducted on male college students with supinated foot to measure the foot pressure by having them wear three kinds of wedge insoles ($0^{\circ}$, $3.5^{\circ}$, $7^{\circ}$). Foot contact time, foot contact area, peak pressure and mean pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding foot contact time, there was no statistically significant difference by showing $0.69{\pm}0.004$ seconds at $3.5^{\circ}$ and $0.68{\pm}0.006$ seconds at $0^{\circ}$ and $7^{\circ}$. Regarding the foot contact area, it appeared broad in the inside area of the foot according to wedge insole, and there was statistically significant difference in the area 1 of the rear foot(p< .01) and the area 3 of the middle foot(p< .05). The peak pressure by foot area decreased in the outside of the foot according to wedge insole, while increasing in the inside of the foot. Among the areas, there was statistically significant in the area 2 of the rear foot (p< .01) and the area 3 of the middle foot (p< .05). Regarding the mean pressure by foot area, the pressure roughly increased in the inside area of the foot according to wedge insole, while decreasing in the outside of the foot.

Probabilistic estimation of fully coupled blasting pressure transmitted to rock mass II - Estimation of rise time - (암반에 전달된 밀장전 발파입력의 획률론적 예측 II - 최대압력 도달시간 예측을 중심으로 -)

  • Park, Bong-Ki;Lee, In-Mo;Kim, Sang-Gyun;Lee, Sang-Don;Cho, Kook-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.1
    • /
    • pp.25-40
    • /
    • 2004
  • The supersonic shock wave generated by fully coupled explosion will change into subsonic shock wave, plastic wave, and elastic wave consecutively as the wave propagates through rock mass. While the estimation of the blast-induced peak pressure was the main aim of the companion paper, this paper will concentrate on the estimation of the rise time of blast-induced pressure. The rise time can be expressed as a function of explosive density, isentropic exponent, detonation velocity, exponential coefficient of the peak pressure attenuation, dynamic yield stress, plastic wave velocity, elastic wave velocity, rock density, Hugoniot parameters, etc. Parametric analysis was performed to pinpoint the most influential parameter that affects the rise time and it was found that rock properties are more sensitive than explosive properties. The probabilistic distribution of the rise time is evaluated by the Rosenblueth'S point estimate method from the probabilistic distributions of explosive properties and rock properties. Numerical analysis was performed to figure out the effect of rock properties and explosive properties on the uncertainty of blast-induced vibration. Uncertainty analysis showed that uncertainty of rock properties constitutes the main portion of blast-induced vibration uncertainty rather than that of explosive properties. Numerical analysis also showed that the loading rate, which is the ratio of the peak blasting pressure to the rise time, is the main influential factor on blast-induced vibration. The loading rate is again more influenced by rock properties than by explosive properties.

  • PDF

Instability of Plunging Breaking Wave Impact on Inclined Cylinder (경사진 실린더에 작용하는 플런징 쇄파 충격력의 불안정성 고찰)

  • Hong, Key-Yong;Shin, Seung-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.4
    • /
    • pp.187-192
    • /
    • 2007
  • Impact on cylindrical surface caused by plunging breaking waves is investigated experimentally. The breaking waves are generated in a wave flume by decreasing the wave maker frequencies linearly and focusing the generated wave components at one specific location. The breaking wave packets are based on constant wave steepness spectrum. Three inclination angles of cylinder are applied to examine the effect of contact angle between cylinder and front surface of breaking waves. Also, the effect of cylinder diameter on pressure distribution and its peak value is investigated by adopting three cylinders with different diameters. The longitudinal location of cylinder is slightly moved in eight different points to find out a probable maximum value of impact pressure. The pressures and total force on cylinder surface are measured by piezo-electric pressure sensors and 3-components load cell with 30kHz sampling rate. The variation of peak impact pressures and forces is analyzed in terms of cylinder diameter, inclination angle and location. Also, the pressure distribution on cylindrical surface is examined. The cylinder location and surface position are more important parameters that govern the magnitude and shape of peak pressures, while the cylinder diameter and inclined angle are relatively insignificant. In a certain conditions, the impact phenomenon becomes very unstable which results in a large variation of measured valves in repeated runs.

  • PDF

Harmonic Peak Picking-based MVF Estimation for Improvement of HMM-based Speech Synthesis System Using TBE Model (TBE 모델을 사용하는 HMM 기반 음성합성기 성능 향상을 위한 하모닉 선택에 기반한 MVF 예측 방법)

  • Park, Jihoon;Hahn, Minsoo
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.79-86
    • /
    • 2012
  • In the two-band excitation (TBE) model, maximum voiced frequency (MVF) is the most important feature of the excitation parameter because the synthetic speech quality depends on MVF. Thus, this paper proposes an enhanced MVF estimation scheme based on the peak picking method. In the proposed scheme, the local peak and the peak lobe are picked from the spectrum of a linear predictive residual signal. The normalized distance between neighboring peak lobes is calculated and utilized as a feature to estimate MVF. Experimental results of both objective and subjective tests show that the proposed scheme improves synthetic speech quality compared with that of the conventional one.

A revised Hermite peak factor model for non-Gaussian wind pressures on high-rise buildings and comparison of methods

  • Dongmei Huang;Hongling Xie;Qiusheng Li
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.15-29
    • /
    • 2023
  • To better estimate the non-Gaussian extreme wind pressures for high-rise buildings, a data-driven revised Hermitetype peak factor estimation model is proposed in this papar. Subsequently, a comparative study on three types of methods, such as Hermite-type models, short-time estimate Gumbel method (STE), and new translated-peak-process method (TPP) is carried out. The investigations show that the proposed Hermite-type peak factor has better accuracy and applicability than the other Hermite-type models, and its absolute accuracy is slightly inferior to the STE and new TPP methods for non-Gaussian wind pressures by comparing with the observed values. Moreover, these methods generally overestimate the Gaussian wind pressures especially the STE.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.4 no.1
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

Evaluation of Foot Pressures and Subjective Discomfort Ratings associated with Sneakers, High Heels, and Kill Heels (운동화, 하이힐, 그리고 킬힐에 따른 족압과 주관적 불편도 평가)

  • Song, Jae-Woong;Kim, Sung-Ja;Lee, Ga-Hee;Song, Ki-Burm;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • Ten young females were participated in this study to investigate the effects of types of shoes (sneakers, high heels, kill heels), types of tasks (standing, walking floor, step up and down), and areas of foot (fore foot, middle foot, rear foot) on foot pressures as well as subjective discomfort ratings. Results showed that kill heels had the most discomfort shoes, followed by high heels and sneakers. Generally, as the heel was higher, the discomfort of foot increased. For the analyses of task types, generally discomfort ratings were highest for the step down and up, followed by walking floor and standing. Especially discomfort ratings of high heels and kill heels were more evident in case of step up and step down than standing and walking floor. Standing task was rated as the lowest levels of discomfort on users' foot. Peak and mean foot pressures were also evaluated in this study. The findings represented that there was no significant differences between types of shoes in both peak and mean foot pressures. The peak pressure (82.14kPa) and mean pressure (40.32kPa) for standing task were significantly lower than those of other tasks [walking floor (190.55kPa, 55.46kPa), step up (191.43kPa, 53.80kPa), and step down (200.66kPa, 52.62kPa)]. Generally discomfort ratings and peak/mean pressures associated with foot showed that fore foot had higher discomfort ratings as well as peak and mean pressures than middle and rear foots. In particularly, this trend was more obvious in case of high heels and kill heels. For the high heels and kill heels, the peak pressures of fore foot were 4.5~4.8 times and 2.3~2.5 times greater than that of middle foot and rear foot, respectively, whereas the peak pressures of fore foot were 2.9 times and 1.7 times greater than that of middle and rear foots, respectively, in case of sneakers.