• 제목/요약/키워드: Peak power reduction

검색결과 361건 처리시간 0.031초

Reduction of sidelobe levels in multicarrier radar signals via the fusion of hill patterns and geometric progression

  • Raghavendra, Channapatna Gopalkrishna;Prakash, Raghu Srivatsa Marasandra;Panemangalore, Vignesh Nayak
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.650-659
    • /
    • 2021
  • Multi-carrier waveforms have several advantages over single-carrier waveforms for radar communication. Employing multi-carrier complementary phase-coded (MCPC) waveforms in radar applications has recently attracted significant attention. MCPC radar signals take advantage of orthogonal frequency division multiplexing properties, and several authors have explored the use of MCPC signals and the difficulties associated with their implementation. The sidelobe level and peak-to-mean-envelope-power ratio (PMEPR) are the key issues that must be addressed to improve the performance of radar signals. We propose a scheme that applies pattern-based scaling and geometric progression methods to enhance sidelobe and PMEPR levels in MCPC radar signals. Numerical results demonstrate the improvement of sidelobe and PMEPR levels in the proposed scheme. Additionally, autocorrelations are obtained and analyzed by applying the proposed scheme in extensive simulation experiments.

Smooth Torque Speed Characteristic of Switched Reluctance Motors

  • Zeng, Hui;Chen, Zhe;Chen, Hao
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.341-350
    • /
    • 2014
  • The torque ripple of switched reluctance motors (SRMs) is the main disadvantage that limits the industrial application of these motors. Although several methods for smooth-toque operation (STO) have been proposed, STO works well only within a certain torque and speed range because of the constraints of the supply voltage and peak current. Based on previous work that sought to expand the STO range, a scheme is developed in this study to determine the maximum smooth torque range at each speed. The relationship between the maximum smooth torque and speed is defined as the smooth torque speed characteristics (STSC), a concept similar to torque speed characteristics (TSC). STSC can be utilized to evaluate torque utilization by comparing it with TSC. Thus, the concept benefits the special design of SRMs, especially for the generation of smooth torque. Furthermore, the torque sharing function (TSF) derived from the proposed method can be applied to STO, which produces a higher smooth torque over a wider speed range in contrast to four typical TSFs. TSimulation and experimental results verify the proposed method.

MIMO Spatial Multiplexing에서 안테나별 송신신호의 PAPR 감소 기법 (PAPR Reduction in MIMO Spatial Multiplexing for transmission antennas)

  • 배재휘;이광순;안충현
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2011년도 하계학술대회
    • /
    • pp.466-469
    • /
    • 2011
  • 최근 무선전송에서 SISO(single input singe output) 시스템의 전송률이 샤논 한계(Shannon limit)에 근접함에 따라, 이것을 극복하여 더 높은 데이터 전송률을 얻기 위해 MIMO(multiple input multiple output) 시스템에 대한 연구가 활발하게 이루어지고 있다. 현재 진행 중인 DVB-NGH 시스템 표준화에도 전송률 개선을 위해 MIMO SM(Spatial Multiplexing) 기술에 대해 고려하고 있으며, 방송 시스템 내 송수신 안테나들 간 상관(correlation)이 발생하는 경우에 성능 개선을 위해 Precoding과 MIMO SM을 결합한 $2{\times}2$ 구조의 MIMO SM 방법이 제안되었다. 이 방법은 두 개의 송신안테나에 모두 16QAM 신호가 전송되는 경우와 두 송신안테나에 각각 16QAM, QPSK 신호가 전송되는 경우를 포함하고 있다. 이때 고출력 증폭기(high power amplifier) 전단에서 두 송신 안테나에 서로 다른 변조가 적용되는 경우에 PAPR(peak-to-average power ratio)이 달라서 고출력 증폭기 출력단의 송신전력 차이로 인해 각 신호의 방송권역(coverage)이 같지 않은 문제가 발생한다. 본 논문은 이러한 문제를 극복하기 위해 $2{\times}2$ MIMO SM 방식에서 송신 안테나별로 신호의 변조방식이 서로 다른 경우에 송신신호의 PAPR을 같게 하여 증폭기 출력단에서 각 송신신호의 전력이 동일하게 할 수 있는 방법을 제안한다. 제안한 방법은 수신기의 복잡도를 증가시키지 않으면서 두 송신 신호의 방송권역을 동일하게 한다.

  • PDF

Design and Performance Analysis of Pre-Distorter Including HPA Memory Effect

  • An, Dong-Geon;Lee, Il-Jin;Ryu, Heung-Gyoon
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.71-77
    • /
    • 2009
  • OFDM(Orthogonal Frequency Division Multiplexing) signals sutler serious nonlinear distortion in the nonlinear HPA(High Power Amplifier) because of high PAPR(Peak Average Power Ratio). Nonlinear distortion can be improved by a pre-distorter, but this pre-distorter is insufficient when the PAPR is very high in an OPFDM system. In this paper, a DFT(Discrete Fourier Transform) transform technique is introduced for PAPR reduction. It is especially important to consider the memory effect of HPA for more precise predistortion. Therefore, in this paper, we consider two models, the TWTA(Traveling-Wave Tube Amplifier) model of Saleh without a memory effect and the HPA memory polynomial model that has a memory effect. We design a pre-distorter and an adaptive pre-distorter that uses the NLMS(Normalized Least Mean Square) algorithm for the compensation of this nonlinear distortion. Without the consideration of a memory effect, the system performance would be degraded, even if the pre-distorter is used for the compensation of the nonlinear distortion. From the simulation results, we can confirm that the proposed system shows an improvement in performance.

Antioxidant Properties of Different Polysaccharides Extracted with Water and Sodium Hydroxide from Rice Bran

  • Zha, Xue-Qiang;Luo, Jian-Ping;Zhang, Lei;Hao, Jie
    • Food Science and Biotechnology
    • /
    • 제18권2호
    • /
    • pp.449-455
    • /
    • 2009
  • The antioxidant properties of water extracted polysaccharides (PW), 1%(w/v) NaOH extracted polysaccharides (PN1), and 5%(w/v) NaOH extracted polysaccharides (PN5) were assessed in this paper. PW showed good capability of scavenging $H_2O_2$, anti-lipid peroxidation, reduction power, and scavenging 1,1-diphenyl-2-picrylhydrazyl (DPPH). The maximum values were all observed at the dose of 1 mg/mL sample. As far as the antioxidant activities of PN1 were concerned, the capability of scavenging superoxide radical, chelating metal, and total antioxidation showed higher than those of PN5. When polysaccharide concentration was 1 mg/mL, the 3 index described above were attached 71.8%, 51.6%, and $446.3{\mu}M$ Trolox equivalent, respectively. With respect to PN5, higher capabilities of scavenging hydroxyl free radicals were obtained while the peak of 84.8% was observed at the concentration of 1.0 mg/mL. Moreover, the concentration-dependent influences were characterized in all cases.

영상태 벡터를 사용하지 않는 매트릭스 컨버터의 공통모드 전압 저감에 관한 연구 (The Reduction of Common-Mode Voltage in Matrix Converter without Using Zero Space Vector)

  • 윈민항;이홍희;정의헌;전태원;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.638-642
    • /
    • 2005
  • This paper proposes a modified space-vector pulse width modulation (PWM) strategy which can restrict the common-mode voltage for three-phase to three-phase matrix converter and still keep sinusoidal input and output waveforms and unity power factor at the input side. The proposed control method has been developed based on contributing the appropriate space vectors instead of using zero space vectors. The advantages of this proposed method is to reduce the peak value of common-mode voltage to 42% beside the lower high harmonic components as compared to the conventional SVM method. Hence, the new table is also presented with the new space vector rearrangement. Furthermore, the voltage transfer ratio is unaffected by the proposed method. A simulation of the overall system has been carried out to validate the advantages of the proposed method.

  • PDF

신재생에너지 연계형 에너지관리장치의 운영 사례 연구 (A Case Study on Operation of Energy Management System Connected with Renewable Energy)

  • 조재영;나인호
    • 스마트미디어저널
    • /
    • 제7권2호
    • /
    • pp.71-77
    • /
    • 2018
  • 본 논문에서는 신재생에너지 발전과 연계한 에너지저장시스템(ESS)의 최적 운영을 위한 에너지관리시스템(EMS)의 구성요소 설계 시 고려할 기능, 운영 효과 분석과 전력요금 절감 방안을 제안한다. 이를 위해 태양광 발전 시스템에 리튬이온전지 기반의 배터리 시스템과 에너지관리시스템 연계 및 구축방안을 제시하고, 1년 동안 운영 데이터에 대한 분석한 결과를 기술한다. 또한 시스템 운영 효과를 높이기 위한 방안으로 EMS를 이용하여 최대수요 발생시간대의 피크전력을 경부하 시간대 충전전력으로 대체하여 ESS 전용 요금제에 따른 요금편익과 부하 평준화에 기여하는 효과를 제안한다.

Key parameters of toroidal HTS coil for a superconducting magnetic energy storage system

  • Miyeon, Yoon;Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Jung Tae, Lee;Seungyong, Hahn;Woo-Seok, Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.50-54
    • /
    • 2022
  • High temperature superconducting (HTS) magnets for large-capacity energy storage system need to be composed of toroid magnets with high energy density, low leakage magnetic fields, and easy installation. To realize such a large capacity of a toroid HTS magnet, an HTS cable with large current capacity would be preferred because of the limited DC link voltage and instantaneous high power required for compensation of the disturbance in the power grid. In this paper, the optimal operating strategies of the SMES for peak load reduction of the microgrid system were calculated according to the load variation characteristics, and the effect of compensation of the frequency change in microgrid with a SMES were also simulated. Based on the result of the simulation, key design parameters of SMES coil were presented for two cases to define the specification of the HTS cable with large current capacities for winding of HTS toroid coils, which will be need for development of the HTS cable as a future work.

급속충전방식 무가선 전동차 시스템을 이용한 전기요금 절감 방안 연구 (Study of Electric Charge Saving Plan Using High-speed Charging Wireless Railway System)

  • 고효상;조인호;류준형;김길동
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.31-42
    • /
    • 2017
  • 철도 시스템의 전력 소비를 줄이기 위한 많은 연구가 진행되고 있다. 그 중에서 급속충전방식 무가선 전동차 시스템은 철도 분야에서 매우 효율적인 에너지 절감 기술로 주목 받고 있다. 본 논문에서는 ESS를 이용한 급속충전 무가선 전동차 시스템을 소개하고 현재의 도시철도 전기요금 산정방식에 대하여 분석하였다. 이러한 분석을 바탕으로 급속 충전 무가선 전동차 시스템 적용 가능한 두 가지 전기요금 저감 방안(기본요금을 저감하는 방식(Case 1)과 전력량요금을 저감시키는 방식(Case 2))을 제안하였다. 제한하는 방식의 타당성 확인을 위해 현재 운영 중인 전동차 시스템(도시철도 2호선)의 전기요금과 비교하여 비용 경제성을 평가하였다.

가정용연료전지 전기적 안전성 평가 기법 개발 (Development of Electrical Safety Evaluation Method about PEMFC 1kW)

  • 한운기;박찬엄;정진수;고원식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.99-99
    • /
    • 2011
  • Fuel cell systems are a completely different form of electricity source that has been used so far and is an aggregation of multiple technologies with multidisciplinary features that can be operated safely only when gas and electrical safety are being considered. Since fuel cells generate through electrochemical reactions there are difficulties in ensuring electricity safety, power quality assessment, effective control and reliability standards for system faults using conventional inspection techniques and even though they are necessary as a primary means for reduction of CO2 owing to the Climate Convention, electrical safety assessment and measures are required for the prevention of faults in residential facilities. Although small-scaled distributed power supplies can be utilized as important means of peak control and energy management measures, research is required for observing the effects on the system and the development of inspection technology to ensure stable operation, and the electrical safety of residential fuel cell systems need to be assessed and the problems derived for establishing electrical safety standards. From the year 2002, Japan has established laws on technical safety standards and development and rules on the product specifications and standards for the industrialization of hydrogen fuel cells. Also, a lot of effort have been made for the commercialization of fuel cells by building one-stop certification services. Internationally, the IEC TC 105 has established international standards based on fuel cells. In order to protect the national interest, the country should be able to respond accordingly meet global standards. In fact, in Korea, to comply with the international trend, Korea Energy Management Corporation is establishing a certified agenda for fuel cells and Korean Agency for Technology and Standards is enacting technical standards for fuel cells. The current terms of fuel cells are that research has been focused more on the quality and performance of manufactured products rather than stable power operation and maintenance over time. In this paper, by considering the household fuel cell as a power device, the safety standards of the fuel cell system for a reliable operation with the existing power system is being proposed.

  • PDF