• Title/Summary/Keyword: Peak power

Search Result 2,618, Processing Time 0.035 seconds

Analysis of Electric Power Peak-Cut Effect by Gas Cooling (가스냉방 전력대체효과 분석)

  • Jeong, Si-Young;Kim, Dae-Hwan;Park, Ki-Woong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.208-211
    • /
    • 2009
  • To reduce the peak demand the promotion of gas cooling(absorption chillers and GHPs) is required. In this study the effect of electric power peak-cut has been analyzed using two methods. One is based on monthly LNG consumption data and the other is using the gas cooling capacity installed. Both methods agreed well with each other within the uncertainty of 20%. It was found that the gas cooling had the peak cut effect of 1,500-2,000 MW for recent 5 years (2003 - 2007). The ratio of gas cooling to the whole cooling demand was 12-15%, which is needed to be increased.

  • PDF

A Comparison of Muscle Strength by Russian Current and Low Frequency Current Stimulation in Normal Adult (정상성인에서 러시안 전류와 저주파 전류 자극에 의한 근력 증가의 비교)

  • Kim, Jong-Youl
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.353-360
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the effect of muscle strength by stimulation of russian current and low frequency. Methods : The subjects were thirty young healthy volunteers who were divided into two groups including russian current group(n=15) and low frequency group(n=15). The intervention was applied totally 12 times (1 time, 10 minute) for 4weeks in each group. The peak torque and average power were measured and analysed using Biodex system 4 before the treatment, after 2 weeks, 4 weeks. Results : As a result, russians currents and low frequency stimulation increased significantly average power and peak torque with the lapse of time. However, there were not significant differences of the average power and peak torque between the groups in all periods. Conclusion : In conclusion, russians currents and low frequency stimulation had no differences in the increase of muscle strength.

A Study on the Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Atomic Layer-Deposited Thin-Film Electrolyte (수소연료를 이용하는 원자층증착 박막전해질 세라믹연료전지의 초기성능 저하에 관한 연구)

  • JI, SANGHOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.410-416
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~17% for 40 minutes, which rapidly decreased in the early stage of the performance evaluation but gradually decreased. The open circuit voltage ratio decreased with respect time; however, its time behavior was remarkably different with the reduction behavior of the peak power density ratio. The activation resistance ratio increased as ~15% for 40 minutes, which was almost similar with the time behavior of the peak power density ratio.

Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Plasma-Enhanced Atomic Layer-Deposited Ultra-Thin Electrolyte (플라즈마 원자층증착 초박막전해질 수소 세라믹연료전지의 초기성능 저하)

  • JI, SANGHOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.340-346
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte fabricated by plasma-enhanced atomic layer deposition method was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~52% for 30 min, which continually decreased as time increased but degradation rate gradually decreased. The open circuit voltage ratio decreased with respect time; however, its behavior was evidently different from the reduction behavior of the peak power density. The activation resistance ratio increased as ~127% for 30 min, which was almost similar with the reduction behavior of the peak power density ratio.

Power Optimization Method Using Peak Current Modeling for NAND Flash-based Storage Devices (낸드 플래시 기반 저장장치의 피크 전류 모델링을 이용한 전력 최적화 기법 연구)

  • Won, Samkyu;Chung, Eui-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • NAND flash based storage devices adopts multi-channel and multi-way architecture to improve performance using parallel operation of multiple NAND devices. However, multiple NAND devices consume higher current and peak power overlap problem influences on the system stability and data reliability. In this paper, current waveform is measured for erase, program and read operations, peak current and model is defined by profiling method, and estimated probability of peak current overlap among NAND devices. Also, system level TLM simulator is developed to analyze peak overlap phenomenon depending on various simulation scenario. In order to remove peak overlapping, token-ring based simple power management method is applied in the simulation experiments. The optimal peak overlap ratio is proposed to minimize performance degradation based on relationship between peak current overlapping and system performance.

Fuzzy LP Based Power Network Peak Shaving Algorithm (퍼지 LP 기반 전력망 Peak Shaving 알고리즘)

  • Ohn, Sungmin;Kim, Jung-Su;Song, Hwachang;Chang, Byunghoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.754-760
    • /
    • 2012
  • This paper describes peak shaving algorithms as long-term cycle scheduling in the power management system (PMS) for MW-scale battery energy storage systems (BESS). The purpose of PMS is basically to manage the input and output power from battery modules placed in the systems. Assuming that an one-day ahead load curve is provided, off-line peak shaving algorithms can be employed, but applying the results of the off-line algorithm may result in the difference in the real-time performance because there is uncertainty in the provided load curve. This paper adopts fuzzy based LP (linear programming) algorithms for describing the peak shaving algorithm in PMS and discusses a solution technique and real-time operation strategies using the solution.

Impact Analysis of the Power Generation Capacities of New and Renewable Energy on Peak Electricity Supply (신·재생에너지 전원이 피크타임 전력 공급에 미치는 영향)

  • Kim, Suduk;Kim, Yungsan
    • Environmental and Resource Economics Review
    • /
    • v.15 no.2
    • /
    • pp.269-296
    • /
    • 2006
  • With the concern of the potential problems which can be observed in terms of the power supply of renewable energies, we need to analyze the impact of additional power generation capacities of renewable energy sources on peak load. Each renewable energy sources are dependent upon wind speed, solar radiation, head differences caused by lunar calendar. Considering that these exogenous renewable energy sources follow their own stochastic distributions, we analyze the probability distribution of the impact of each renewable energy power supply on peak load. As a conclusion, we note that traditional tools used for the analysis of power supply such as capacity factors are no longer appropriate for the analysis of renewable energy sources in that perspective.

  • PDF

Output Power Back-Off (OPBO) Based Asymmetric Doherty Power Amplifier (출력 전력 백-오프 기반 비대칭 도허티 전력 증폭기)

  • Chun, Sang-Hyun;Jang, Dong-Hee;Kim, Ji-Yeon;Kim, Jong-Heon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.2
    • /
    • pp.51-59
    • /
    • 2010
  • In this paper, we propose an inverted type asymmetric Doherty amplifier with optimized efficiency characteristic in wanted output power back-off (OPBO) range according to peak to average power ratio of input signal In order to obtain optimized efficiency of the asymmetric Doherty amplifier in wanted OPBO, peak power ratio between main amplifier and peaking amplifier was determined and then impedance of 90 degrees impedance transformer was obtained by peak power ratio. The offset line length and peak dividing ratio of the asymmetric Doherty amplifier were also calculated. From the measurement results, the proposed amplifier has achieved 40 % drain efficiency and -35 dBc adjacent channel leakage ratio at the average output power of 48.7 dBm for CDMA 2000 1x 3-FA test signal.

Measurement of Peak-to-Average Power Ratio for HRIT

  • Park Durk-Jong;Yang Hyung-Mo;Ahn Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.498-500
    • /
    • 2004
  • QPSK (Quaternary Phase Shift Keying) will be adopted as the modulation of HRIT (High Rate Information Transmission) which is transmitted to COMS (Communication, Ocean and Meteorological Satellite) through HPA (High Power Amplifier) in ground segment. Due to the nonlinearity of HPA, IMD (Inter-Modulation Distortion) of multi-carrier signals and PAPR (Peak-to-Average Power Ratio) of modulated HRIT must be considered to estimate the output power of HPA. In this paper, we measured the PAPR to various the roll-off factor of RRC (Root Raised Cosine filter) which is filtering the modulated HRIT signal for reducing ISI (Inter-Symbol Interference) and bandwidth. It was found that the minimum PAPR is 2.78dB at 0.5 of roll-off factor for scrambled data. It's 2.78dB of P APR will be in output power selecting in COMS earth station.

  • PDF

Cooling System for Power Transformer Using Weighting Function (하중함수를 이용한 전력용 변압기 냉각 시스템)

  • Cho, Do-Hyeoun
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.40-45
    • /
    • 2012
  • In this paper, cooling system of power transformers is proposed for temperature optimized control. We predict the peak temperature of power transformer coils using load factors and construct a cooling system using weighting function. For the optimized temperature control for power transformer, a correlation function based on the load factor of a load current and the each temperatures for winding coils, for air and for oil is presented to predict the winding-coil peak temperature. Also, the results controlled by applying the power transformer is presented.