• Title/Summary/Keyword: Peak operation

Search Result 806, Processing Time 0.029 seconds

Characteristics on the response of the stern trawler according to the state of its operation (선미트롤어선의 운항 형태에 따른 거동 특성)

  • PARK, Chi-Wan;KIM, Jong-Wha;KIM, Hyong-Seok;KANG, Il-Kwon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.4
    • /
    • pp.339-346
    • /
    • 2016
  • The aim of this research was to the experimental data using statistical and spectral analyzing method to get the motion reponses of a stern trawler in operation states such as drifting, sailing and trawling according to the wave height. In drifting, the significant and the maximum valuer of roll in beam sea increased according to the wave height, but those of pitch decreased. The response and the period of peak of roll in beam sea were increased, but those of pitch decreased. In navigation, the significant and maximum values of roll increased remarkably according to the wave height, but those of pitch changed a little. The response of roll was highest in quartering sea, beam sea and then following sea, but those of pitch was highest in bow sea, head sea and then beam sea in the order of all wave heights. The period of peak of roll due to the wave height and the wave direction changed from 3.8 to 9.9 seconds, and those of pitch changed from 3.3 to 10.4 seconds. In trawling, the significant and maximum values of roll increased a little according to the wave height, but those of pitch increased significantly. The response of roll was highest in beam sea, bow sea and then quartering sea, but those of pitch was highest in head sea, following sea, and then beam sea in the order. The period of peak of roll due to the wave height and the direction changed from 6.6 to 10.9 seconds, and those of pitch changed from 6.7 to 11.2 seconds.

KTX Impact on Train Operation Pattern (An Empirical Analysis) (서울-천안 구간의 열차운행패턴 분석과 시사점)

  • Kim Kyoung-Tae;Lee Jin-Sun
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.1047-1053
    • /
    • 2005
  • This study explored pattern of train operation between Seoul Cheonan after the introduction of KTX in 2004. Both number of trains and seat capacity per day have increased but maximum number of trains per specific hour hasn't changed much. Demand for train shows that it concentrated in a specific time, so number of trains during the peak hour should be increased. But, it is difficult due to line capacity, so increasing seat capacity per train might be an option. An increase in seat capacity should be considered the characteristics of each train lines.

  • PDF

A Study on the EDT Characteristics of TM Work Roll and Variation of Strip Surface Roughness

  • Kim, Soon-Kyung;Moon-Kyung, Kim
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 2001
  • This paper investigates the correlation between strip surface roughness and the surface of the work roll. As the actual temper mill(TM) is used, this data will be adopted to another actual temper mill for the application and operation of this experiment. Conclusions are as follows: Electro-discharge texturing(EDT) roll has homogeneous roughness distribution and shape, and also a sinuous peak surface and the life is 2 times longer than that of shot blast texturing(SBT) method. And the higher surface roughness of work roll, the more time is necessary at the EDT method. In the SBT method without the correlation of roughness, but impeller rotation speed with an uncontrollable peak count. The roughness of SBT roll is irregularity compared to that of EDT roll because the work roll roughness is transferred to the strip which was temper rolled, and produces a more desirable image and greater clarity to the color painted steel sheet.

  • PDF

An E-capless AC-DC CRM Flyback LED Driver with Variable On-time Control

  • Yao, Kai;Bi, Xiaopeng;Yang, Siwen
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.315-322
    • /
    • 2017
  • LED is a promising new generation of green lighting with the advantages of high efficiency, good optical performance, long lifetime and environmental friendliness. A pulsating current can be used to drive LEDs. However, current with a high peak-to-average ratio is unfavorable for LEDs. A novel control scheme for the ac-dc critical conduction mode (CRM) flyback LED driver is proposed in this paper. By using the input voltage, output voltage and average output current to control the turn-on time of the switch, the peak-to-average ratio of the output current can be reduced. The operation principle is analyzed and an implementation circuit is put forward. Experimental results show the effectiveness of the proposed scheme.

Daily peak load forecasting considering the load trend and temperature (수요경향과 온도를 고려한 1일 최대전력 수요예측)

  • 최낙훈;손광명;이태기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.35-42
    • /
    • 2001
  • Since daily peak load forecasted data are essential to economic operation and power monitor, the technique of accurate forecasting is needled. The chief advantage of forecasting technique using neural network and fuzzy theory is high accuracy and operative implicity but the loaming time is long, and it makes large forecasting error when the load changes rapidly. This paper has resented a new forecasting technique to improve those faults and the forecasting technique prove to be valid by forcasted results.

  • PDF

A Study on the Development of the Large Building Air-conditioning System with the Regenerative Ice-energy and its Computer Aided Design (빙축열을 이용한 대형빌딩 공기조화시스템 개발과 설계전산화에 관한 연구)

  • 권형정;김원영;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.38-46
    • /
    • 1991
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air-conditioning systems are being operated during daytime in summer season. Therefore, it is necessary to construct an additional electric power plant and to develop the new air-conditioning system for relieving the peak load. This paper analysed the performance characteristics of this experimental regenerative ice energy system by means of a bundle of the heat-pipes. And the result of this analysis was applied to the simulation of an air-conditioning system model. Also, an operation program of moisture air was made according to air load and in order to computerize the air-conditioning system a CAD program was developed by the properties of moisture air.

  • PDF

Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System (교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구)

  • Jeon, Yong-Joo;Kang, Byoung-Wook;Chai, Hui-Seok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

Analysis on Current Limiting Characteristics According to the Influence of the Magnetic Flux for SFCL with Two Magnetic Paths

  • Ko, Seok-Cheol;Han, Tae-Hee;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1909-1913
    • /
    • 2014
  • In this study, a superconducting fault current limiter (SFCL) having two magnetic paths was proposed, and its current limiting characteristics were analyzed. For the SFCL to effectively perform the current limiting operation, it must be designed considering the magnetic saturation of the E-I core. Further, the influence of the magnetic flux on its peak current limiting characteristics was investigated. In addition, the magnetic flux curves of the SFCL obtained from the fault current limiting experiments were analyzed, and the subtractive polarity winding case was observed to not only further reduce the saturation potential of the core but also perform the peak current limiting functions well when compared with the additive polarity winding case.

Peak Power Control for Improvement of Stability in Multi-core System (멀티코어 시스템의 안정성 향상을 위한 피크파워 제어 알고리즘)

  • Park, Sung-Hwan;Kim, Jae-Hwan;Ahn, Byung-Gyu;Jung, Il-Jong;Lee, Seok-Hee;Chong, Jong-Wha
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.747-748
    • /
    • 2008
  • In this paper, we propose a new algorithm for task scheduling consisting of subtask partitioning and subtask priority scheduling steps in order to keep the peak power under the system specification. The subtask partitioning stepis performed to minimize the idle operation time for processors by dividing a task into multiple subtasks using the least square method developed with power consumption pattern of tasks. In the subtask priority scheduling step, a priority is assigned to a subtask based on the power requirement and the power variation of subtask so that the peak power violation can be minimized and the task can be completed within the execution time deadline.

  • PDF

A Electronic Starter for Fluorescent Lamps for use as Neon Signs (네온사인 기능을 수행하는 형광램프용 전자식 스타터)

  • 송상빈;곽재영;여인선;임건호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.228-233
    • /
    • 1999
  • In this paper we develop an electronic starter circuit that is suitable for Neon sign operation of switch-start fluorescent lamps. The developed starter enable single pulse ignition of fluorescent lamp at the peak point of preheating current, irrespective of the position of the Tum-On signal. This is possible due to the sequential operation of two transistors different in their operation characteristics and a diode operation characteristic. The switching endurance test using this starter has been carried for more than 3000 hours for a single switch-start on a severe blinking condition of preheating of 0.1s and of successive lighting interval of 0.1s.

  • PDF