• 제목/요약/키워드: Peak load management

검색결과 144건 처리시간 0.033초

Energy Efficient Cell Management by Flow Scheduling in Ultra Dense Networks

  • Sun, Guolin;Addo, Prince Clement;Wang, Guohui;Liu, Guisong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4108-4122
    • /
    • 2016
  • To address challenges of an unprecedented growth in mobile data traffic, the ultra-dense network deployment is a cost efficient solution to off-load the traffic over other small cells. However, the real traffic is often much lower than the peak-hour traffic and certain small cells are superfluous, which will not only introduce extra energy consumption, but also impose extra interference onto the radio environment. In this paper, an elastic energy efficient cell management scheme is proposed based on flow scheduling among multi-layer ultra-dense cells by a SDN controller. A significant power saving was achieved by a cell-level energy manager. The scheme is elastic for energy saving, adaptive to the dynamic traffic distribution in the office or campus environment. In the end, the performance is evaluated and demonstrated. The results show substantial improvements over the conventional method in terms of the number of active BSs, the handover times, and the switches of BSs.

동계피크시 계약종별 난방부하분석 및 수요관리 대응방안 연구 (A Study On heating load analysis and demand side management on winter peak period)

  • 강동필;윤용범;이경진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.588-589
    • /
    • 2011
  • `10. 1. 13일 한파지속에 따른 16년 만에 동계피크가 발생 하였으며, '11. 1. 17일 73,137MW로 2년 년속 동계피크 경신으로 우리나라도 이젠 동계피크 발생국가에 해당된다고 볼 수 있다. 이는 경기회복에 따른 산업용전력의 증가가 동계피크 발생을 견인하였지만 타 에너지원에 비해 전기요금이 저렴하기 때문에 난방연료원이 가스나 가름에서 전기로 지속적으로 전환된 것이 가장 큰 원인이라고 보여 진다. 효과적인 전력수요관리를 위해서는 계약종별별로 부하량과 난방부하량을 측정해서 분석하는 것이 무엇보다 중요하다 하겠다. 그렇지만 실시간으로 계약종별로 부하량 자료를 얻을 수 있는 것은 현재 고압고객의 AMR계량시스템자료가 있으나 이는 고압전체의 85% 대 수준의 자료를 읽어올 뿐 전제 부하를 대변할 수 없으므로 발전단 부하를 계약종별로 적절하게 안분하는 것이 필요하다고 볼 수 있다. 8760시간대별 부하분석을 위해서는 발전단 부하와 배전단부하를 근간으로 고압고객의 원격자동검침(AMR) 자료를 활용하여 최대피크기여도를 분석하여 부하분석을 수행하였다.

  • PDF

Research on the Performance of Protocols and the Evaluation Metric for VIDEO Transmissions in an Ad Hoc Network

  • Chen, Ruey-Shin;Chao, Louis R.;Chen, Ching-Piao;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • 제10권1호
    • /
    • pp.115-126
    • /
    • 2009
  • Video transmission effectiveness in the Ad Hoc network is becoming important recently, if different routing protocols are applied. Some researchers conclude that the reactive protocols are better for file transfer protocol (FTP) and constant bit rate (CBR) or hypertext transfer protocol (HTTP) transmission in an Ad Hoc wireless network but the performance report of video transmission is not much. This study adopts Qualnet (Network Simulator) as a simulation tool for environmental designing and performance testing, and employs an experimental design with eight groups. Our experiment shows that: (1) The performance of AODV (reactive) protocol is better than DSDV, ZRP and DSR when the transmission load has only one video stream; (2) Proactive (DSDV) and Hybrid protocols (ZRP) are better for a smaller Ad Hoc network when it transmits a video stream with some applications (VoIP, FTP and CBR). We conclude that packet loss rate is sensitive to the quality of video transmission and it has negative relationship with Peak Signal-to-Noise Ratio (PSNR) value. In addition, our experiment also shows that PSNR is a simple Metric for the performance evaluation of video transmission.

고도화 도시지역에 적용된 LID 기법의 비점오염물질 관리 및 이동 (Transport and management of diffuse pollutants using low impact development technologies applied to highly urbanized land uses)

  • ;최혜선;김이형
    • 한국습지학회지
    • /
    • 제21권2호
    • /
    • pp.173-180
    • /
    • 2019
  • 본 연구는 도로, 주차장 및 지붕에서 발생된 TSS와 중금속의 거동을 분석하기 위해 수행되었다. 강우시 도로, 주차장, 지붕에서 발생되는 중금속은 입자상 물질(TSS)에 부착되어 이동된다. 이는 TSS 부하량과 Cr, Fe, Cu 및 Pb의 입자상 중금속 및 용존성 중금속의 부하량의 상관관계로 판단 가능하다(r =0.52~0.73, p <0.01). 일반적으로 도로 및 주차장에서 발생된 TSS 및 중금속은 지붕에 비해 더 높은 것으로 분석되었는데, 이는 차량에 의해 중금속이 많이 발생하며, 집수면적 또한 도로 및 주차장이 넓기 때문으로 보여진다. 첨두유출발생시까지 TSS 부하량의 65~75%가 유출되는 것으로 나타났으며, 이는 인근 수계로 유출되는 TSS를 제거하기 위해서는 첨두유출을 제어하는 것이 가장 효과적인 것을 의미한다. 또한 비용경제적인 LID 시설의 규모를 산정하기 위해 시설의 적정 크기(시설의 표면적/배수구역 면적)에 따른 TSS와 중금속 제거율을 평가하였다. 본 연구는 LID 시설의 설계시 참고 가능한 기초데이타로 중요한 의미가 있는 것으로 사료된다.

수용가용 전력저장시스템의 경제성분석에 관한 연구 (A Study on the Economic Analysis of the Energy Storage System in Customer)

  • 김정호;장준오
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.47-54
    • /
    • 2014
  • Recently, BESS is considered as one of essential countermeasure for demand side management. However, an economic evaluation is critical issue for the introduction of power system because the cost of BESS is very high in present stage. Therefor, this paper presents economic evaluation method for customer use case by considering peak shaving function based on the real time price. From the case study on the model power system and educational customer, it is confirmed that the proposed method is a practical tool for the economic analysis of BESS. and analytical approach for the reliability assessment in radially operated distribution systems. The approach can estimate the expected reliability performance of distribution systems by a direct assessment of the configuration of the systems using the reliability indexes such as NDP (Non-Delivery Power) and NDE (Non-Delivery Energy). The indexes can only consider the number and configuration of the load, but can not consider the characteristics of the load which is the one of the most important factor in the investment cost for the distribution systems. Therefore, this paper presents the new performance indexes for the investment of the distribution facilities considering both the expected interruption cost for the load section and the operation characteristics of Energy Storage System. The results from a case study show that the proposed methods can be a practical tool for the reliability management in distribution systems including Energy Storage System.

고속도로 노면 강우유출 오염부하 원단위 산정 (Analysis of Unit Pollution Load on Highway runoff)

  • 강희만;이두진;배우근
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.55-68
    • /
    • 2012
  • Impervious surface increase due to urbanization, one of the leading causes of pavement increased the runoff coefficient, peak flow, and reducing the infiltration flow and thereby causing flooding and river erosion is occurring in aquatic ecosystems are known to impair. This study aimed to classify use type of detailed land into the road, reststop, tollgates and etc. focused on major domestic highways, to understand the characteristics of rainfall runoff pollutants and to calculate applicable unit pollution load. Because of high runoff coefficient and short travel time to drainage. first flush occurred clearly. Average EMCs of runoff in the highway was investigated as TSS 108.47 mg / L, COD 28.16 mg / L, BOD 13.61 mg / L, TN 6.38 mg / L, TP 0.03 mg / L, Cu 118.17 ${\mu}g$ / L, Pb 345.3 ${\mu}g$ / L, Zn 349.47 ${\mu}g$ / L. Unit pollution loads calculated by detailed land use area of highways based on average annual rainfall, EMCs, applicable basin areas and etc. were 46.6 kg/km2/day of BOD, 1.4 kg/km2/day of TP, 8.81 kg / km2/day of TN and these were BOD 50.8%, TP 66.7%, TN 64.4%in comparison of the unit pollution loads which applies fallow land standards of the TMDL(Total Maximum Daily Load). It was considered that discharged loads can be excessively calculated in case highway non-point management plans based on unit pollution load of the current land standard.

에너지절감을 위한 물 재이용 펌프시스템의 최적운전 제어 (Optimal Operation Control for Energy Saving in Water Reuse Pumping System)

  • 부창진;김호찬
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2414-2419
    • /
    • 2012
  • 본 논문에서는 물 재이용 펌프 시스템의 에너지 효율적 운전 방법을 제안한다. 1시간 단위의 시간대에서 최적운전제어를 위해 예측구간 스위칭방법과 선형계획법을 적용하고 에너지 비용은 경부하, 중부하, 그리고 최대부하를 포함한 TOU 요금과 피크요금을 통해 산정하도록 한다. 물 재이용 펌프시스템에서의 최적운전은 TOU 요금과 피크요금을 포함한 에너지 비용을 최대로 줄일 수 있도록 수행한다. 시뮬레이션을 통해 제안한 최적운전방법을 적용하면 많은 전력 에너지 비용의 절감과 전력계통의 안정성 향상을 확인할 수 있다.

스마트그리드를 통한 전기자동차의 전력망 영향 관리 효과 (Analysis of the Impact of Smart Grids on Managing EVs' Electrical Loads)

  • 박찬국;최도영;김현제
    • 디지털융복합연구
    • /
    • 제11권11호
    • /
    • pp.767-774
    • /
    • 2013
  • 전기자동차 보급이 확대됨과 동시에 충전이 특정 시간대에 몰리거나 전력수요가 높은 시간대에 늘어나면 전력수급 균형이 불안해질 수 있다. 따라서 전기자동차 충전으로 인한 전력수요가 증가함과 동시에, 전기자동차의 전력수요를 분산시키고, 전기자동차 배터리의 여분의 전기를 활용할 수 있는 스마트그리드 구축이 중요해진다. 아직 국내에서 스마트그리드가 전기자동차의 전력망 영향 관리에 어느 정도 영향을 미치는지에 대해서는 정량적 연구가 미흡한 실정이다. 본 연구는 스마트그리드를 통한 전기자동차의 전력망 영향 관리 효과를 정량적으로 분석하고 정책적 시사점을 제시하였다. 결과적으로 스마트그리드는 전기자동차의 전력망 영향을 효과적으로 관리할 수 있었다. 전력시장 구조와 규제 프레임워크는 스마트그리드 기술의 실증과 상용화 촉진을 뒷받침할 수 있어야 할 것이다.

머신러닝기반 확률론적 실시간 건물에너지 수요예측 및 BESS충방전 기법 (Stochastic Real-time Demand Prediction for Building and Charging and Discharging Technique of ESS Based on Machine-Learning)

  • 양승권;송택호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.157-163
    • /
    • 2019
  • 현재까지 피크완화 및 에너지 절감을 위해 한국전력공사 120여개 사옥에 K-BEMS (KEPCO Building Energy Management System)가 운영 중이다. 이 시스템은 PV, PCS, BESS, EMS 등으로 구성되어 있으며 건물에너지 수요예측을 기반으로 BESS, PV 등을 활용하여 에너지 관리를 도모하고 있다. 이 시스템은 단기 과거데이터에 신경망기법을 단순 적용하여 수요를 예측함에 따라 예측 정확도가 높지 않고 운영자 수작업을 통한 BESS 충방전으로 피크 저감이 곤란하며 운영 경제성 제고가 어려운 실정이다. 이러한 문제를 해결하기 위해 전력연구원에서는 2016년부터 3년간 연구과제를 수행하였는데 이를 통해 에러를 최소화하며 높은 신뢰도를 가지는 실시간 수요예측기법과 이에 기반한 BESS충방전 최적화 자동화 기술 개발, 성능을 검증하였기에 이를 본 논문에서 소개하고자 한다.

다양한 강우강도 및 패턴에 따른 WEPP 모형의 유출‧첨두유출‧토양유실량 평가 (Evaluation of Runoff‧Peak Rate Runoff and Sediment Yield under Various Rainfall Intensities and Patterns Using WEPP Watershed Model)

  • 최재완;류지철;김익재;임경재
    • 한국수자원학회논문집
    • /
    • 제45권8호
    • /
    • pp.795-804
    • /
    • 2012
  • 최근 강우강도 및 패턴이 변화함에 따라 전세계적으로 토양유실이 증가하고 있다. 그 결과, 수생태계 건전성이 악화되고, 농업작물이 피해를 입어 수확량이 감소된다. 그동안 유출 및 토양유실을 예측하거나 비점오염원을 감소시키는 연구가 많이 수행되어 왔다. USLE는 수년간 토양유실을 산정하는데 사용되어왔으나, 강우강도나 패턴변화를 적용하기에는 적절하지 못했다. 물리적 기반인 WEPP 모형은 다양한 강우강도 및 패턴변화를 적용하는데 적절하다. 본 연구에서는 WEPP 모형을 이용하여 Huff의 4분위, 다양한 강우간격, 설계강우에 따른 토양유실, 유출, 첨두유출을 산정하였다. 5분간격 강우 데이터와 60분 간격 강우 데이터를 비교한 결과 토양유실은 24%, 유출은19%, 첨두유출은 16%가 차이나는 것으로 나타났다. 유출 및 토양유실이 5분 간격 강우량에서 실측치와 가장 유사한 것으로 나타나 강우데이터의 간격이 짧을수록 더 정확하게 모의할 수 있는 것으로 나타났다. Huff의 4분위를 이용하여 토양유실량, 유출량, 첨두유출량을 산정한 결과 토양유실량, 유출량, 첨두유출량 모두 3분위에서 가장 높게 발생하는 것으로 나타났다. 강원도 홍천지역 빈도별 확률강우를 이용하여 토양유실량, 유출량, 첨두유출량의 변화를 모의하였다. 2년 빈도와 300년 빈도에서 강우량은 167% 증가하였다. 유사량과 유출량, 첨두유출량은 각각 906.2%, 249.4%, 183.9% 증가하여 유사량의 증가율이 가장 큰 것으로 나타났다. 본 연구의 결과에서 보이는 바와 같이 WEPP 모형을 이용하여 향후 기후변화에 따른 유출 및 토양유실의 예측이 가능할 것으로 판단된다.