• Title/Summary/Keyword: Peak interference

Search Result 192, Processing Time 0.028 seconds

Color Filter Based on a Sub-Wavelength Patterned Poly-Silicon Grating Fabricated using Laser Interference Lithography (광파장 이하의 주기를 갖는 다결정 실리콘 격자 기반의 컬러필터)

  • Yoon, Yeo-Taek;Lee, Hong-Shik;Lee, Sang-Shin;Kim, Sang-Hoon;Park, Joo-Do;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.20-24
    • /
    • 2008
  • A color filter was proposed and demonstrated by incorporating a subwavelength patterned 1-dimensional grating in poly silicon. It was produced by employing the laser interference lithography method, providing much wider effective area compared to the conventional e-beam lithography. A $SiO_2$ layer was introduced on top of the silicon grating layer as a mask for the etching of the silicon, facilitating the etching of the silicon layer. It was theoretically found that the selectivity of the filter was also improved thanks to the oxide layer. The parameters for the designed device include the grating pitch of 450 nm, the grating height of 100 nm and the oxide-layer height of 200 nm. As for the fabricated filter, the spectral pass band corresponded to the blue color centered at 470 nm and the peak transmission was about 40%. Within the effective area of $3{\times}3mm^2$, the variation in the relative transmission efficiency and in the center wavelength was less than 10% and 2 nm respectively. Finally, the influence of the angle of the incident beam upon the transfer characteristics of the device was investigated in terms of the rate of the relative transmission efficiency, which was found to be equivalent to 1.5%/degree.

3-channel Tiled-aperture Coherent-beam-combining System Based on Target-in-the-loop Monitoring and SPGD Algorithm (목표물 신호 모니터링 및 SPGD 알고리즘 기반 3 채널 타일형 결맞음 빔결합 시스템 연구)

  • Kim, Youngchan;Yun, Youngsun;Kim, Hansol;Chang, Hanbyul;Park, Jaedeok;Choe, Yunjin;Na, Jeongkyun;Yi, Joohan;Kang, Hyungu;Yeo, Minsu;Choi, Kyuhong;Noh, Young-Chul;Jeong, Yoonchan;Lee, Hyuk-Jae;Yu, Bong-Ahn;Yeom, Dong-Il;Jun, Changsu
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • We have studied a tiled-aperture coherent-beam-combining system based on constructive interference, as a way to overcome the power limitation of a single laser. A 1-watt-level, 3-channel coherent fiber laser and a 3-channel fiber array of triangular tiling with tip-tilt function were developed. A monitoring system, phase controller, and 3-channel phase modulator formed a closed-loop control system, and the SPGD algorithm was applied. Eventually, phase-locking with a rate of 5-67 kHz and peak-intensity efficiency comparable to the ideal case of 53.3% was successfully realized. We were able to develop the essential elements for a tiled-aperture coherent-beam-combining system that had the potential for highest output power without any beam-combining components, and a multichannel coherent-beam-combining system with higher output power and high speed is anticipated in the future.

Analysis of Volatile Organic Compounds in Sediments Using HS-GC/MS - Confirmation of Matrix Effects in External and Internal Standard Methods - (HS-GC/MS를 이용한 퇴적물 중 휘발성유기화합물 분석 - 외부 및 내부표준방법에서 매질영향 확인 -)

  • Shin, Myoung-Chul;Jung, Da-som;Noh, Hye-ran;Yu, Soon-ju;Seo, Yong-Chan;Lee, Bo-Mi
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.510-519
    • /
    • 2021
  • Volatile Organic Compounds (VOCs) in sediments, which can cause human health problems, have been monitored in Korea since 2014. Measured VOC concentrations can be affected by matrix type and the volatility of target substances. In this study, (1) VOCs volatility and the influence of matrix interference were confirmed, and (2) internal standards (IS) method was applied to improve analytical method. For these purposes, method detection limit (MDL), calibration linearity, precision and accuracy of VOCs were compared in various matrices using the IS. Some of VOCs in sediments showed different peak areas and reduced rates compared to water matrix. It was suggested that adsorption properties of sediments hindered the migration to vapor during heat pretreatment in headspace method. A calibration curve was created in clean sand. Recovery rates for the calibration curve method and IS applying method were 64.1~83.1% and 99.1~119.3%, respectively. Relative standard deviations ranged from 11.1% to 21.6% for the calibration curve method and those for IS ranged 4.7% to 13.7%. In case of real sediment, calibration curve and 1,2-Dichlorobenzene-d4 (ODCB) among IS were not suitable. The average recovery rate of Fluorobenzene (FBZ) increased by 56.4% and Relative Standard Deviation (RSD) by 4.7%. However, the recovery rate was increased in the samples with large values of igniting intensity. This study confirmed that influence of the matrix of VOCs in sediment, and addition of IS materials improved precision and accuracy. Although IS corrects volatilization and adsorption, it is recommended that more than two types of IS should be added rather than single.

Analysis of Aliphatic Carboxylic Acids Using Ion-Exchange Chromatography: Application to Groundwater Affected by Landfill Leachates (이온-교환 크로마토그래피를 활용한 유기산 분석: 매립지 침출수의 영향을 받은 지하수에 대한 적용)

  • Cheon, Su-Hyun;Koh, Dong-Chan;Ko, Kyung-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.2
    • /
    • pp.55-64
    • /
    • 2007
  • An analytical method using ion-exchange chromatography was developed for simultaneous quantification of low-molecularweight organic acids ($C_1-C_6$ aliphatic carboxylic acids) and inorganic anions, and then applied to the assessment of ground water contaminated by leachates from a municipal solid waste landfill. Peak interferences of halide ions to organic acids were removed by pretreatment of water samples with Ag-containing cartridges. This method allowed accurate detection of low-molecular weight organic acids (i.e., formate, acetate, propionate, pyruvate, succinate, and oxalateas) low as 0.5 mg/L with a linear dynamic range up to 20 mg/L within 11 min run time along with typical inorganic anions. High level of pyruvate and low level of formate and acetate were detected in groundwater and landfill leachates using the analytical method. Pyruvate concentration in groundwater showed a significant correlation with concentrations of $Cl^-$ and $HCO_3^-$, and pyruvate levels decreased along the downgradient from the landfill, indicating the sources of pyruvate are landfill leachate.

Transparent Monopole Antenna on the Front Glass of an Automobile for FM Band (자동차 전면 글래스용 FM 대역 투명 모노폴 안테나)

  • Lee, Juhyung;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.7
    • /
    • pp.477-483
    • /
    • 2018
  • A transparent antenna designed on the front glass of an automobile operating in the FM broadcast band(88~108 MHz) is proposed. A transparent antenna designed on the front glass of the automobile to avoid space limitation is typically positioned as a roof-mounted shark-fin antenna. An antenna designed on the front glass can reasonably solve the problems of low reception sensitivity and radiated interference from antennas for other service bands. The front glass has a unique closed-line structure, and this structure causes the surface current to flow to the front glass's surroundings; thus, the first resonance is caused before the broadcast band. Through the use of this closed-line structure, the surface current distribution is controlled, and an antenna for which the first resonance is operating in the frequency-modulated(FM) band can be designed. Moreover, the use of a micro-metal-mesh film that is a transparent electrode, suitable for designing a radio frequency device, enables the antenna to minimize visual perception through its transparency. The measured reflection coefficient($S_{11}$) of the antenna is less than -6 dB, and the average peak gain is -0.9 dB in the FM band. Experiments show that the transparent antenna on the front glass offers both the space and design freedom required to develop future automotive antennas.

A Canonical Piecewise-Linear Model-Based Digital Predistorter for Power Amplifier Linearization (전력 증폭기의 선형화를 위한 Canonical Piecewise-Linear 모델 기반의 디지털 사전왜곡기)

  • Seo, Man-Jung;Shim, Hee-Sung;Im, Sung-Bin;Hong, Seung-Mo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.9-17
    • /
    • 2010
  • Recently, there has been much interest in orthogonal frequency division multiplexing (OFDM) for next generation wireless wideband communication systems. OFDM is a special case of multicarrier transmission, where a single data stream is transmitted over a number of lower-rate subcarriers. One of the main reasons to use OFDM is to increase robustness against frequency-selective fading or narrowband interference. However, in the radio systems it is also important to distortion introduced by high power amplifiers (HPA's) such as solid state power amplifier (SSPA) considered in this paper. Since the signal amplitude of the OFDM system is Rayleigh-distributed, the performance of the OFDM system is significantly degraded by the nonlinearity of the HPA in the OFDM transmitter. In this paper, we propose a canonical piecewise-linear (PWL) model based digital predistorter to prevent signal distortion and spectral re-growth due to the high peak-to-average power ratio (PAPR) of OFDM signal and the nonlinearity of HPA's. Computer simulation on an OFDM system under additive white Gaussian noise (AWGN) channels with QPSK, 16-QAM and 64-QAM modulation schemes and modulator/demodulator implemented with 1024-point FFT/IFFT, demonstrate that the proposed predistorter achieves significant performance improvement by effectively compensating for the nonlinearity introduced by the SSPA.

Total Degradation Performance Evaluation of the Time- and Frequency-Domain Clipping in OFDM Systems (OFDM 시스템에서 시간 및 주파수 영역 클리핑의 Total Degradation 성능평가)

  • Han, Chang-Sik;Seo, Man-Jung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.17-22
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing) is a special case of multicarrier transmission, where a single data stream is transmitted over a number of lower-rate subcarrier. One of the main reasons to use OFDM is to increase robustness against frequency-selective fading or narrowband interference. Unfortunately, an OFDM signal consists of a number of independently modulated subcarriers, which can give a large PAPR (Peak-to-Average Power Ratio) when added up coherently. In this paper, we investigate the performance of a simple PAPR reduction scheme, which requires no change of a receiver structure or no additional information transmission. The approach we employed is clipping in the time and frequency domains. The time-domain clipping is carried out with a predetermined clipping level while the frequency-domain clipping is done within EVM (Error Vector Magnitude). This approach is suboptimal with lower computational complexity compared to the optimal method. This evaluation is carried out on the OFDM system with an nonlinear amplifier. The simulation results demonstrated that the PAPR reduction algorithm is one of ways to reduce the effects of the nonlinear distortion of an HPA (High Power Amplifier).

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

Anodic Stripping Voltammetric Determination of Iodide Ion with a Cinchonine-Copper(Ⅱ) Complex Modified Carbon Paste Electrode (Cinchonine-Copper(Ⅱ) 착물로 변성된 탄소반죽전극을 이용한 요오드 이온의 양극벗김전압전류법 정량)

  • Kwak, Myung Keun;Park, Deog Soo;Jeong, Euh Duck;Won, Mi Sook;Shim, Yoon Bo
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.5
    • /
    • pp.341-346
    • /
    • 1996
  • Electrochemical determination of iodide was carried out by stripping voltammetry with a $(Cin)Cu(NO_3)_2$ modified-carbon paste electrode. Iodide was coordinated onto the electrode surface containing $(Cin)Cu(NO_3)_2$ via ion exchange. The oxidation peak potential of incorporated iodide was +0.72 V. The optimum analytical conditions for the determination of iodide were investigated using linear sweep voltammetry. Optimum conditions for the electrochemical determination of iodide were as follows: i) A predeposition solution was 0.1 M $KNO_3.$ ii) The deposition time was 10 min. iii) The composition of the electrode was 40% (w/w). The detection limit for iodide was $1.0{\times}10^{-6}M$ and the relative standard deviation was ${\pm}5.5%\;in\;2.0{\times}10^{-5}M$(four repetitions). The interference effect of other anions were also investigated. $Cl^-,\;Br^-,\;C_2O_4^{2-},\;and\;ClO_4^-$ ions do not interfere for the determination of iodide. When $SCN^-$ was added to the deposition solution, the oxidation peak current of iodide ion was decreased roughly 32%.

  • PDF

High Resolution Spaceborne SAR Operation and Target Recognition Simulator Using STK (STK를 이용한 고해상도 위성 SAR 운용 및 표적물 추출 기법)

  • Lee, Bo-Yun;Lee, Seul-Ki;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.299-309
    • /
    • 2013
  • A comprehensive SAR(Synthetic Aperture Radar) simulation is considered to be a complicated task since a full knowledge of the signal propagation characteristics, antenna pattern, system internal errors and interference noises should be taken into account. In high resolution target application modes, the time varying nature of target RCS(Radar Cross Section) strongly affects the generated SAR images. In this paper, in-depth SAR simulations are performed and analyzed incorporating the STK tools and MATLAB software. STK provides realistic orbit parameters while its radar module helps to extract accurate radiometric parameters of ground targets. SAR raw data corresponding to a given target is generated and processed using MATLAB simulator. The performance is measured by PSLR(Peak Sidelobe Ratio) and ISLR(Integrated Sidelobe Ratio) for a point target, which can be used as reference parameters for accurate radiometric calibration. Finally, high resolution target simulations are performed by adopting time varying target RCS characteristics.