Investigation on Effective Peak Ground Accelerations Based on the Gyeongju Earthquake Records (경주지진 관측자료에 기반한 유효최대지반가속도 분석)

  • Shin, Dong Hyeon;Hong, Suk-Jae;Kim, Hyung-Joon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.425-434
    • /
    • 2016
  • This study investigates important parameters used to determine an effective peak ground acceleration (EPGA) based on the characteristics of response spectra of historical earthquakes occurred at Korean peninsula. EPGAs are very important since they are implemented in the Korean Building Code for the seismic design of new structures. Recently, the Gyeongju earthquakes with the largest magnitude in earthquakes measured at Korea took place and resulted in non-structural and structural damage, which their EPGAs should need to be evaluated. This paper first describes the basic concepts on EPGAs and the EPGAs of the Gyeongju earthquakes are then evaluated and compared according to epicentral distances, site classes and directions of seismic waves. The EPGAs are dependant on normalizing factors and ranges of period on response spectrum constructed with the Gyeongju earthquake records. Using the normalizing factors and the ranges of period determined based on the characteristics of domestic response spectra, this paper draw a conclusion that the EPGAs are estimated to be about 30 % of the measured peak ground accelerations (PGA).

Analysis of Factors Affecting Peak Loading Coefficient of Sewer Works in Korea (우리나라 하수도시설의 첨두부하율 영향요소 분석)

  • Hyun, In-Hwan;Lee, Young-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.877-884
    • /
    • 2011
  • Although peak loading coefficient is one of critical design factors for sewer works, its detailed affecting factors were not analyzed because of limited data availability. This study analyzed the affecting factors on peak loading coefficient with plenty data obtained from several newly constructed sewer works. Simple and multiple regression analysis methods were adopted to analyze the relationships of each variable with or without data filtering. Drainage population, drainage area, population density, and daily sewage flow per person showed very weak relationships under diverse characteristics of cities. However, daily sewage flow per person showed stronger relationships with peak loading when daily sewage flow per person was splitted into two ranges. Population density (i.e., drainage population divided by drainage area) and daily sewage flow per person considerably were related with peak loading coefficient when daily sewage flow per person is less than about 400 Lpcd.

Peak Factors for Bridges Subjected to Asynchronous Multiple Earthquake Support Excitations

  • Yoon, Chong-Yul;Park, Joon-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2011
  • Accurate response analysis of long span bridges subjected to seismic excitation is important for earthquake hazard mitigation. In this paper, the performance of a typical four span continuous reinforced concrete bridge model subjected to asynchronous multiple seismic excitations at the supports is investigated in both the time and frequency domains and the results are compared with that from a relevant uniform support excitations. In the time domain analysis, a linear modal superposition approach is used to compute the peak response values. In the frequency domain analysis, linear random vibration theory is used to determine the root mean square response values where the cross correlation effects between the modal and the support excitations on the seismic response of the bridge model are included. From the two sets of results, a practical range of peak factors which are defined to be the ratio of peak and the root mean square responses are suggested for displacements and forces in members. With reliable practical values of peak factors, the frequency domain analysis is preferred for the performance based design of bridges because of the computational advantage and the generality of the results as the time domain analysis only yields results for the specific excitation input.

Effect of critical flow model in MARS-KS code on uncertainty quantification of large break Loss of coolant accident (LBLOCA)

  • Lee, Ilsuk;Oh, Deogyeon;Bang, Youngseog;Kim, Yongchan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.755-763
    • /
    • 2020
  • The critical flow phenomenon has been studied because of its significant effect for design basis accidents in nuclear power plants. Transition points from thermal non-equilibrium to equilibrium are different according to the geometric effect on the critical flow. This study evaluates the uncertainty parameters of the critical flow model for analysis of DBA (Design Basis Accident) with the MARS-KS (Multi-dimensional Analysis for Reactor Safety-KINS Standard) code used as an independent regulatory assessment. The uncertainty of the critical flow model is represented by three parameters including the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio, and their ranges are determined using large-scale Marviken test data. The uncertainty range of the thermal non-equilibrium factor is updated by the MCDA (Model Calibration through Data Assimilation) method. The updated uncertainty range is confirmed using an LBLOCA (Large Break Loss of Coolant Accident) experiment in the LOFT (Loss of Fluid Test) facility. The uncertainty ranges are also used to calculate an LBLOCA of the APR (Advanced Power Reactor) 1400 NPP (Nuclear Power Plants), focusing on the effect of the PCT (Peak Cladding Temperature). The results reveal that break flow is strongly dependent on the degree of the thermal non-equilibrium state in a ruptured pipe with a small L/D ratio. Moreover, this study provides the method to handle the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio in the system code.

Electromagnetic Microactuators with the Electroplated Planar Coil Driven by Radial Magnetic Field (방사형 자기장 내의 전기도금된 평면코일을 이용한 전자기형 마이크로 액추에이터)

  • Ryu, Ji-Cheol;Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • This paper presents an electromagnetic microactuator using the copper coil electroplated on the p+silicon diaphragm. The microactuator generates a vertical motion of the diaphragm using the radial direction, we propose a new actuator structure with twin magnets. The microactuator field in the radial direction, we propose a new actuator structure with twin magnets. The microactator shows a values of resonant frequency and quality factor in the ranges of 10.51${\pm}$0.22kHz and 46.6${\pm}$3.3, respectively. The twin magnet microactuator generates the maximum peak-to-peak amplitude of 4.4$\mu\textrm{m}$ for the AC rms current of 26.8mA, showing 2.4 times larger amplitude than the single magnet microactuator.

A Study on Effect of Aerodynamic Loads on Mooring Line Responses of a Floating Offshore Wind Turbine (공기 동역학 하중이 부유식 해상 풍력 발전기의 계류선 응답에 미치는 영향에 관한 연구)

  • Kim, Hyungjun;Han, Seungoh;Choung, Joonmo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.1
    • /
    • pp.43-51
    • /
    • 2015
  • This paper presents effect of aerodynamic loads on mooring line responses of a floating offshore wind turbine. A Matlab code based on blade element momentum (BEM) theory is developed to consider aerodynamic loads acting on NREL 5MW wind turbine. The aerodynamic loads are coupled with time-domain hydrodynamic analyses using one-way interaction scheme of the wave and wind loads. A semi-submersible floating platform which is from Offshore Code Comparison Collaborative Continuation(OC4) DeepCWind platform is used with catenary mooring lines simply composed of studless chain links. Average values of mooring peak tensions obtained from aerodynamic load consideration are significantly increased compared to those from simple wind drag force consideration. Consideration of aerodynamic loads also yield larger tension ranges which can be important factor to reduce fatigue life of the mooring lines.

An Effect Absorption Property of Compound Absorption Structure on the Membranous and the Back Resonator type (표면재 및 배후 다공질재의 유형에 따른 복합 흡음구조의 흡음특성)

  • 김태훈;주문기;오양기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.65-71
    • /
    • 2001
  • Absorbers such as porous materials and panels have limited absorption characteristics to some frequency bands. There is a need for absorbers with high absorption coefficients in a wide frequency ranges to make good response of room acoustics. This is almost impossible for a single absorption material. Composite absorption structure with cover, porous material. and air gap is known to have those wide frequency characteristics. In this basis. various composite absorption structures are measured and investigated as wide range absorption structures. Measurements are performed according to an international standard, ISO 354. Various surface types such as wooden slits, wood/steel perforated panels are selected as surface covers, and also various porous materials such as polyurethanes, polyesters, and glasswools are used inside the covers. Result shows that the area of void parts of surface materials is critical to high frequency absorptions, and thickness of air gaps are critical factor of the peak absorptions of low frequency bands.

  • PDF

Characteristics of ITO Films Deposited by dc Magnetron Sputter Using Powder Target (분말타겟의 dc 마그네트론 스퍼터에 의한 ITO박막의 특성)

  • 김현후;신성호;신재혁;박광자
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.427-431
    • /
    • 2000
  • ITO (indium tin oxide) thin films on PET (polyethylene terephthalate) and glass substrates have been deposited by a dc magnetron sputtering without heat treatments such as substrate heater and post heat treatment. Each sputtering parameter during the sputtering deposition is an important factor for the high quality of ITO thin films deposited on polymeric substrate. Particularly, the material, electrical and optical properties of as-deposited ITO oxide films are dominated by sputtering power, oxygen partial pressure and films thickness. As the experimental results, the XRD patters of ITO films are influenced by sputtering power and pressure. As the power and pressure are increased, (411) peak is grown suddenly. the electrical resistivity is also increased, as the sputteing power and pressure are increased. Transmittance of ITO thin films in visible light ranges is lowered with increasing the sputtering power and film thickness. Reflectance of ITO films in infia-red region is decreased, as the power and pressure is increased.

  • PDF

Magnetic Field Strengths of Flaring Region in the Jet of CTA 102

  • Kim, Sang-Hyun;Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.32.1-32.1
    • /
    • 2021
  • We present the magnetic field strengths of CTA 102 using multi-frequency data at 2.6-343.5 GHz in order to study the physical origins of radio flares. The observations at 22 and 43 GHz were conducted using the single-dish radio telescopes of the Korean VLBI Network (KVN) from December 2012 until May 2018 (MJD 56200-58400). We used multi-frequency data obtained from the Effelsberg 100-m, OVRO 40-m, Metsähovi 14-m, IRAM 30-m, SMA, ALMA, and VLBA telescopes. During the period of the observations, two major flares (R1 and R2) are seen clearly at 15 and 37 GHz during MJD 57500-57800 and MJD 58000-58300, respectively. The source shows typical variability with time-scales ranging from 20-161 days at 15 GHz. The variability Doppler factor is in the range of 11.51-31.23. The quasi-simultaneous radio data are used to investigate the synchrotron spectrum of the source, finding that the synchrotron radiation is self-absorbed. The turnover frequency and the peak flux density of the synchrotron self-absorption (SSA) spectra are in ranges of 38.06-167.86 GHz and 1.49-10.38 Jy, respectively. From the SSA spectra, magnetic field strengths are estimated to be < 10 mG. The equipartition magnetic field strengths are larger than the SSA magnetic field strengths by a factor of > 100. This indicates that the radio flares may be related to a particle energy-dominated emission region.

  • PDF

Knee Strength and Ankle Range of Motion Influencing Gait Velocity and Gait Asymmetry in Patients With Chronic Stroke (만성 뇌졸중 환자의 보행속도와 보행 비대칭에 영향을 미치는 무릎근력과 발목 관절가동범위)

  • Won, Jong-Im;An, Chang-Man
    • Physical Therapy Korea
    • /
    • v.22 no.2
    • /
    • pp.1-10
    • /
    • 2015
  • The common features of walking in patients with stroke include decreased gait velocity and increased asymmetrical gait pattern. The purpose of this study was to identify important factors related to impairments in gait velocity and asymmetry in chronic stroke patients. The subjects were 30 independently ambulating subjects with chronic stroke. The subjects' impairments were examined, including the isokinetic peak torque of knee extensors, knee flexors, ankle plantarflexors, and ankle dorsiflexors. Passive and active ranges of motion (ROM) of the ankle joint, ankle plantarflexor spasticity, joint position senses of the knee and ankle joint, and balance were examined together. In addition, gait velocity and temporal and spatial asymmetry were evaluated with subjects walking at their comfortable speed. Pearson correlations and multiple regressions were used to measure the relationships between impairments and gait speed and impairments and asymmetry. Regression analyses revealed that ankle passive ROM and peak torque of knee flexors were important factors for gait velocity ($R^2=.41$), while ankle passive ROM was the most important determinant for temporal asymmetry ($R^2=.35$). In addition, knee extensor peak torque was the most significant factor for gait spatial asymmetry ($R^2=.17$). Limitation in ankle passive ROM and weakness of the knee flexor were major contributors to slow gait velocity. Moreover, limited passive ROM in the ankle influenced the level of temporal gait asymmetry in chronic stroke patients. Our findings suggest that stroke rehabilitation programs aiming to improve gait velocity and temporal asymmetry should include stretching exercise for the ankle joint.