• 제목/요약/키워드: Peak electric load

검색결과 173건 처리시간 0.03초

축냉시스템의 산업용 생산설비 적용에 대한 고찰 (Study on TES system application for industrial production facility)

  • 박창현;홍승수;김종률;박승상;황형식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

A SiC MOSFET Based High Efficiency Interleaved Boost Converter for More Electric Aircraft

  • Zaman, Haider;Zheng, Xiancheng;Yang, Mengxin;Ali, Husan;Wu, Xiaohua
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.23-33
    • /
    • 2018
  • Silicon Carbide (SiC) MOSFET belongs to the family of wide-band gap devices with inherit property of low switching and conduction losses. The stable operation of SiC MOSFET at higher operating temperatures has invoked the interest of researchers in terms of its application to high power density (HPD) power converters. This paper presents a performance study of SiC MOSFET based two-phase interleaved boost converter (IBC) for regulation of avionics bus voltage in more electric aircraft (MEA). A 450W HPD, IBC has been developed for study, which delivers 28V output voltage when supplied by 24V battery. A gate driver design for SiC MOSFET is presented which ensures the operation of converter at 250kHz switching frequency, reduces the miller current and gate signal ringing. The peak current mode control (PCMC) has been employed for load voltage regulation. The efficiency of SiC MOSFET based IBC converter is compared against Si counterpart. Experimentally obtained efficiency results are presented to show that SiC MOSFET is the device of choice under a heavy load and high switching frequency operation.

345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석 (Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.14-21
    • /
    • 1998
  • 본 논문에서는 평판형 전장센서와 멀티턴 루우프형 자장센서를 이용하여 2회선 345[kV] 송전선로에서 발생하 는 극저주파 영역(ELF)의 전장과 자장의 값을 측정하고, 이들의 크기를 3차원 그립으로 나타내었다. 또한, 자장 은 부하전류에 비례하므로 부하변동에 따른 자장의 값올 예측할 수 있도록 그 송전선로의 대표적인 일부하 전류 곡선을 나타내었다 선로 중심점으로부터 횡방향 거리에 대한 측정값을 FIELDS 프로그램에 의해 계산된 이론 값과 비교하였다. 전장의 세기는 송전 철탑 내부와 주변에서 낮게 나타났고, 자장의 경우 최대값이 나타난 지점 은 중부하 회선쪽으로 이동하였으나, 대체로 철탑의 중심부분에서 최대치가 나타나는 경향을 보였다. 송전철탑 주변에서 최대 전장과 자장의 값은 각각 3.5[kV/m]와 $20[{\mu}T]$ 를 초과하지 않았으며, 본 연구에서 측정된 전장과 자장의 값은 관련 여러 국제기관에서 제시한 제한.권고치를 만족시키고 있다.

  • PDF

축열식 지열원 히트펌프 시스템의 냉방기간 실증운전 결과 및 운영비용 분석 (Empirical Results and Operational Cost Analysis of Geothermal Heat Pump System using Thermal Energy Storage in Cooling Season)

  • 김득원;이동원;허재혁;김민휘
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.167-174
    • /
    • 2018
  • The geothermal heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. The heat pump system was operated at night to save on operational costs, and the cold heat was stored in thermal energy storage (TES). In this study, the performance of geothermal heat pump systems with the TES during the summer season was analyzed, and the operational costs with and without the TES were compared. The electric chiller model was used to simulate a heat pump applied without the TES system. Electric rates of each system were measured to calculate operational costs. When the TES is used in the air conditioning system, the electric load (30.4 MWh) calculated in the daytime can move to off-peak load time, and the operational cost is reduced by 36~54%.

전력수요관리를 위한 축냉식 냉방시스템 보급 및 기술개발 (Dissemination and Technical development of Cool Storage System for Demand Side Management)

  • 정금영;유재홍;유정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.856-857
    • /
    • 2007
  • For the sake of a stable power supply, an electric power company must have power generation facilities that can generate more electricity than the maximum demand of the year. Due to the fact that the maximum electricity demand will also continue to increase, enormous investments are needed annually to build power plants. For that reason, electric power companies are propelling 'Demand Side Management' which improve the form of electrical usage for the customer in a positive way. This paper presents the concept of 'Cool Storage System' which is the most representative program, which lowers the peak demand during the on-peak time periods in a day and creates a base load simultaneously during the night time hours among the DSM programs.

  • PDF

슬래브축열 공조시스템의 축열성능에 관한 실험적 연구 (An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

Experimental Study on Impact Loads Acting on Free-falling Modified Wigley

  • Hong, Sa-Young;Kim, Young-Shik;Kyoung, Jo-Hyun;Hong, Seok-Won;Kim, Yong-Hwan
    • International Journal of Ocean System Engineering
    • /
    • 제2권3호
    • /
    • pp.151-159
    • /
    • 2012
  • The characteristics of an impact load and pressure were experimentally investigated. Drop tests were carried out using a modified Wigley with CB = 0.56. The vertical force, pressures, and vertical accelerations were measured. A 6-component load cell was used to measure the forces, piezo-electric sensors were used to capture the impact pressure, and strain-gauge type accelerometers were used to measure the vertical accelerations. A 50-kHz sampling rate was applied to capture the peak values. The repeatability of the measured data was confirmed and the basic characteristics of the impact load and pressure such as the linearity to the falling height were observed for all of the measurements. A simple formula was derived to extract the physical impact load from the measured force based on a simple mass-sensor-mass diagram, which was validated by comparing impact forces with existing data using the mathematical model of Faltinsen and Chezhian (2005). The effects of the elasticity of the model and change in acceleration during the water entry were investigated. It is interesting to observe that the impact loads occurred and reached peak values at the same time duration after water entry for all drop heights.

대형상업건물의 열병합발전 부하조사 (A Survey on the Co-Generation Load for Large Commercial Buildings)

  • 한승호;권순우;정상원;정재혁
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.223-230
    • /
    • 1998
  • 서울특별시 소재 대형 상업건물중 50개 에너지 다소비업체를 선정하여 에너지 사용실태를 조사하였다. 조사대상 건물은 병원, 호텔, 백화점/사무실 등 3개 집단으로 분류하여 시설현황, 에너지사용량, 부하분포특성 등을 분석하였다. 여름철 냉방전력 사용량이 열부하 피크 발생에 직접적인 영향을 미치는 것으로 나타났으며 이를 열병합발전-흡수식 냉동기 방식으로 대체할 경우 전기부하 분포가 연간 비교적 일정하게 변환시킬 수 있어 열부하추종운전방식에 적합함을 알 수 있었다. 그러나, 단일건물의 경우 연간열부하분포가 경제적 규모에 미달하여 단독으로 열병합발전 설비를 도입하기에는 미흡한 점이 있어 다수건물을 대상으로 하는 공동 열병합발전 방식이 보다 유리한 것으로 판단된다. 이를 추진하기에는 전기사업법, 액화천연가스 요금체계 등과 같은 법제도의 정비가 선결되어야 할 것이다.

  • PDF

머신러닝기반 확률론적 실시간 건물에너지 수요예측 및 BESS충방전 기법 (Stochastic Real-time Demand Prediction for Building and Charging and Discharging Technique of ESS Based on Machine-Learning)

  • 양승권;송택호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.157-163
    • /
    • 2019
  • 현재까지 피크완화 및 에너지 절감을 위해 한국전력공사 120여개 사옥에 K-BEMS (KEPCO Building Energy Management System)가 운영 중이다. 이 시스템은 PV, PCS, BESS, EMS 등으로 구성되어 있으며 건물에너지 수요예측을 기반으로 BESS, PV 등을 활용하여 에너지 관리를 도모하고 있다. 이 시스템은 단기 과거데이터에 신경망기법을 단순 적용하여 수요를 예측함에 따라 예측 정확도가 높지 않고 운영자 수작업을 통한 BESS 충방전으로 피크 저감이 곤란하며 운영 경제성 제고가 어려운 실정이다. 이러한 문제를 해결하기 위해 전력연구원에서는 2016년부터 3년간 연구과제를 수행하였는데 이를 통해 에러를 최소화하며 높은 신뢰도를 가지는 실시간 수요예측기법과 이에 기반한 BESS충방전 최적화 자동화 기술 개발, 성능을 검증하였기에 이를 본 논문에서 소개하고자 한다.

빙축열 시스템의 제어를 위한 냉방부하 예측 (An Estimation of Cooling Load for Control of Ice Storage System)

  • 유성연;한승호;노관종;이제묘;강태석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.205-210
    • /
    • 2005
  • Ice storage system stores cold energy using ice, which is used for cooling on next day. Ice storage system is the effective cooling system that uses cheep electric energy during a night, and also suppresses the peak load of electricity. In this study, the normalized temperature, relative humidity and specific humidity are analyzed using the weather data for past five years in order to estimate the cooling load for the control of ice storage system. The calculated cooling loads show fairly good agreement with the measured data of model hospital, especially at the outdoor design temperature of $25^{\circ}C$.

  • PDF