• Title/Summary/Keyword: Peak current mode

Search Result 140, Processing Time 0.025 seconds

Single-Stage Double-Buck Topologies with High Power Factor

  • Pires, Vitor Fernao;Silva, Jose Fernando
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.655-661
    • /
    • 2011
  • This paper presents two topologies for single-stage single-phase double-buck type PFC converters, designed to operate at high power factor, near sinusoidal input currents and adjustable output voltage. Unlike the known buck type PFC topologies, in which the output voltage is always lower than the maximum input voltage, the proposed converters can operate at output voltages higher than the ac input peak voltage. A reduced number of switches on the main path of the current are another characteristic of the two proposed topologies. To shape the input line currents, a fast and robust controller based on a sliding mode approach is proposed. This active non-linear control strategy, applied to these converters allows high quality input currents. A Proportional Integral (PI) controller is adopted to regulate the output voltage of the converters. This external voltage controller modulates the amplitude of the sinusoidal input current references. The performances of the presented rectifiers are verified with experimental results.

Effect of Cu2+ Concentration and Additives on Properties of Electrodeposited Cu Thin Films for FCCL from Sulfate Baths (황산염용액으로부터 전기도금 된 FCCL용 Cu 필름의 특성에 미치는 Cu 이온농도 및 첨가제의 영향)

  • Shin, Dong-Yul;Park, Doek-Yong;Koo, Bon-Keup
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.191-196
    • /
    • 2009
  • Nanocrystalline Cu thin films were electrodeposited from sulfate baths and investigated systematically the influences of $Cu^{2+}$ concentration and additives on current efficiency, residual stress, surface morphology, and XRD patterns of electrodeposited Cu film. Current efficiency was nearly 100% at from 0.2M to 1.0 M $Cu^{2+}$ concentration. but it was linearly increased with $Cu^{2+}$ concentration at less than 0.2M. The residual stress was observed in range of 7.9 to 18.4 MPa and tensile stress mode. Dendritic and powdered form was obtained at below 0.1 M. As increased with $Cu^{2+}$ concentration in solution, the main peak in the XRD pattern shifted (111) and (220) from (200). In the other hand, all about 100% current efficiency observed in all additive concentration systems, and residual stress observed in range of 20.4 to 26.3 MPa tensile stress. The condition 5(Ultra make-up - 10 ml/l, Ulta A - 0.5ml/l, Ultr B - 0.5 ml/l) was good surface morphology, and fcc(111) peak in XRD patterns increased with increasing additive concentration.

The Effect of Current Pulsing Parameters on the Spatter Generation Rate during $CO_2$Shielded Gas Metal Arc Welding ($CO_2$ 용접에서 전류 펄스 조건이 스패터 발생에 미치는 영향)

  • 강덕일;최재호;장영섭;김용석
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.63-72
    • /
    • 1998
  • In this study, the effects of the current pulsing conditions, on the spatter generation rate during the $CO_2$ gas metal arc welding (GMAW) were investigated. Normally using the inverter type power supply, of which the welding current waveform was regulated to reduce the spatter generation rate, but in this study pulsing was imposed on the welding current. Observation of the metal transfer phenomena during the pulsed current GMAS indicated that the droplet transfer from the electrode via the short circuit transfer and the repelling transfer mode could be minimized by selecting optimum combinations of pulsing parameters, which include base and peak current, base and pak duration. It was also demonstrated in this study that proper combinations of the pulsing parameters led to reduce generation of spatters during GMAW shielded by $CO_2$ gas.

  • PDF

Resistive Current Mode Control for the Solar Array Regulator of SPACE Power System (인공위성 시스템을 위한 태양전지 전력조절기의 저항제어)

  • Bae, Hyun-Su;Yang, Jeong-Hwan;Lee, Jae-Ho;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.535-542
    • /
    • 2006
  • A large signal stability analysis of the solar array regulator system is performed to facilitate the design and analysis of a Low-Earth-Orbit satellite power system. The effective load characteristics of every controllable method in the solar array system are classified to analyze the large signal stability. Then, using the state plane analysis technique, the stability of various equilibrium points is analyzed. A nonlinear transformation algorithm, which changes the effective load characteristic of the solar array regulator as constant resistive load, is also proposed for the large signal stability. The proposed resistive current mode control system can control the solar array output for purposes such as peak power tracking control and battery charging control. For the verification of the proposed large signal analysis and resistive current mode control, a solar array regulator system consisting of two 100W parallel module buck converters has been built and tested using a real 200W solar array.

Pulse energy high Power test of metal film resistor (메탈 필름 저항의 펄스 대전력 시험)

  • Son, Y.G.;Jang, S.D.;Kwon, S.J.;Oh, J.S.;Cho, M.H.;Lee, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2103-2105
    • /
    • 2005
  • Metal film type of resistor have been tested to invest maximum usable power at the pulsed high voltage and pulsed high current. Experiments were carried out using capacitor charging power supply and dump switch. Pulsed amplitude were varied from 1kV to 25kV. The peak current reached was 1kA. Datasheet are given for the limited pulsed power and energy for metal film type of resistor in nanosecond and microsecond time range. The experimental investigation of the threshold loading of the resistor in the high current and voltage pulsed mode has shown that the process of destruction of resistor has specific features for each mode. The mechanisms of failure and destruction of resistors under action of high-voltage and high-current pulses are discussed.

  • PDF

Comparative Analysis of Current Controls for Boost PFC Converter under Light Load

  • Juil Kim;Yeong-Jun Choi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.143-151
    • /
    • 2024
  • In this paper, the inductor current distortion in a boost PFC (Power Factor Correction) converter under light load is mathematically analyzed, and its reasons are defined. In the average current mode control under light load, the inductor current is discontinuous, resulting in an inaccurate inductor current average value being reflected in the current control. In predictive current mode control, the current ripple is relatively large compared to the inductor current, leading to severe current distortion. In addition, the switch is turned off near the peak of the inductor current when model predictive current control is applied. Inductor current distortion must be addressed because it leads to an increase in total harmonic distortion and a decrease in power factor. In this paper, the design procedure to mitigate the light load current distortion in boost PFC converter is selected based on the mathematical analysis. Finally, a comparative analysis of control methods under light load is performed using hardware-in-the-loop simulation.

Analysis of the battery charging and discharging system for spacecrafts (인공위성용 총방전 시스템의 해석)

  • 김영태;김희진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.6
    • /
    • pp.932-942
    • /
    • 1995
  • A spacecraft power system can be divided into two types : DET system(Direct Energy Transfer system) and PPT system(Peak Power Tracking system). In a DET system employing the regulated bus voltage control method, the battery charger and discharger are widely used for the bus voltage regulation. The battery charger has two different modes of operation. One is the bus voltage regulation mode and the other is the charge current regulation mode. The battery discharger is employed to provide the power when the spacecraft is in the earth's shadow or the sun is eclipsed. The operating mode, charging or discharging, is selected by a power control circuit. In this paper, small-signal dynamic characteristics of battery charging and discharging system are analyzed to facilitate design of control loop for optimum performance. Control loop designs in various operating modes are discussed. Anaylses are verified through experiments.

  • PDF

Fast Intra Mode Decision using Transform Coefficients (변환 계수를 이용한 고속 인트라모드 결정법)

  • Hwang Gyu-Yong;Park Jong-Bin;Jeon Byeung-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.255-258
    • /
    • 2006
  • In the H.264/AVC standard, intra prediction increases the coding efficiency of intra macroblocks and by applying rate-distortion optimization to each macroblock, it is possible to choose Inter or Intra encoding adaptively. This sort of encoding scheme, however, increases encoding complexity dramatically and causes troubles in practical applications of the real-time mobile environment. In order to decrease the complexity, variety of methods is proposed but most of those take only its current block into consideration for selecting candidate modes which naturally causes degradation in PSNR (Peak Signal to Noise Ratio). The proposed fast intra mode decision finds the candidate modes by analyzing transformed coefficients of neighboring blocks stored in the buffer at the encoder stage of input sequences. We verify this proposed scheme in complexity, PSNR and bit-rate.

  • PDF

Transformer-Reuse Reconfigurable Synchronous Boost Converter with 20 mV MPPT-Input, 88% Efficiency, and 37 mW Maximum Output Power

  • Im, Jong-Pil;Moon, Seung-Eon;Lyuh, Chun-Gi
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.654-664
    • /
    • 2016
  • This paper presents a transformer-based reconfigurable synchronous boost converter. The lowest maximum power point tracking (MPPT)-input voltage and peak efficiency of the proposed boost converter, 20 mV and 88%, respectively, were achieved using a reconfigurable synchronous structure, static power loss minimization design, and efficiency boost mode change (EBMC) method. The proposed reconfigurable synchronous structure for high efficiency enables both a transformer-based self-startup mode (TSM) and an inductor-based MPPT mode (IMM) with a power PMOS switch instead of a diode. In addition, a static power loss minimization design, which was developed to reduce the leakage current of the native switch and quiescent current of the control blocks, enables a low input operation voltage. Furthermore, the proposed EBMC method is able to change the TSM into IMM with no additional time or energy loss. A prototype chip was implemented using a $0.18-{\mu}m$ CMOS process, and operates within an input voltage range of 9 mV to 1 V, and an output voltage range of 1 V to 3.3 V, and provides a maximum output power of 37 mW.

Design of a Low-Power CMOS Analog Front-End Circuit for UHF Band RFID Tag Chips (UHF 대역 RFID 태그 칩을 위한 저전력 CMOS 아날로그 Front-End 회로 설계)

  • Shim, Hyun-Chul;Cha, Chung-Hyun;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.28-36
    • /
    • 2008
  • This paper describes a low-power CMOS analog front-end block for UHF band RFID tag chips. It satisfies ISO/IEC 18000-6C and includes a memory block for test. For reducing power consumption, it operates with an internally generated power supply of 1V. An ASK demodulator using a current-mode schmitt trigger is proposed and designed. The proposed demodulator can more exactly demodulate than conventional demodulator with low current consumption. It is designed using a $0.18{\mu}m$ CMOS technology. Measurement results show that it can operate properly with an input as low as $0.25V_{peak}$ and consumes $2.63{\mu}A$. The chip size is $0.12mm^2$.