• 제목/요약/키워드: Peak current density

검색결과 239건 처리시간 0.027초

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

게이트 리세스 식각 방법에 따른 PHEMT 특성 변화 (Analysis of characteristics of PHEMT's with gate recess etching method)

  • 이한신;임병옥;김성찬;신동훈;전영훈;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.249-252
    • /
    • 2002
  • we have studied the characteristics of PHEMT's with gate recess etching method. The DC characterization of PHTMT fabricated with the wide single recess methods is a maximum drain current density of 319.4 ㎃/mm and a peak transconductance of 336.7 ㎳/mm. The RF measurements were obtained in the frequency range of 1~50GHz. At 50GHz, 3.69dB of 521 gain were obtained and a current gain cut-off frequency(f$_{T}$) of 113 CH and a maximum frequency of oscillation(f$_{max}$) of 172 Ghz were achieved from this device. On the other hand, a maximum drain current of 367 mA/mm, a peak transconduclancc of 504.6 mS/mm, S$_{21}$ gain of 2.94 dB, a current gain cut-off frequency(f$_{T}$) of 101 CH and a maximum frequency of oscillation(f$_{max}$) of 113 fa were achieved from the PHEMT's fabricated by the .narrow single recess methods.methods.

  • PDF

폴리플로필렌 박막의 전기적 특성에 관한 연구 (A study on the Electrical Properties of Polypropylene Film)

  • 이준웅;김왕곤;김봉야
    • Elastomers and Composites
    • /
    • 제21권2호
    • /
    • pp.121-128
    • /
    • 1986
  • Studies has been carried out on the characteristics of thermally stimulated current for polypropylene in the temperature range of $293[^{\circ}K]{\sim}403[^{\circ}K]$. The main peak observed at $366[^{\circ}K]$, as may be $\beta$ peak in conventional nomination, is believed to be depolarization current originated from the relaxation of "CO" group in monomer structure. The activation energy for the observed peak has been concluded to be in the range of $0.6{\sim}0.7[(eV]$ at $360[^{\circ}K]$ by the initial rise method. Furthermore, the initial density of carriers were calculated about $10^{22}/m^3$

  • PDF

A SiC MOSFET Based High Efficiency Interleaved Boost Converter for More Electric Aircraft

  • Zaman, Haider;Zheng, Xiancheng;Yang, Mengxin;Ali, Husan;Wu, Xiaohua
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.23-33
    • /
    • 2018
  • Silicon Carbide (SiC) MOSFET belongs to the family of wide-band gap devices with inherit property of low switching and conduction losses. The stable operation of SiC MOSFET at higher operating temperatures has invoked the interest of researchers in terms of its application to high power density (HPD) power converters. This paper presents a performance study of SiC MOSFET based two-phase interleaved boost converter (IBC) for regulation of avionics bus voltage in more electric aircraft (MEA). A 450W HPD, IBC has been developed for study, which delivers 28V output voltage when supplied by 24V battery. A gate driver design for SiC MOSFET is presented which ensures the operation of converter at 250kHz switching frequency, reduces the miller current and gate signal ringing. The peak current mode control (PCMC) has been employed for load voltage regulation. The efficiency of SiC MOSFET based IBC converter is compared against Si counterpart. Experimentally obtained efficiency results are presented to show that SiC MOSFET is the device of choice under a heavy load and high switching frequency operation.

Ag Pulse 도금을 이용한 표면 형상 및 특성 변화에 대한 연구

  • 정대희;김정수;조대형;유봉영
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.90.1-90.1
    • /
    • 2012
  • 1934년 J. R. Winkler에 의해 처음으로 개발된 pulse current 도금은 연속적인 직류 단속을 이용한 전기도금으로써 종래의 연속적인 직류(direct current) 전기 도금이 가지는 다공성 및 거친 도금 등의 한계를 극복하기 위해 연구되고 있다. 최근 전기 전자 산업의 급속한 발달과 함께 Au, Pd, Rh 등의 귀금속 도금에 있어서 Pulse 도금은 광택, 다공도, 내부 응력, 불순물 및 수소 함유량의 감소와 같은 특성 향상을 가질 수 있으며 기존 DC 전기 도금의 문제점 해결책으로서 많은 연구가 이루어지고 있다. 하지만 현재까지 Pulse 도금의 정확한 기구(mechanism)에 대한 명확한 정립이 되어 있지 않아 모든 도금계에 적용할 수 있는 standard pattern이 없는 실정이다. 본 연구에서는 귀금속 도금 중 Ag pulse 도금에 있어서 Peak current density, duty cycle, time이 Ag 도금의 표면 형상, 두께, 열전도율에 미치는 영향에 대해 연구하였다.

  • PDF

Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA)

  • 손윤희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

고분자물질들의 분극 특성: Poly(vinylchloride), Poly(ethyleneterephthalate), Poly(propylene), Poly(carbonate) (Polarization Characteristics of Polymers: Poly(vinylchloride), Poly(ethyleneterephthalate), Poly(propylene), and Poly(carbonate))

  • 최칠남;양효경
    • 대한화학회지
    • /
    • 제46권1호
    • /
    • pp.19-25
    • /
    • 2002
  • 우리는 고분자 물질들에 대해서 전위와 전류 밀도의 변화를 측정하였다. 온도와 pH를 포함하여 전위와 속도에 대한 영향을 주는 여러 요인들에 밝히기 위하여, 연구 결과들이 주위 깊게 조사되었다. 양극 해리에 대한 Tafel 기울기는 이들 조건 하에서 분극 효과로 결정되었다. 각 경우에 최적 조건들이 확립되었다. 두 번째 양극 전류 밀도 피크와 최대 전류 밀도는 상대적 분극 감도$(I_r/I_f)$로 지정되었다. 최적 조건에서의 분극 효과를 바탕으로, 질량 전달 계수$({\alpha})$는 양극 해리에 대한 Tafel 기울기에 의해서 결정되었다.

연성 기판을 전류 집전체로 사용한 평판형 연료전지 스택 (Miniature planar stack using the flexible Printed Circuit Board as current collectors)

  • 김성한;차혜연;;차석원;장재혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2008
  • Fuel cells have the potential of providing several times higher energy storage densities than those possible using current state-of-the-art lithium-ion batteries, but current energy density of fuel cell system is not better than that of lithium-ion batteries. To achieve the high energy density, volume and weight of fuel cell system need to be reduced by miniaturizing system components such as stack, fuel tank, and balance-of-plant. In this paper, the thin flexible PCB (Printed circuit board) is used as a current collector to reduce the stack volume. Two end plates are made from light weight aluminum alloy plate. The plate surface is wholly oxidized through the anodizing treatment for electrical insulation. The opening rate of cathode plate hole is optimized through unit cell performance measurement of various opening rates. The performances are measured at room temperature and ambient pressure condition without any repulsive air supply. The active area of MEA is 10.08 $cm^2$ and active area per a unit cell is 1.68 $cm^2$. The peak power density is about 210 mW/$cm^2$ and the air-breathing planar stack of 2 Wis achieved as a small volume of 18 cc.

  • PDF

냉음극형 대면적 전자빔의 공간적 분포 특성 (Characteristics of spatial distribution of cold cathode type large aperture electron beam)

  • 우성훈;;조주현;김광훈;이홍식;임근희;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2170-2172
    • /
    • 1999
  • A low energy large aperture(LELA) pulsed electron beam generator of a cold cathode type has been developed for environmental applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. We have fabricated the LELA electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large aperture electron beam in air. The electron beam current density has been investigated as a function of glow discharge current, accelerating voltage and radial distribution in front of the exit window foil. The plasma density and electron temperature have been measured in order to confirm the relation with the electron beam current density. We are going to upgrade the LELA electron beam generator in the electron energy, electron beam current and stability of operation for various applications.

  • PDF