• Title/Summary/Keyword: Peak Discharge

Search Result 624, Processing Time 0.03 seconds

A Case Study of Extensive Green Roof System for Tropical Climate in Malaysia

  • Kok, Kah Hoong;Jung, Kwansue;Sidek, Lariyah Mohd;Abidin, Mohd Roseli Zainal;Felix, Micah Lourdes
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.329-329
    • /
    • 2016
  • Rapid urbanization has taken environmental toll on the surrounding which can be witnessed by the advent of global warming and climate change. Driven by environmental needs, Green Building Index (GBI) was established in Malaysia to drive initiative to lead the property industry towards becoming more environmental friendly. Green roofs (roof with vegetated cover) as one of the assessment criteria of GBI, are gaining attention in the Malaysian society as a versatile new environmental friendly mitigation technology. This paper evaluates the qualitative and quantitative performances of an extensive green roof at Humid Tropics Centre under local tropical climate. Simulations showed that the extensive green roof system could reduce the peak discharge up to 26% in relation to impervious brown roof. Its reduction ability decreased for storms with intense rainfall. Increment of pH was observed for the green roof runoff and the runoff water quality ranged between class I and II under Water Quality Index (WQI). High concentrations of phosphate were noticed in the runoff samples and substrates (fertilized planting soil) might be the potential contributor. Findings indicate that there was a reduction of around $1.5^{\circ}C$ for indoor temperature of the building after installation of the extensive green roof.

  • PDF

An Application of Realistic Evaluation Model to the Large Break LOCA Analysis of Ulchin 3&4

  • C. H. Ban;B. D. Chung;Lee, K. M.;J. H. Jeong;S. T. Hwang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.429-434
    • /
    • 1996
  • K-REM[1], which is under development as a realistic evaluation model of large break LOCA, is applied to the analysis of cold leg guillotine break of Ulchin 3&4. Fuel parameters on which statistical analysis of their effects on the peak cladding temperature (PCT) are made and system parameters on which the concept of limiting value approach (LVA) are applied, are determined from the single parameter sensitivity study. 3 parameters of fuel gap conductance, fuel thermal conductivity and power peaking factor are selected as fuel related ones and 4 parameters of axial power shape, reactor power, decay heat and the gas pressure of safety injection tank (SIT) are selected as plant system related ones. Response surface of PCT is generated from the plant calculation results and on which Monte Carlo sampling is made to get plant application uncertainty which is statistically combined with code uncertainty to produce the 95th percentile PCT. From the break spectrum analysis, blowdown PCT of 1350.23 K and reflood PCT of 1195.56 K are obtained for break discharge coefficients of 0.8 and 0.5, respectively.

  • PDF

Development of machine learning model for automatic ELM-burst detection without hyperparameter adjustment in KSTAR tokamak

  • Jiheon Song;Semin Joung;Young-Chul Ghim;Sang-hee Hahn;Juhyeok Jang;Jungpyo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.100-108
    • /
    • 2023
  • In this study, a neural network model inspired by a one-dimensional convolution U-net is developed to automatically accelerate edge localized mode (ELM) detection from big diagnostic data of fusion devices and increase the detection accuracy regardless of the hyperparameter setting. This model recognizes the input signal patterns and overcomes the problems of existing detection algorithms, such as the prominence algorithm and those of differential methods with high sensitivity for the threshold and signal intensity. To train the model, 10 sets of discharge radiation data from the KSTAR are used and sliced into 11091 inputs of length 12 ms, of which 20% are used for validation. According to the receiver operating characteristic curves, our model shows a positive prediction rate and a true prediction rate of approximately 90% each, which is comparable to the best detection performance afforded by other algorithms using their optimized hyperparameters. The accurate and automatic ELM-burst detection methodology used in our model can be beneficial for determining plasma properties, such as the ELM frequency from big data measured in multiple experiments using machines from the KSTAR device and ITER. Additionally, it is applicable to feature detection in the time-series data of other engineering fields.

A Sensitivity of Simulated Runoff Characteristics on the Different Spatial Resolutions of Precipitation Data (강우자료의 공간해상도에 따른 모의 유출특성 민감도 고찰)

  • Lee, Dogil;Hwang, Syewoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.6
    • /
    • pp.37-49
    • /
    • 2023
  • Rainfall data is one of the most important data in hydrologic modeling. In this study, the impacts of spatial resolution of precipitation data on hydrological responses were assessed using SWAT in the Santa Fe River Basin, Florida. High correlations were found between the FAWN and NLDAS rainfall data, which are observed weather data and simulated weather data based on observed data, respectively. FAWN-based scenarios had higher maximum rainfall and more rainfall days and events compared to NLDAS-based scenarios. Downstream areas showed lower correlations between rainfall and peak discharge than upstream areas due to the characteristics of study site. All scenarios did not show significant differences in base flow, and showed less than 5% of differences in high flows among NLDAS-based scenarios. The impact of resolution will appear differently depending on the characteristics of the watershed and topography and the applied model, and thus, is a process that must be considered in advance in runoff simulation research. The study suggests that applying the research method to watersheds in Korea may yield more pronounced results, and highlights the importance of considering data resolution in hydrologic modeling.

CMI Tolerant Readout IC for Two-Electrode ECG Recording (공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로)

  • Sanggyun Kang;Kyeongsik Nam;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Effect of Al and Nb Doping on the Electrochemical Characteristics of Garnet-type Li7La3Zr2O12 Solid Electrolytes

  • Ahmed Tarif;Chan-Jin Park
    • Corrosion Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.408-418
    • /
    • 2023
  • In this study, we synthesized and characterized garnet-type Li7-xAlxLa3Zr2-(5/4)yNbyO12 (LALZN) solid electrolytes for all-solid-state battery applications. Our novel approach focused on enhancing ionic conductivity, which is crucial for battery efficiency. A systematic examination found that co-doping with Al and Nb significantly improved this conductivity. Al3+ and Nb5+ ions were incorporated at Li+ and Zr4+ sites, respectively. This doping resulted in LALZN electrolytes with optimized properties, most notably enhanced ionic conductivity. An optimized mixture with 0.25 mol each of Al and Nb dopants achieved a peak conductivity of 1.32 × 10-4 S cm-1. We fabricated symmetric cells using these electrolytes and observed excellent charge-discharge profiles and remarkable cycling longevity, demonstrating the potential for long-term application in battery systems. The garnet-type LALZN solid electrolytes, with their high ionic conductivity and stability, show great potential for enhancing the performance of all-solid-state batteries. This study not only advances the understanding of effective doping strategies but also underscores the practical applicability of the LALZN system in modern energy storage solutions.

A Methodology for the Estimation of Design Flood of a Small Watershed (소하천유역(小河川流域)의 계획홍수량(計劃洪水量) 산정방법(算定方法)의 개발(開發))

  • Yoon, Yong Nam;Ahn, Tae Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.103-112
    • /
    • 1984
  • This study is an effort to develop a series of empirical procedure for the determination of design flood for a small watershed based on the unit hydrograph theory. It is shown that a flood discharge of a watershed with a specific return period can be expressed as a product of its watershed area, rainfall factor, runoff factor and flood peak reduction factor. Since the procedures for the determination of rainfall factor and runoff factor were already developed in the previous study (13) a series of step-by-step procedure is devised to empirically determine the flood peak reduction factor in the present study. Using the methodology developed herein the 50-year design flood, which is of concern in the drainage of agricultural lands, is estimated for a watershed on upper Kyungan River and compared with the design floods by the existing methods now in use. The flood peak reduction factor was correlated with the dimensionless parameter consisted of the rainfall duration divided by the basin lag time, which was computed from the derived unit hydrographs by the method of moment. The unit hydrographs of various durations were synthesized by the method of build up and S-curve. A multiple correlation was also made between the basin lag time and the physiographic parameters of the watershed, i.e., the stream length and the average stream slope.

  • PDF

An Esitimation of Lognitudinal Dispersion Coefficient in Natural Stram Using Hydraulic Model (수리모형을 이용한 자연하천에서 종확산계수 추정)

  • Yun, Se-Ui;Han, Geon-Yeon;Han, Jeong-Seok;Kim, Jeong-Su
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.4
    • /
    • pp.407-417
    • /
    • 2000
  • To estimate the longitudinal dispersion coefficient at the downstream of Jungrang-River, the undistorted 1/20 scale hydraulic model was used in this study. Experiments were conducted for dry season discharge, and Rhodamine B was used as a tracer. The relationship curve between concentration and conductivity of Rhodamine B was otained by laboratory test, and the conductivity which was measured in hydraulic model was converted to concentration using this curve. The longitudinal dispersion coefficient was calculated using the relationship between the peak concentration and the time to peak concentration. The results of this study were compared with the calculated values by the empirical equations for the longitudinal dispersion coefficient and with the field data. The results of comparison show that Parker's equation underestimates, and Liu'g equation and Iwasa and Aya's one overestimate, and McQuivey and Keefer's equations, Fischer's one, Magazine's one, and Seo and Cheong's one predict relatively well. The measured data sets were relatively close to the observed ones in natural river. The longitudinal dispersion coefficient at the downstream of Jungrang-River was estimated $10\textrm{m}^2/s$.

  • PDF

수처리 목적의 대기압플라즈마를 이용한 유사 폴리도파민 필름 증착

  • Mun, Mu-Gyeom;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.124-124
    • /
    • 2018
  • Polydopamine은 수중 접착력, 친환경 접착제, nanoparticle absorption 등 다양한 특성으로 많이 연구되고 있는 소재이다. 본 연구에서는 dopamine을 이용하여 수중 금속을 흡착시키는 thin film을 제작하였다. 종래의 Polydopamine coating 방법으로 wet coating 이 사용되고 있다. 하지만 wet 방식의 경우 시간이 오래 걸릴 뿐만 아니라 in-line, roll to roll 방식을 적용하는 것이 어렵기 때문에 생산적이지 않다. 이에 본 연구에서는 Atmospheric Pressure Plasma(APP)를 이용 하여 Polydopamine-like film을 coating 하였다. APP의 경우 vacuum system, solution tank가 필요 없고 in-line, roll to roll 방식을 적용 할 수 있기 때문에 더 경제적이고 생산적인 공정이다. 또한 기존의 Plasma polymerization 방법은 Plasma energy가 높기 때문에 source의 분자구조가 바뀌거나 atom 단위로 분해된다. source의 분자구조가 바뀌는 "Atomic polymerization", Neiswender-Rosskamp Mechanism이 적용되면 wet 방식 coating한 film과는 다른 특성을 갖게 된다. 하지만 APP polymerization은 Plasma energy가 vacuum plasma 보다 매우 낮기 때문에 stile polymerization mechanism을 구현 하는데 적합 하다. stile polymerization mechanism은 Plasma 내부에서 polymer source를 분해 성장 시켜서 Polymer film 얻는 것이 아닌 source의 분자구조가 깨지지 않으면서 polymer growing 시키는 방법이다. dopamine source의 분자구조를 최대한 유지하려고 하는 이유는 metal absorption과 같은 특성이 dopamine chemical structure에 영향을 받기 때문이다. 많은 논문들에서 dopamine의 catechol group이 metal absorption, adhesion force에 영향을 주는 주요 인자라고 주장하고 있기 때문이다. 그래서 본 논문에서는 Dopamine source의 형태를 보존하면서 Polymerization 하는 방법으로 APP process를 사용 하여 낮은 전압에서 Polydopamine-like film을 제작 하였다. APP system 의 Plasma 방전부 에 Dopamine source를 유입하기 위하여 본 논문에서는 Piezo Spray 방식을 사용 하였다. Dopamine을 evaporator 하는 것이 어렵고 chemical composition이 유사한 monomer를 사용해서 Plasma Polymerization으로 Dopamine 분자 구조를 재현하는 것도 어렵다. 그래서 본 연구에서는 Dopamine을 water에 immerse 하고 Dopamine solution을 mist 상태로 만들어서 Plasma discharge area에 유입하였다. 이러한 방법으로 만들어진 film은 Polydopamine film은 아니지만 Polydopamine film과 유사한 Chemical composition, chemical structure, metal absorption을 갖는 것을 FT-IR, SEM, XPS을 이용 하여 확인 하였다. Dopamine source의 보존에 대하여 명확하게 확인하기 위하여 FT-IR을 측정 하였다. 전압에 따른 Benzene ring, hydroxyl group의 비율을 확인 하였다. 낮은 전압으로 coating 된 Polydopamine-like film 일수록 hydroxyl group peak($3400{\sim}3000cm^{-1}$)과 비교하여 Benzene ring peak($1600{\sim}1580cm^{-1}$ and $1510{\sim}500cm^{-1}$)이 흡수를 더 많이 하는 것을 확인 할 수 있다. 이것은 Benzene ring이 파괴되지 않고 보존되는 것을 보여준다. Dopamine에서 Benzene ring은 absorption main factor인 catechol에 있는 chemical structure이다. 즉 Benzene ring peak이 높을수록 Catechol이 잘 보존 되었다는 의미 이다. Catechol의 보존은 absorption main factor가 보존 된다는 의미 이다. 이러한 Polydopamine-like film으로 As, Cr, Mg, Cu 200ppm solution에 대한 filtration 능력을 확인 하였다. As, Cr, Cu, Mg 의 제거율이 각각 약25%, 35%, 45%, 65%인 것을 확인 하였다. 이 수치는 시중에 판매되는 제품들과 비교했을 때 300%~500% 향상된 수치 이다.

  • PDF

Comparison of meridians electric response property for laser and acupuncture stimulation (레이저자극과 수기자극에 대한 경락전기반응 특성비교)

  • Lee, Yong-Heum;Ryu, Yeon-Hang;Jung, Byoung-Jo;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2335-2342
    • /
    • 2007
  • Laser stimulation has been widely studied and used in clinic. However, electrical response by laser stimulation on meridians has not been investigated. In this study, we compared electric potential of laser and acupuncture stimulation on meridians. We measured electric potential variation at acupoints(Samgan(LI3) and Hapgok(LI4)) on Large Intestine Meridian. In laser stimulation results, average peak electric potential is very low($7.53{\pm}3.44{\mu}V$) for before and after stimulation. However, acupuncture stimulation was performed in ground connection condition and resulted in huge variation of average peak electric potential($2.65{\pm}1.53mV$). That is, the intensity and pattern of electric potential were dependent on the ground connection condition and individual. Also, the electric potential pattern was very similar to the pattern of electric charge and discharge of capacitor. The acupuncture stimulation using a insulating needle resulted in lower average peak electric potential variation($0.25{\pm}0.16mV$) than that of acupuncture stimulation. It might present little electrical response of acupuncture stimulation using insulating needles. In point of electrical response, the laser stimulation was determined to be no acupuncture effect at meridian. Acupuncture stimulation seems to be most effective method to induce electrical response at meridians. The procedure and effect of acupuncture might be considered as energy consensus phenomenon by transportation of bio-ion charge between a practitioner and patient.