• Title/Summary/Keyword: Peak Discharge

Search Result 624, Processing Time 0.027 seconds

A Study on the Texturing Characteristics of Work Roll and Variation of Strip Surface Roughness in 4-Hi Mill (4단 압연기용 작업롤의 표면조도가공 특성과 판면조도 변화에 관한 연구)

  • Kim, Moon Kyung;Jeon, Eon Chan;Kim, Soon Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.7
    • /
    • pp.167-175
    • /
    • 1996
  • Work roll wear in the cold rolling of steel strip is strongly affected by rolling materials, rolling conditions and lubrication. Tests were performed to find the effects of rolling materials under the same lubricating conditions. Surface roughness of cold rolled steel strip as well as the coating technique itself is quite improtant in obtaining high image clarity of electronic products and car outer panels. Therefore this paper reviews for improvement of roughness and peak count about the surface of Cr coated work roll is investigated from the actual temper mill. The conclusions were obtained as follows; 1) Work roll wear in the cold rolling of steel strip is strongly affected by carbon contents of rolling materials, but there is not a separating force and total reduction ratio. 2) The roughness of strip surface is larger in the direction of width than in roll direction. 3) The electro-discharge textured roll has more uniform roughness distribu- tion than shot blasted roll and it's life time is two times longer than shot blasted because it has more harmonic wave roughness, and the higher peak count of surface roughness. 4) The life time of Cr coated work roll is 2 times longer than that of shot blasted work roll and variation of peak count, roughness and life time of Cr coated work roll is similar to electro-discharge texturing work roll. 5) The proper Cr coating thickness is 10 .mu. m at the work roll of temper mill.

  • PDF

Determination of EDM Parameters from CMM Data (CMM 데이터로부터 방전조건 결정)

  • 주상윤
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.35-39
    • /
    • 1998
  • Determination of effective EDM parameters is significant to increase productivity. However, With the complexity of EDM phenomena, a universal selection method of EDM parameters has not been established yet. Moreover, No attempt has been tried before to suggest a logical method in determining essential machining parameters for effective electrical discharge machining. Peak current, one of the most significant factors in EDM, is proportional to EDM area. This paper presents a method that can be Z-map modeling from CMM data, and calculate EDM area using Z-map.

  • PDF

Performance Evaluation of the Runoff Reduction with Permeable Pavements using the SWMM Model (SWMM 분석을 통한 투수성 포장의 유출 저감 특성 평가)

  • Lin, Wuguang;Ryu, SungWoo;Park, Dae Geun;Lee, Jaehoon;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.11-18
    • /
    • 2015
  • PURPOSES: This study aims to evaluate the runoff reduction with permeable pavements using the SWMM analysis. METHODS: In this study, simulations were carried out using two different models, simple and complex, to evaluate the runoff reduction when an impermeable pavement is replaced with a permeable pavement. In the simple model, the target area for the analysis was grouped into four areas by the land use characteristics, using the statistical database. In the complex model, simulation was performed based on the data on the sewer and road network configuration of Yongsan-Gu Bogwang-Dong in Seoul, using the ArcGIS software. A scenario was created to investigate the hydro-performance of the permeable pavement based on the return period, runoff coefficient, and the area of permeable pavement that could be laid within one hour after rainfall. RESULTS : The simple modeling analysis results showed that, when an impervious pavement is replaced with a permeable pavement, the peak discharge reduced from $16.7m^3/s$ to $10.4m^3/s$. This represents a reduction of approximately 37.6%. The peak discharge from the whole basin showed a reduction of approximately 11.0%, and the quantity decreased from $52.9m^3/s$ to $47.2m^3/s$. The total flowoff reduced from $43,261m^3$ to $38,551m^3$, i.e., by approximately 10.9%. In the complex model, performed using the ArcGIS interpretation with fewer permeable pavements applicable, the return period and the runoff coefficient increased, and the total flowoff and peak discharge also increased. When the return period was set to 20 years, and a runoff coefficient of 0.05 was applied to all the roads, the total outflow reduced by $5195.7m^3$, and the ratio reduced to 11.7%. When the return period was increased from 20 years to 30 and 100 years, the total outflow reduction decreased from 11.7% to 8.0% and 5.1%, respectively. When a runoff coefficient of 0.5 was applied to all the roads under the return period of 20 years, the total outflow reduction was 10.8%; when the return period was increased to 30 and 100 years, the total outflow reduction decreased to 6.5% and 2.9%, respectively. However, unlike in the simple model, for all the cases in the complex model, the peak discharge reductions were less than 1%. CONCLUSIONS : Being one of the techniques for water circulation and runoff reduction, a high reduction for the small return period rainfall event of penetration was obtained by applying permeable pavements instead of impermeable pavement. With the SWMM analysis results, it was proved that changing to permeable pavement is one of the ways to effectively provide water circulation to various green infrastructure projects, and for stormwater management in urban watersheds.

Analysis of the Direct Runoff by Using the Geomorpologic Parameters of Watersheds (유역(流域)의 지상인자(地上因子)를 이용(利用)한 홍수량(洪水量) 해석(解析))

  • Suh, Seung Duk;Lee, Seung Yook
    • Current Research on Agriculture and Life Sciences
    • /
    • v.7
    • /
    • pp.55-66
    • /
    • 1989
  • The purpose of this study is to estimate the flood discharge and peak time by the SCS method and the probability method using the geomorpologic parameters obtained from the topographic maps following the law of stream classifying and, ordering by Horton and Strahler. The SCS method and the probability method are used in estimating the times to peak and the flood discharges at An-dong, Im-ha, and Sun-san basins in the Nakdong River system. The results obtained are as follows : 1. The range of the values of the area ratio, the bifurcation ratio and the length ratio agree with those of natural streams presented by Horton and Strahler. 2. Comparisons of the probability method and observed values show that small relative errors of 0-7% of flood discharge, and 0-2hr, difference in time to peak respectivly. But the SCS method shows that large relative errors of 10-40% of flood discharge, and 0-4hr, difference in time to peak. 3. When the rainfall intensity is large, the error of flood discharge estimated by using the probability method is relativly small.

  • PDF

The furulamelllal study in order to obtain the hydrological design basis for hydrological structures in Korea (Run ofl estimate and Flood part) (한국에 있어서 제수문구조물의 설계의 기준을 주기 위한 수문학적 연구(류거, 홍수 편))

  • 박성우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.8 no.1
    • /
    • pp.1011-1034
    • /
    • 1966
  • This thesis is the final report which has long been studied by the author to obtain the design basis for various hydrological constructions with the specific system suitable to the natural environmental conditions in Korea. This report is divided into two parts: one is to estimate runoff volume from watersheds and the other to estimate the peak discharge for a single storm. According to the result of observed runoff record from watersheds, it is known that Kajiyama formula is useful instrument in estimating runoff volume from watersheds in this country. But it has been found that this formula shows us 20-30% less than the actual flow. Therefore, when wihed to bring a better result, the watershed characteristics coefficient in this formula, that is, f-value, should be corrected to 0.5-0.8. As for the method to estimate peak discharge from drainage basin, the author proposes to classify it in two ways; one is small size watershed and the other large size watershed. The maximum -flood discharge rate $Q_p$ and time to peak Pt obtained from the observed record on the small size watershed are compared by various methods and formulas which are based upon the modern hydrological knowledge. But it was fou.d that it. was not a satisfied result. Therefore, the author proposes. tocomputate $Q_p$, to present 4.0-5.0% for the total runoff volume ${\Sigma}Q$.${\Sigma}Q$ is computed under the assumption of 30mm 103s in watershed per day and to change the theoritical total flow volume to one hour dura tion total flow rate when design daily storm is given. Time to peak Pt is derived from three parameters which are u,w,k. These are computed by relationship between total runoff volume (ha-m unit)and $Q_p$. (C.M.S. unit). Finally, the author checked out these results obtained from 51 hydrographs and got a satisfied result. Therefore the author suggested the model of design dimensionless unit-hydrograph. And the author believes that this model will be much available at none runoff record river site. In the large size watersheds in Korea when the maximum discharge occurs, the effective rainfall is two consequtive stormy days. So the loss in watershed was assutned as 6Omm/2days,and the author proposed 3-hour-daration hydrograph flow distribution percentage. This distribution percentage will be sure to form the hydrograph coordinate.

  • PDF

Rainfall Correction of Radar Image Data and Estimation Runoff of Urban Stream using Vflo (레이더 자료의 강우보정 및 Vflo를 활용한 도심하천의 홍수량 산정)

  • Kang, Bo-Seong;Yang, Sung-Kee;Kim, Yong-Seok
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.411-420
    • /
    • 2017
  • This research aims at comparing the accuracy of flood discharge estimation. For this, we focused on the Oedo watershed of Jeju Island and compared flood discharge by analyzing the values as follows: (1) the concentration of the lumped model (HEC-HMS) and distributed model (Vflo), and (2) the in-situ data using Fixed Surface Image Velocimetry (FSIV). The flood discharge estimation from the HEC-HMS model is slightly larger than the Vflo model results. This result shows that the estimations of the HEC-HMS are larger than the flood discharge data by 4.43 to 36.24% and that of the Vflo are larger by 8.49 to 11%. In terms of the error analysis at the peak discharge occurrence time of each mapping, HEC-HMS is one hour later than the measured data, but Vflo is almost the same as the measured data.

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.

Statistical Characteristics of Pollutants in Sterm Flow (하천오염인자의 통계적 특성)

  • 황임구;윤태훈
    • Water for future
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 1981
  • The auto-and cross-correlation function, power spectrum, coherence function and Markov model are applied to investigate the statistical characteristics of discharge and each factor of water quality and the interrelation-ship between the variation of discharge and water quality factors. The analysis of discharge, dissolved oxygen and electric conductivity, which were only obtainable data at the Indogyo gagining station in the downstream of the Han River, clearly showed that they hace distinct period of 12 months and three different periods of 6, 4 and 3 months weaker than the former. The cross-correlation between the discharge and water quality(DO, COND) is rather weak and the crosscorrelation function has its peak at lag one. It is considered therefrom that the variation of discharge behaves on water quality facotrs with one day's difference. In the examination of linear regression model for the serial generation and predictive measures, discharge series is fit to first and second order Markov model and DO, COND to first order Markov model.

  • PDF

A Numerical Analysis with the FSI Mode on the Characteristics of Flow Field and Discharge Valve Motion in a Rotary Compressor (로터리 압축기의 토출밸브의 미소 거동 및 유동 특성에 대한 FSI(Fluid-Structure Interaction) 기법을 이용한 수치해석)

  • Chae, Hee-Moon;Kim, Chang-Nyung;Park, Sung-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.112-120
    • /
    • 2008
  • This study has been conducted to investigate the characteristics of flow field and discharge valve motion in a rotary compressor. In this study, a transient three-dimensional numerical analysis using FSI(Fluid-Structure Interaction) model has been employed to analyze the interaction between the discharge valve and the refrigerants in the rotary compressor. It has been observed that two peaks have appeared in the displacement of the discharge valve. The maximum displacement of the discharge valve has been found to be located at the second peak. Also, the input pressure of the refrigerants has been compared with the pressures of the muffler passage and the compressor outlet in the rotary compressor. The pressure has decreased along the pathway in the rotary compressor. And the volume flow rates obtained from the current numerical study have been compared with the experiment at data to verify the validity of the present numerical study. This study may supply the fundamental data for the design of rotary compressors.

Particle Swarm Optimization-Based Peak Shaving Scheme Using ESS for Reducing Electricity Tariff (전기요금 절감용 ESS를 활용한 Particle Swarm Optimization 기반 Peak Shaving 제어 방법)

  • Park, Myoung Woo;Kang, Moses;Yun, YongWoon;Hong, Seonri;BAE, KUK YEOL;Baek, Jongbok
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.388-398
    • /
    • 2021
  • This paper proposes a particle swarm optimization (PSO)-based peak shaving scheme using energy storage system (ESS) for electricity tariff reduction. The proposed scheme compares the actual load with the estimated load consumption, calculates the additional output power that the ESS needs to discharge additionally to reduce peak load, and adds the input. In addition, in order to compensate for the additional power, the process of allocating power to the determined point is performed, and an optimization that minimizes the average of the load expected at the active power allocations using PSO so that the allocated value does not affect the peak load. To investigated the performance of the proposed scheme, case study of small and large load prediction errors was conducted by reflecting actual load data and load prediction algorithm. As a result, when the proposed scheme is performed with the ESS charge and discharge control to reduce electricity tariff, even when the load prediction error is large, the peak load is successfully reduced, and the peak load reduction effect of 17.8% and electricity tariff reduction effect of 6.02% is shown.