• Title/Summary/Keyword: Peak Detector

Search Result 323, Processing Time 0.026 seconds

Fabrication and Device Characteristics of Infrared Photodetector Based on InAs/GaSb Strained-Layer Superlattice (InAs/GaSb 응력초격자를 이용한 적외선검출소자의 제작 및 특성 연구)

  • Kim, J.O.;Shin, H.W.;Choe, J.W.;Lee, S.J.;Kim, C.S.;Noh, S.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.108-115
    • /
    • 2009
  • The superlattice infrared photodetector (SLIP) with an active layer of 8/8-ML InAs/GaSb type-II strained-layer superlattice (SLS) of 150 periods was grown by MBE technique, and the proto-type discrete device was defined with an aperture of $200-{\mu}m$ diameter. The contrast profile of the transmission electron microscope (TEM) image and the satellite peak in the x-ray diffraction (XRD) rocking curve show that the SLS active layer keeps abrupt interfaces with a uniform thickness and a periodic strain. The wavelength and the bias-voltage dependences of responsivity (R) and detectivity ($D^*$) measured by a blackbody radiation source give that the cutoff wavelength is ${\sim}5{\mu}m$, and the maximum Rand $D^*$ ($\lambda=3.25{\mu}m$) are ${\sim}10^3mA/W$ (-0.6 V/13 K) and ${\sim}10^9cm.Hz^{1/2}/W$ (0 V/13 K), respectively. The activation energy of 275 meV analyzed from the temperature dependent responsivity is in good agreement with the energy difference between two SLS subblevels of conduction and valence bands (HH1-C) involving in the photoresponse process.

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Replica Correlation-Based Synchronization with Low Complexity and Frequency Offset Immunity

  • Chang, Kapseok;Bang, Seung Chan;Kim, Hoon
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.739-747
    • /
    • 2013
  • This paper investigates the multifarious nature of the long-term evolution (LTE) scheme and that of the modified LTE scheme for symbol timing synchronization (STS). This investigation allows us to propose a new replica correlation-based STS scheme to overcome the inherent weaknesses of the other two schemes. The proposed STS signal combines a gold sequence and a half sine wave in the time domain, whereas conventional STS signals specify either binary sequences or complex sequences in the time domain or in the frequency domain. In the proposed scheme, a sufficient correlation property is realized by the gold sequence, and robustness against the frequency offset (FO) is achieved through the sine wave. Compared to the existing LTE-related schemes, the proposed scheme can better achieve immunity to FO and reduction in detector complexity, as well as a low peak-to-average power ratio and a low detection error rate. Performance evaluations through analysis and simulation are provided in the paper to demonstrate these attributes.

A Study on the Sensor Calibration of Motion Capture System using PSD Sensor to Improve the Accuracy (PSD 센서를 이용한 모션캡쳐센서의 정밀도 향상을 위한 보정에 관한 연구)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.583-585
    • /
    • 2004
  • In this paper we will deal with a calibration method for low cost motion capture system using psd(position sensitive detection) optical sensor. To measure the incident direction of the light from LED emitted marker, the PSD is used the output current ratio on the electrode of PSD is proportional with the incident position of the light focused by lens. In order to defect the direction of the light, the current output is converted into digital voltage value by opamp circuits peak detector and AD converter with the digital value the incident position is measured. Unfortunately, due to the non-linearly problem of the circuit poor position accuracy is shown. To overcome such problems, we compensated the non-linearly by using least-square fitting method. After compensated the non-linearly in the circuit, the system showed more enhanced position accuracy.

  • PDF

Characteristics of Insulation Aging in 4.16kV Motor Stator Windings (4.16kV 전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1381_1382
    • /
    • 2009
  • Nondestructive tests were performed on two 4.16kV motors. Epoxy-mica coupler(80pF) was connected to 4.16 kV motor stator windings. The voltage applied to the stator windings was 2.4 kV, 3.0kV, 3.5kV and 4.16kV, respectively. Digital partial discharge detector(PDD) and turbine generator analyzer(TGA) were used to measure partial discharge(PD) activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of stator windings were indicated the internal discharge. PD patterns are consistent with the result of measurement using PDD and TGA.

  • PDF

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Analysis of 4-Nitrotoluene in Water by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 수질시료 중 4-니트로톨루엔의 분석법 연구)

  • 이희경;권오승;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.45-51
    • /
    • 2000
  • Analytical method of 4-nitrotoluene (4-NT) in water was developed by 9as chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). 4-NT was extracted with diethyl ether. Organic layer was washed with 5 % sodium chloride solution. The influence of solvent and evaporation condition on extraction of 4-NT were examined. The retention time of 4-NT peak was 7.72 min. Coefficient of variation (CV) of 4-NT (ng) within day and day-to-day was ranged from 7.0 to 14.6% and from 7.7 to 20.8%, respectively. Recovery of 4-NT was ranged from 84 to 109%, and detection limit of 4-H was lese than 1 ng/㎖.

  • PDF

AC/DC low current measurement system using the saturable magnetic cores (포화자성체 코어를 이용한 직교류 저전류측정장치)

  • Park, Y.T.;Jang, S.M.;Lee, Y.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.620-622
    • /
    • 2001
  • 자성체 코어의 비선형 특성을 이용하여 DC와 AC 전류를 측정하는 Zero-Flux Current Transformer는 정밀 전류 측정용으로 많이 연구되고 있다. Zero-Flux Current Transformer는 DC 대전류 측정에 합당하며 저 전류 측정에 사용될 경우 소모전류, 안정되고 첨예한 필터 제작, magnetic modulator에 의한 zero point drift, 자화 전류가 비대칭일 때 출력 등과 같은 문제가 해결되어야 한다. 그리고 상용으로 사용하기 위하여 Hand-Held Type으로 제작되어야하며 동작시의 소모전류가 작고 정확도가 우수하여야 한다. 본 연구에서는 자화 전류가 비대칭일 때 출력을 zero로 만들기 위하여 사용하는 필터와 복잡한 회로로 구성된 magnetic modulator 부분을 여러개의 peak detector를 사용하여 AC와 DC를 측정하는 클램프미터를 개발하였으며 그 특성에 대한 내용을 기술하였다.

  • PDF

Segmented Video Coding Using Variable Block-Size Segmentation by Motion Vectors (움직임벡터에 의한 가변블럭영역화를 이용한 영역기반 동영상 부호화)

  • 이기헌;김준식;박래홍;이상욱;최종수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.62-76
    • /
    • 1994
  • In this paper, a segmentation-based coding technique as applied to video sequences is proposed. A proposed method separates an image into contour and texture parts, then the visually-sensitive contour part is represented by chain codes and the visually-insensitive texture part is reconstructed by a representative motion vector of a region and mean of the segmented frame difference. It uses a change detector to find moving areas and adopts variable blocks to represent different motions correctly. For better quality of reconstructed images, the displaced frame difference between the original image and the motion compensated image reconstructed by the representative motion vector is segmented. Computer simulation with several video sequences shows that the proposed method gives better performance than the conventional ones in terms of the peak signal to noise ratio(PSNR) and compression ration.

  • PDF

Primary side control of Flyback converter using sawtooth wave (톱니파를 이용한 플라이백 컨버터의 일차 측 제어)

  • Nam, Sang-Guk;Kim, Ki-Hyun;Kim, Min-Sung;Seo, Kil-Soo;Kim, Nam-Kyun;Song, Han-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.932-933
    • /
    • 2015
  • This paper presents methods to achieve and control accurate output voltage. PSR removed secondary output voltage sensing circuit, therefore standby power loss can be decreased. When sensing the auxiliary winding voltage, sensing must be done at accurate branch which has $V_O$ information. For this reason this paper presents the PSR sensing technique using sawtooth wave and peak detector. Circuit verification carried out with Spectre in Cadence corporation and Manga/Hynix $0.35{\mu}m$ 700V process.

  • PDF