• Title/Summary/Keyword: Peak Detector

Search Result 323, Processing Time 0.03 seconds

Simultaneous Quantitative Determination of Monosaccharides Including Fructose in Hydrolysates of Yogurt and Orange Juice Products by Derivatization of Monosaccharides with p-Aminobenzoic Acid Ethyl Ester Followed by HPLC

  • Ko, Joung-Ho;Huang, Huazi;Kang, Gyoung-Won;Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1533-1538
    • /
    • 2005
  • We have determined the contents of monosaccharides in the hydrolysates of some yogurt and orange juice products by derivatizing monosaccharides with p-aminobenzoic acid ethyl ester (ABEE). The separation of the ABEE-derivatized monosaccharides was efficiently carried out by HPLC using a microcolumn packed with the Alltima $C_{18}$ stationary phase. The concentrations of monosaccharides were determined based on the measured peak area/height counts. ABEE derivatization of fructose and its detection have never been successfully carried out before this work. In this study, two peaks were observed in a fixed ratio for ABEE-fructose, and the ratio was maintained over a wide range of fructose concentration. In order to prove the validity of the above method, we compared the concentrations of glucose, galactose and fructose determined by ABEE derivatization and UVD (ultraviolet detector) chromatography with those determined by RID (refractive index detector) chromatography without derivatization. The determined concentrations of monosaccharides obtained from the two chromatographic methods were found close to each other within acceptable error ranges.

Analysis of Insulation Condition in High Voltage Motor Model Coils (고압전동기 모델 코일의 절연상태 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Byeong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1612-1614
    • /
    • 2003
  • 80pF capacitive couplers were connected to six 6.6kV motor model coil terminals. The voltage applied to the coils were 3.81kv, 4.76 kV and 6.6kV, respectively. These stator coils have various types of artificial insulation defects such as large voids, semi-conductive coating damage and strand insulation fault. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in PD were measured with a conventional digital PD detector. Most of the defect mechanism of large motor stator winding can be associated with PD patterns such as internal and slot discharges. PD patterns coincide with PDD and TGA. These instruments have an input bandwidth of 40-400kHz and 0.1-350MHz. Surge testing detects faults in inter-turn winding of high voltage motor model coils.

  • PDF

Analysis of Melatonin Content from Domestic Edible Plants (국내산 식용식물체의 멜라토닌 함량 분석)

  • Kim, Seok-Joong
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1145-1148
    • /
    • 2002
  • Melatonin, which is a hormone secreted from pineal gland of brain and known to prevent oxidative damages of various tissues, was analyzed in 26 domestic edible plants. For the preparation of melatonin fraction, 50% ethanol extract prepared from lyophilized plant powder was filtered and applied on TLC plate. Melatonin position on TLC developed with acetone was identified by fluorescence light and extracted with methanol. This methanolic fraction was injected into HPLC comprising ODS-A column, fluorescence detector, and mobile phase consisting of a mixture (30 : 70, v/v) of 70% ammonium acetate and methanol at a flow rate of 1.0 mL/min. Melatonin was identified at the retention time of 17 min. Results revealed that celery, leek, broccoli, and cauliflower had higher melatonin contents than others.

A fragmentation database of soyasaponins by liquid chromatography with a photodiode array detector and tandem mass spectrometry

  • Son, Haereon;Mukaiyama, Kyosuke;Omizu, Yohei;Tsukamoto, Chigen
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.172-179
    • /
    • 2021
  • Oleanane-type triterpenoids exist as secondary metabolites in various plants. In particular, soyasaponin, an oleanane-type triterpenoid, is abundant in the hypocotyl of soybean, one of the most widely cultivated crops in the world. Depending on their chemical structure, soyasaponins are categorized as group A saponins or group DDMP (2,3-dihydro-2,5-dihydroxy-6-methyl-4H-pyran-4-one) saponins. The different soyasaponin chemical structures present different health functionalities and taste characteristics. However, conventional phenotype screening of soybean requires a substantial amount of time for functionality of soyasaponins. Therefore, we attempted to use liquid chromatography with a photodiode array detector and tandem mass spectrometry (LC-PDA/MS/MS) for accurately predicting the phenotype and chemical structure of soyasaponins in the hypocotyl of five common soybean natural mutants. In this method, the aglycones (soyasapogenol A [SS-A] and soyasapogenol B [SS-B]) were detected after acid hydrolysis. These results indicated that the base peak and fragmentation differ depending on the chemical structure of soyasaponin with aglycone. Thus, a fragmentation database can help predict the chemical structure of soyasaponins in soyfoods and plants.

Feasibility study on a stabilization method based on full spectrum reallocation for spectra having non-identical momentum features

  • Kilyoung Ko ;Wonku Kim ;Hyunwoong Choi;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2432-2437
    • /
    • 2023
  • Methodology for suppressing or recovering the distorted spectra, which may occur due to mutual non-uniformity and nonlinear response when a multi-detector is simultaneously operated for gamma spectroscopy, is presented with respect to its applicability to stabilization of spectra having the non-identical feature using modified full spectrum reallocation method. The modified full-spectrum reallocation method is extended to provide multiple coefficients that describe the gain drift for multi-division of the spectrum and they were incorporated into an optimization process utilizing a random sampling algorithm. Significant performance improvements were observed with the use of multiple coefficients for solving partial peak dislocation. In this study, our achievements to confirm the stabilization of spectrum having differences in moments and modify the full spectrum reallocation method provide the feasibility of the method and ways to minimize the implication of the non-linear responses normally associated with inherent characteristics of the detector system. We believe that this study will not only simplify the calibration process by using an identical response curve but will also contribute to simplifying data pre-processing for various studies as all spectra can be stabilized with identical channel widths and numbers.

Extraction Methods and HPLC Analysis Conditions of Paeoniflorin in Peony, Paeonia lactiflora Pall. (작약(Paeonia lactiflora Pall.)에서 paeoniflorin 추출방법 및 HPLC 분석조건)

  • ;Kwang-He Kang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.6
    • /
    • pp.542-547
    • /
    • 1994
  • To find out the most reasonable analysis conditions of paeoniflorin, different paeoniflorin extraction methods and various UV detector wavelengths were conducted with paeonia radix of 4-year old Euisung local variety. The most reasonable paeoniflorin extraction time by reflux apparatus was 1hr. and by ultrasonic apparatus was 3hrs. and those methods were completed only once. Concentration of paeoniflorin by reflux apparatuses at 1hr. and 2hrs. of extracting time were higher than those of ultrasonic apparatus, and the differences were highly significant. However, the differences of paeoniflorin concentration at 3hrs. and 4hrs. in two methods were not significant. In comparing paeoniflorin concentration of many lines, ultrasonic extracting apparatus was more simple and effective than the reflux apparatus. Paeoniflorin was more reasonable sensitivity at 240nm, and albiflorin was 254nm by HPLC. When paeoniflorin and albiflorin were analyzed simultaneously, 254nm was more stable than any other wavelength.

  • PDF

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

A Study on the Characteristics of the Multilayer-Type PTC Thermistor for Fire Detection Sensor (화재감지센서 활용을 위한 적층헝 PTC서미스터의 특성에 관한 연구)

  • Chu Soon-Nam;Baek Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.75-80
    • /
    • 2005
  • This dissertation is about the development of PTC(Positive Temperature Coefficient) thermistor by composition method. A multilayer-type PTC samples were fabricated under optimal conditions after setting the experimental composition equation as $(0.90Ba+0.05Sr+0.05Ca)TiO_3+0.01TiO_3+0.01SiO_2+0.0008MnO_2+0.0018Nb_2O_5$ and their testing results were analyzed. The fabrication method of SMD(Surface Mounted Device) multilayer -type sample based on the composition ratio has the advantages in lowering its resistivity at room temperature, considerably, and increasing maximum current level, as needed. Although there is a disadvantage of peak resistivity drop by the multilayer, causing the increasement of thermal capacity. and thereby, increasing the switching delay time, a high applying voltage can increase the peak resistivity and shorten the switching delay time. The voltage-current characteristic showed that the more multilayers increased the initial maximum current and the transition voltage that increased the resistivity abruptly according to the curie point. The element it could be applied with the sensor for the fire detector.

Comparative Study of the Symbol Rate Detection of Unknown Digital Communication Signals (미상 디지털 통신 신호의 심볼율 검출 방식 비교)

  • Joo, Se-Joon;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents and compares several techniques that detect the symbol rate of unknown received signal. Symbol rate is detected from the power spectral density of the circuits such as the delay and multiplier circuit, the square law circuit, and analytic signal, etc. As a result of discrete Fourier transform of the output signals of these circuits, a lot of spectral lines and some peaks appear in frequency domain and the position of first peak is corresponding to the symbol rate. If a spectral line on the frequency that is not located in symbol rate is larger than the first peak, the symbol rate is erroneously detected. Thus, the ratio between the value of first peak and the highest side spectral line is used for the measure of the performance of symbol rate detector. For the MPSK modulation, the analytic signal method shows better performance than the delay and multiplier and square law circuits when the received signal power is lager than -20dB. It is also noted that the delay and multiplier circuit is not able to detect the symbol rate for the QAM modulation.

  • PDF

Studies on the Ginseng Saponins(I) On the Determination of the Ginseng Saponins in Ginseng Tea and Extract (인삼 사포닌에 관한 연구 (I) 인삼 사포닌의 분별 정량에 대하여)

  • 김해중;남성희;;이석건
    • Journal of Ginseng Research
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 1976
  • A determinatien of the saponins in ginseng tea and extract was carried out by using the quantitative TLC autodetector equipped with a hydrogen flame ionization detector. In order to apply to the Quality central of the ginseng tea and extract. the optimum condition and recovery percentage for the quantitative determination of saponins in these products duo studied. The results obtained were as follows: The method was adequate to estimate whether the ginseng extract used for the Products and She raw ginseng extract were the same quality or net. Most of the individual peak area was increased with the concentration of the total saponin. But some of the peak areas were net increased quantitatively in the ease of the sample containing high concentration ginseng extract. To deternine the saponins in ginseng tea correctly high volume low concentration was better than the low volume high concentration. Optimum concentration of ginseng extract in sample to determine the individual saponins was in the range of 0.5∼1.5g. The recovery percentage of the total saponin was 99.5% on the average.

  • PDF