• Title/Summary/Keyword: Pd(100)

Search Result 304, Processing Time 0.026 seconds

The Measurement and Analysis The Electromagnetic Wave by Discharge in Air for Insulation Diagnosis (절연진단을 위한 기중방전에서의 방사전자파 측정과 분석)

  • 이상훈;이현동;이춘하;윤영대;김기채;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.141-144
    • /
    • 1999
  • This paper offer fundamental ones about insulation diagnosis with electromagnetic wave, when discharges occurred. To simulate Partial-Discharge(PD), It is used needle-plane electrode in air. As the voltages applied, measure the electromagnetic wave with monopole antenna and analysis its fundamental characteristics, then, acquired data were operated. The results presented as the form of graph, and the magnitude of charge when occurred PD simultaneously. In conclusion, when the magnitude of charge over 100[pC], the electric field strength changed, and then the magnitude of charge and the electric field strength increased samely.

  • PDF

A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge (부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구)

  • Kim, Ji-Hong;Koo, Ja-Yoon;Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.

Diagnosis of power cable system based on the HFPD detection at on-site (HFPD 검출법을 이용한 지중 케이블 실선로 진단)

  • Lee, J.S.;Kim, C.S.;Lee, D.G.;Kong, C.H.;Seok, K.H.;Lee, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.97-100
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnosis of cable system in the world although Korea just begin. The efficiency of measurement has been reported and proved by many researchers who are engaged in the diagnosis of high power apparatus. LG Cable has investigated the technology of diagnosis for cable system by means of PD measurement for 10 years. In this paper, PD measurement with portable device was performed to evaluate the quality of the 154kV transmission line and the 22.9kV XLPE cable line. Test results are shown that the HFPD detection technology is very attractive for the diagnosis of power cable system by high detection sensitivity at on-site.

  • PDF

Wavelength stabilized high power cw DFB laser module for DWDM transmission (DWDM 송신을 위한 파장안정화 고출력 DFB LD Module)

  • 김종덕;이희태;박경현;송만규;강승구
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.206-209
    • /
    • 2000
  • A wavelength stabilized high power CW DFB LD module was designed and fabricated for use in externally modulated, Dense Wavelength Division Multiplex (DWDM) systems. A simple, compact wavelength monitoring technology using a thin solid Etalon and PD array assembly was developed for a low cost wavelength stabilized DFB LD module. Also, the excellent module have high power characteristic of 13.5 mW in CW 100 mA current injection with high optical coupling coefficient over 43%. r 43%.

  • PDF

Effects of Acupuncture & Qigong Meditation on Nonmotor Symptoms of Parkinson's Disease

  • Kim, Jaejong;Cho, Ki Heang;An, So jung;Cui, Shanqin;Kim, Sun Wook;Suh, Joseph;Lee, Young
    • Journal of Acupuncture Research
    • /
    • v.37 no.4
    • /
    • pp.247-253
    • /
    • 2020
  • Background: Parkinson's disease(PD) affects not only motor symptoms, but also nonmotor symptoms. This study is a clinical trial to determine whether Qigong and acupuncture affect nonmotor symptoms of PD. Methods: A 2-arm parallel and randomized trial was performed with 21 participants who had received either Qigong meditation only [control group (CG)] or acupuncture and Qigong meditation [experimental group (EG)]. The participants' levels of the discomfort in nonmotor symptoms from Parkinson's disease were evaluated by using the Unified Parkinson's Disease Rating Scales (UPDRS 1) and Test of Smell Identification (TSI) before and after 12 treatments at baseline and 1 month after 12 treatments. Results: The both CG and EG showed improvements in the UPDRS 1 score after treatment by 5.6 ± 5.15 (p= 0.003; 74%) and 4.8 ± 3.80 (p = 0.004; 79%), respectively. The both CG and the EG did improvements in the TSI after treatment by 10.3 ± 4.37 (p < 0.001; 84%) and 12.6 ± 1.77 (p = 0.022; 100%), respectively. However, statistical differences were not observed between the CG and the EG using the UPDRS 1 and the TSI scores. Conclusion: The combination of Qigong and acupuncture and Qigong alone was shown to improve the nonmotor symptoms and olfactory function of PD. In the future, large-scale clinical studies on alternative treatment for PD and studies on mechanisms affecting nonmotor symptoms of acupuncture and Qigong are needed.

A Study on Characteristics of the Ni-Pd Alloy Electroplating (Ni-Pd 합금 전해도금의 특성에 관한 연구)

  • Cho, Eun-Sang;Jung, Dae-Gon;Cho, Jin-Ki
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.253-259
    • /
    • 2015
  • The test equipment becomes more important with the development of semiconductor industry. MEMS probe is an important testing component to detect the defects from the generated electric signal when it contacts the metal pad of semiconductor devices. Ni-Pd alloy has been paid attention to as a candidate of MEMS probe material because of its high surface hardness and relatively low resistivity. In this study, electroplated Ni-Pd alloy has been prepared by using ethylene diamine as a complexing agent. Solid solution alloy coating could be formed when concentration of palladium chloride and current density were in the ranges of 1~5 mM and $0.2{\sim}1.5A/dm^2$, respectively. The increase of current density brought about an decrease in palladium content, which made both of lattice parameter and grain size smaller. As a result of grain refinement, high hardness could be obtained. However, surface cracking was observed due to residual stress when the current density was above $1.3A/dm^2$. When effects of heat treatment temperature on hardness and sheet resistance were investigated, the accompanied grain growth decreased both of them. The decrease of hardness remained stable at a temperature of $200^{\circ}C$. The sheet resistance was drastically reduced at $100^{\circ}C$. After that, it was found to become constant.

Selective Catalytic Oxidation of Ammonia over Noble Catalysts Supported on Acidic Fe-ZSM5 Supports (산성 Fe-ZSM5 담체에 담지된 귀금속 촉매를 활용한 암모니아의 선택적 산화반응)

  • Kim, Min-Sung;Lee, Dae-Won;Lee, Kwan-Young
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.89-94
    • /
    • 2012
  • In this study, we investigated the activity of Pd and Pt supported on acidic Fe-ZSM5 supports for selective catalytic oxidation of ammonia ($NH_3$-SCO). Among the catalysts, Pt/Fe-ZSM5 catalyst exhibited superior $NH_3$-SCO activity to Pd/Fe-ZSM5 catalyst. We also tested Pt/Fe-ZSM5 catalysts with different Fe loading using ion-exchange method to prepare Fe-ZSM5 supports, which resulted in the increased catalytic performance with smaller Fe content: $NH_3$ was oxidized completely at low temperature ($250^{\circ}C$). The physicochemical properties of Fe-ZSM5 were investigated to figure out the relationship between the characteristics of the catalysts and the catalytic activity on $NH_3$-SCO by Inductively coupled plasma-atomic emissions spectrometer (ICP-AES), $N_2$ sorption, X-ray diffraction (XRD), temperature programmed desorption of $NH_3$ ($NH_3$-TPD) technique.

Enhancement of Tumor Response by MEK Inhibitor in Murine HCa-I Tumors (C3H/HeJ 마우스 간암에서 MEK 억제제에 의한 방사선 감수성 향상 효과)

  • Kim, Sung-Hee;Seong, Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.207-215
    • /
    • 2003
  • Purpose: Extracellular signal-regulated kinase (ERK), which is part of the mitogen-activated protin kinase cascade, opposes initiation of the apoptotic cell death which is programmed by diverse cytotoxic stimuli. In this regard, the inhibition of ERK may be useful in improving the therapeutic efficacy of established anticancer agents. Materials and Methods: Murine hepatocarcinoma, HCa-I is known to be highly radioresistant with a TCD50 (radiation dose yield in $50\%$ cure) of more than 80 Gy. Various anticancer drugs have been found to enhance the radioresponse of this particular tumor but none were successful. The objective of this study was to explore whether the selective inhibition of MEK could potentiate the antitumor efficacy of radiation in vivo, particularly in the case on radioresistant tumor. C3H/HeJ mice hearing $7.5\~8\;mm$ HCa-I, were treated with PD98059(intratumoral injection of $0.16\;\mug/50\;\mul$). Results: Downregulation on ERK by PD98059 was most prominent 1h after the treatment. In the tumor growth delay assay, the drug was found to Increase the effect of the tumor radioresponse with an enhancement factor (EF) of 1.6 and 1.87. Combined treatment of 25 Gy radiation with PD98059 significantly increased radiation induced apoptosis. The peak apoptotic index (number on apoptotic nuclei in 1000 nuclei X100) was $1.2\%$ in the case of radiation treatment alone, $0.9\%$ in the case of drug treatment alone and $4.9\%,\;5.3\%$ in the combination treatment group. An analysis of apoptosis regulating molecules with Western blotting showed upregulation of p53, p$p21^{WAF1/CIP1}\;and\;Bcl-X_s$ in the combination treatment group as compared to their levels in either the radiation alone or drug alone treatment groups. The level of other molecules such as $Bcl-X_L4, Bax and Bcl-2 were changed to a lesser extent. Conclusion: The selective inhibition of MEK in combination with radiation therapy may have potential benefit in cancer treatment.

Development of Metal Loaded Activated Carbon Fiber for Eliminating Targeted VOCs Originated from Solvent(II) (특정용제 Target 형 활성금속첨착 활성탄소섬유의 개발(II))

  • Choi, Kang-Yong;Kim, Kwang-Su;Kim, Tae-Won;Jun, Min-Kee;Park, Hea-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.472-478
    • /
    • 2013
  • Cu and Cr as a base metal and Pt, Pd as a supportive metal were selected for improving adsorption capacity of activated carbon fiber in eliminating especially targeted VOCs. Preparing variables such as metal loading, loading temperature, loading hours and kinds of loaded metals were changed. Properties measurement was carried out by SEM (scanning electron microscope), XRF (x-ray fluorescence analysis) and EDX (Energy Dispersive X-ray spectrometer) and adsorption capacity evaluation were also performed by gas analyzer. Under this study, the adsorption capacity of complex metal loaded activated carbon fiber was improved positively than that of single metal loaded activated carbon fiber. And we found that the best conditions for metal loading were 5 hours loading time at $100^{\circ}C$ and the adsorption capacity was enhanced almost double compared with other condition based activated carbon fiber. Cu-Cr-Pt-Pd loaded activated carbon fiber showed the best adsorption capacity. Also we confirmed that more than 0.5 second is necessary for adsorbate diffusion and adsorption over activated carbon fiber.

A Study of EPMA Analysis for Nitric Acid Insoluble Alloys (질산불용성 합금의 EPMA분석)

  • Park, Soon-Dal;Park, Yong-Joon;Kim, Jong-Goo;Son, Se-Chul;Joe, Kih-Soo
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.485-494
    • /
    • 1998
  • Ternary and quaternary alloys composed of Mo-Ru-Rh-Pd were prepared and their crystal structure and quantitative chemical compositions were analysed by XRD, WDX, EDX and ICP/AES. The results of X-ray diffraction studies showed that the alloys were crystallized in hexagonal close packing, well known as ${\varepsilon}$-phase with $P6_3/mmc$ of space group. The optimum accelerating voltage for Zr~Cd(40~48) analyzed by EPMA using PET crystal was found to be 15 kV and the linear regression coefficient(R) of atomic number and X-ray intensity was approximately 0.998 without Tc standard specimen. The WDX results of alloys of Mo and Pd by linear regression equations were detected to be 0.1% lower compared to WDX analysis results using standard specimen, while Ru, Rh were detected 3% higher. These alloys were completely dissolved in mixed acid of 12.5 mL HCl and 1 mL $HNO_3$, at $220^{\circ}C$ for 22 hours using autoclave with PTFE vessel. There was no reprecipitating phenomnon when diluted 100 times with 1N-HCl. The results of ICP/AES analysis deviated less than 4% comparing with those of normal WDX analysis.

  • PDF