• Title/Summary/Keyword: Pci

Search Result 499, Processing Time 0.027 seconds

On the Plug-in Estimator and its Asymptotic Distribution Results for Vector-Valued Process Capability Index Cpmk (2차원 벡터 공정능력지수 Cpmk의 추정량과 극한분포 이론에 관한 연구)

  • Cho, Joong-Jae;Park, Byoung-Sun
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.3
    • /
    • pp.377-389
    • /
    • 2011
  • A higher quality level is generally perceived by customers as improved performance by assigning a correspondingly higher satisfaction score. The third generation index $C_{pmk}$ is more powerful than two useful indices $C_p$ and $C_{pk}$ that have been widely used in six sigma industries to assess process performance. In actual manufacturing industries, process capability analysis often entails characterizing or assessing processes or products based on more than one engineering specification or quality characteristic. Since these characteristics are related, it is a risky undertaking to represent the variation of even a univariate characteristic by a single index. Therefore, the desirability of using vector-valued process capability index(PCI) arises quite naturally. In this paper, we consider more powerful vector-valued process capability index $C_{pmk}$ = ($C_{pmkx}$, $C_{pmky}$)$^t$ that consider the univariate process capability index $C_{pmk}$. First, we examine the process capability index $C_{pmk}$ and plug-in estimator $\hat{C}_{pmk}$. In addition, we derive its asymptotic distribution and variance-covariance matrix $V_{pmk}$ for the vector valued process capability index $C_{pmk}$. Under the assumption of bivariate normal distribution, we study asymptotic confidence regions of our vector-valued process capability index $C_{pmk}$ = ($C_{pmkx}$, $C_{pmky}$)$^t$.

Experimental Study on the Shear Strength of Form Tie Connector Linked by Stud Coupler (스터드 커플러로 연결된 폼타이 연결재의 전단내력에 관한 실험 연구)

  • Seo, Soo-Yeon;Kim, Seoung-Soo;Yoon, Yong-Dae;Ha, Gee-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.573-581
    • /
    • 2008
  • In general, conventional sheeting H-pile is often used as a temporary member installed upon construction of outer retaining wall at basement floor. In CBW (composite basement wall), R/C basement wall is combined with H-Pile and resists lateral soil pressure together. This paper presents an experimental results of push out shear test of CBW with stud coupler as shear connectors to combine H-Pile with R/C wall six specimens with different diameter of FT (form tie) and arrangement of shear connectors were tested to evaluate the shear capacity of the composite wall. Test results showed that shear strength increased with diameter of FT. The shear strength of shear connector in CBW could be suitably predicted by using the previous equations codified in the codes. Best correlation, especially, was found when the calculation result by the formula in AISC 360-05 was compared to test one.

Design and Implementation of Buffer Cache for EXT3NS File System (EXT3NS 파일 시스템을 위한 버퍼 캐시의 설계 및 구현)

  • Sohn, Sung-Hoon;Jung, Sung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2202-2211
    • /
    • 2006
  • EXT3NS is a special-purpose file system for large scale multimedia streaming servers. It is built on top of streaming acceleration hardware device called Network-Storage card. The EXT3NS file system significantly improves streaming performance by eliminating memory-to-memory copy operations, i.e. sending video/audio from disk directly to network interface with no main memory buffering. In this paper, we design and implement a buffer cache mechanism, called PMEMCACHE, for EXT3NS file system. We also propose a buffer cache replacement method called ONS for the buffer cache mechanism. The ONS algorithm outperforms other existing buffer replacement algorithms in distributed multimedia streaming environment. In EXT3NS with PMEMCACHE, operation is 33MB/sec and random read operation is 2.4MB/sec. Also, the buffer replacement ONS algorithm shows better performance by 600KB/sec than other buffer cache replacement policies. As a result PMEMCACHE and an ONS can greatly improve the performance of multimedia steaming server which should supportmultiple client requests at the same time.

Experimental Study on Particle Temperature and CO/CO2 Emission Characteristics of Pulverized Coal Combustion Condition According to Coal Types in Blast Furnace (고로 내 미분탄 연소조건에서 탄종에 따른 입자온도와 CO/CO2 배출 특성에 관한 연구)

  • Cho, Young Jae;Kim, Jin Ho;Kim, Ryang Gyun;Kim, Gyu Bo;Jeon, Chung Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.807-815
    • /
    • 2014
  • This study was performed using a laminar flow reactor that could replicate the combustion environment of pulverized coal in a blast furnace. Since a pulverized coal injection system was developed for iron making, the combustion characteristics of pulverized coal have been important in the iron and steel industry. The flame structure, particle temperature, and exhaust gas were investigated for different types of coal. The results of this study demonstrated that the combustion characteristics of coal are influenced by several properties of individual coals. In particular, the CO emission and volatile matter content of individual coals were found to have a strong influence on their combustion characteristics. Thus, this study found the properties of the coals to be significant and focused on the particle temperature and CO and $CO_2$ emissions.

Effects of Cryptosporidium muris (strain MCR) infection on gastric mucosal mast cells in mice (마우스에 있어서 쥐와 포자충 감염이 위점막 비만세포에 미치는 영향)

  • Lee, Jae-Gu;Seol, Chan-Gu;Kim, Hyeon-Cheol
    • Parasites, Hosts and Diseases
    • /
    • v.35 no.4
    • /
    • pp.245-250
    • /
    • 1997
  • The responses of gastric mucosal mast cells (GMMCS) to infection with coccid- ian protozoa, Clptosporinium muris, in mice were examined during primary and challenge infections. Each of three-week-old ICR SPF mice was orally inoculated with a single dose of 2 × 106 oocysts of C. muffs (strain MCR). After oocyst shedding ceased, the mice were orally challenged with a single dose of 2×106 oocysts of the same species. GMMCS reached a peak on days 20-30 postinoculation (Pl) in number, and decreased thereafter. An increase on days 20-30 post-challenge-infection (PCI) was also observed. The mice showed, on the whole, normal profiles of oocyst shedding in droppings. The number of the cells of uninfected control mice remained constant. .Tudging from the above results, it is suggested that mastocytosis correlate with expulsion of C. mans in primary infection and the defense mechanism of challenge infection.

  • PDF

The dependence of the properties of InP grown by chloride vapor phase epitaxy on the growth temperature and on the $PCl_3/H_2$ molar fraction (Chloride VPE법에 의한 InP 에피층 성장시 성장온도 및 $PCl_3/H_2$ 몰비에 따른 특성변화)

  • 김현수;신동석;최인훈
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.61-68
    • /
    • 1997
  • We examined the dependence of the growth of undoped InP epilayer by chloride vapor phase epitaxy on the growth temperature and on the $PCl_3$molar fraction. The growth temperature was varied from $620^{\circ}C$ to $650^{\circ}C$ and the $PCl_3$molar franction from $2.5{\times}10^{-2}$ to $4.5{\times}10^{-2}$. The undoped InP epilayer with hillock free surface was obtained at the growth temperature of $640^{\circ}C$ and at the PCl$_3$molar fraction of $3.0{\times}10^{-2}$. The surface morphology was improved with a decrease of the PCl$_3$molar fraction. The carrier concentration measured by Hall and ECV was less than $1{\times}10^{14}cm^{-3}$. The resistivity of the undoped InP epilayer, measured by using four probe method, showed a high value of <$3.0{\times}10^6{\Omega}\textrm{cm}$.

  • PDF

Screening of Biologically Active Compounds from Weeds I (잡초(雜草)에 함유(含有)된 생리활성물질(生理活性物質) 탐색(探索) I)

  • Kim, C.J.;Kang, B.H.;Lee, I.K.;Ryoo, I.J.;Park, D.J.;Lee, K.H.;Lee, H.S.;Yoo, I.D.
    • Korean Journal of Weed Science
    • /
    • v.14 no.1
    • /
    • pp.16-22
    • /
    • 1994
  • Ninty three species of domestic weeds were collected and screened for antimicrobial, antitumor, antioxidant and herbicidal activities. Among them, few showed antifungal activities. Cuscuta japonica showed inhibitory activity against Alternaria mali, Ambrosia artemisiifolia and Geranium sibiricum against Phytophthora capsici, Aster yomema and Aster pilosus against Phytophthora parasitica. Ambrosia artemisiifolia, Artemisia princeps, Artemisia capillaris, Ludwigia prostrata, Chrysanthemum zawadskii, Bidens frondosa, and Geranium sibiricum showed broad antibacterial activities. Carex chordorhiza, Artemisia capillaris, Persicaria nodosa, Senecio koreanus, Pariicum bisulcatum, Geranium sibiricum showed antiblebbing activity on human chronic leukemia K562 cell, among them, Persicaria nodosa was the strongist. Angelica decursiva, Equisetum arvense, Cimicifuga heracleifolia, Persicaria nodosa, Geranium sibiricum, Oenothera odorata, Cyperus sanguinolentus showed antioxidant activities. Ludwigia prostrata and Peucedanum terebinthaceum showed strong herbicidal activities.

  • PDF

Fabrication, Estimation and Trypsin Digestion Experiment of the Thermally Isolated Micro Teactor for Bio-chemical Reaction

  • Sim, Tae-Seok;Kim, Dae-Weon;Kim, Eun-Mi;Joo, Hwang-Soo;Lee, Kook-Nyung;Kim, Byung-Gee;Kim, Yong-Hyup;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.3
    • /
    • pp.149-158
    • /
    • 2005
  • This paper describes design, fabrication, and application of the silicon based temperature controllable micro reactor. In order to achieve fast temperature variation and low energy consumption, reaction chamber of the micro reactor was thermally isolated by etching the highly conductive silicon around the reaction chamber. Compared with the model not having thermally isolated structure, the thermally isolated micro reactor showed enhanced thermal performances such as fast temperature variation and low energy consumption. The performance enhancements of the micro reactor due to etched holes were verified by thermal experiment and numerical analysis. Regarding to 42 percents reduction of the thermal mass achieved by the etched holes, approximately 4 times faster thermal variation and 5 times smaller energy consumption were acquired. The total size of the fabricated micro reactor was $37{\times}30{\times}1mm^{3}$. Microchannel and reaction chamber were formed on the silicon substrate. The openings of channel and chamber were covered by the glass substrate. The Pt electrodes for heater and sensor are fabricated on the backside of silicon substrate below the reaction chamber. The dimension of channel cross section was $200{\times}100{\mu}m^{2}$. The volume of reaction chamber was $4{\mu}l$. The temperature of the micro reactor was controlled and measured simultaneously with NI DAQ PCI-MIO-16E-l board and LabVIEW program. Finally, the fabricated micro reactor and the temperature control system were applied to the thermal denaturation and the trypsin digestion of protein. BSA(bovine serum albumin) was chosen for the test sample. It was successfully shown that BSA was successfully denatured at $75^{\circ}C$ for 1 min and digested by trypsin at $37^{\circ}C$ for 10 min.

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.