• Title/Summary/Keyword: PbI2

Search Result 514, Processing Time 0.031 seconds

A Study on the Application of PbI2 Dosimetry for QA in the Electron Beam Therapy (전자선 치료의 선량 측정 QA를 위한 PbI2 선량계 적용 연구)

  • Yang, Seungwoo;Han, Moojae;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.517-522
    • /
    • 2020
  • Electron beam have many factors that affect dose distribution, so even if identical settings are used, they should be identified and used for radiation treatment, and the effects on the structures in the body are sensitive, making it difficult to investigate uniform dose distribution on tumors. In this study, a dosimeter was produced using PbI2 which is a photoelectric material, and electrical characteristics were analyzed for 6, 9, and 12 MeV electronics in linear accelerators. The reproducibility test results showed that RSD were 1.1215%, 1.0160%, and 0.05137% respectively at 6, 9, and 12 MeV energies, indicating that the output signals were stable. The linearity evaluation results showed that the R2 values of the reliability indicator for straight line trend lines were 0.9999, 0.9999, and 0.9994, respectively, at 6, 9, and 12 MeV, to confirm that the output signal was proportional to PbI2 as dose increased. The PbI2 dosimeter in this study is judged to be highly applicable to electromagnet measurement and is thought to be able to be used as a basic study of electron detector through photoelectric material.

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • Choe, Chi-Won;Gang, Sang-Sik;Jo, Seong-Ho;Gwon, Cheol;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

X선 영상 검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상에 관한 연구

  • Gwon, Cheol;Choe, Chi-Won;Son, Dae-Ung;Jo, Seong-Ho;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.345-345
    • /
    • 2007
  • 본 연구는 x선 영상검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상을 위한 연구로서, $HgI_2$기반의 다양한 물질을 이용하여 다층구조 방식으로 제작된 필름의 누설전류 특성평가 및 제작된 다층구조의 상부전극물질의 변화에 따른 누설전류 특성을 평가하였다. $HgI_2$기반 다층구조의 제작 물질은 Parylene, $PbI_2$, a-Se을 사용하여 시편(parylene/ITO, ITO/$HgI_2/PbI_2$/ITO, ITO/$HgI_2$/a-Se/ITO)을 제작하였으며, 필름 제작공정은 Screen print, PVD공정으로 다층구조 필름을 제작하였다. 또 한, 다층구조로 제작된 필름에 상부 전극물질은 Au, In, ITO를 사용하여 누설전류의 특성을 평가하였다. 측정 장치로 DC Power Supply(556H. EG&G : 50~200V), X 선 발생장치(Toshiba KXO-50N), 차폐체 (Al 및 Cu), Oscilloscope (LeCroy, LC334AM, USA), Electrometer (Keithley, 6517), Ion chamber 2060 (Radical Co.)을 이용하여, 제작된 $HgI_2$기반 다층구조 sample의 누설전류 특성을 실험하였다. 이 결과로 다층구조에 제작된 물질 및 상부전극에 따른 누설전류의 특성을 평가하였다.

  • PDF

The Monohydrogen Arsenate-sensing Electrodes (Monohydrogen Arsenate 감응 전극)

  • Gwon-Shik Ihn;Il-Bae Park
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.162-167
    • /
    • 1987
  • Four component $Ag_2S$-PbS-$PbHAsO_4-Cu_2S$ and three component $Ag_2S$-PbS-$PbHAsO_4$ electrodes have been prepared and evaluated for the direct measurement of monohydrogen arsenate. The 3.0 : 0.5 : 1.0 : 0.25 (mole ratio, $Ag_2S$:PbS:$PbHAsO_4:Cu_2S$) composition is superior in terms of potentiometric response, stability, rapidity of response and reproducibility. Testing was done over the concentration range $10^{-1}$~$10^{-4}M\;HA_SO_4^{2-}$in 0.1F NH4Ac-NH4OH buffer solution at pH 8.50 with constant ionic strength. Interfering ions were $CN^-,\;I^-,\;S^{-2}$ and $Cl^-$.

  • PDF

Characterization of Plasmodium berghei Homologues of T-cell Immunomodulatory Protein as a New Potential Candidate for Protecting against Experimental Cerebral Malaria

  • Cui, Ai;Li, Yucen;Zhou, Xia;Wang, Lin;Luo, Enjie
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.2
    • /
    • pp.101-115
    • /
    • 2019
  • The pathogenesis of cerebral malaria is biologically complex and involves multi-factorial mechanisms such as microvascular congestion, immunopathology by the pro-inflammatory cytokine and endothelial dysfunction. Recent data have suggested that a pleiotropic T-cell immunomodulatory protein (TIP) could effectively mediate inflammatory cytokines of mammalian immune response against acute graft-versus-host disease in animal models. In this study, we identified a conserved homologue of TIP in Plasmodium berghei (PbTIP) as a membrane protein in Plasmodium asexual stage. Compared with PBS control group, the pathology of experimental cerebral malaria (ECM) in rPbTIP intravenous injection (i.v.) group was alleviated by the downregulation of pro-inflammatory responses, and rPbTIP i.v. group elicited an expansion of regulatory T-cell response. Therefore, rPbTIP i.v. group displayed less severe brain pathology and feverish mice in rPbTIP i.v. group died from ECM. This study suggested that PbTIP may be a novel promising target to alleviate the severity of ECM.

Optimization of Bismuth-Based Inorganic Thin Films for Eco-Friend, Pb-Free Perovskite Solar Cells (친환경 Pb-Free 페로브스카이트 태양전지를 위한 비스무스 기반의 무기 박막 최적화 연구)

  • Seo, Ye Jin;Kang, Dong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.117-121
    • /
    • 2018
  • Perovskite solar cells have received increasing attention in recent years because of their outstanding power conversion efficiency (exceeding 22%). However, they typically contain toxic Pb, which is a limiting factor for industrialization. We focused on preparing Pb-free perovskite films of Ag-Bi-I trivalent compounds. Perovskite thin films with improved optical properties were obtained by applying an anti-solvent (toluene) washing technique during the spin coating of perovskites. In addition, the surface condition of the perovskite film was optimized using a multi-step thermal annealing treatment. Using the optimized process parameters, $AgBi_2I_7$ perovskite films with good absorption and improved planar surface topography (root mean square roughness decreased from 80 to 26 nm) were obtained. This study is expected to open up new possibilities for the development of high performance $AgBi_2I_7$ perovskite solar cells for applications in Pb-free energy conversion devices.

Petrogenesis of Mesozoic granites at Garorim Bay, South Korea: evidence for an exotic block within the southwestern Gyeonggi massif?

  • Kim, Ji In;Choi, Sung Hi;Yi, Keewook
    • Geosciences Journal
    • /
    • v.23 no.1
    • /
    • pp.1-20
    • /
    • 2019
  • We present data from the Mesozoic Keumkang, Palbong, and Baekhwa granites in Garorim Bay, in the southwestern part of the Gyeonggi massif, South Korea. Using major and trace element concentrations, Sr-Nd-Pb isotopic compositions, and sensitive high-resolution ion microprobe (SHRIMP) zircon U-Pb ages, we aim to constrain the petrogenesis of the granites and explain their origin within a broader regional geological context. SHRIMP U-Pb zircon ages of $232.8{\pm}3.2$, $175.9{\pm}1.2$, and $176.8{\pm}9.8$ Ma were obtained from the Keumkang, Palbong and Baekhwa granites, respectively. The Late Triassic Keumkang granites belong to the shoshonite series and show an overall enrichment in large ion lithophile elements (LILE), a depletion in high field strength elements (HFSE) relative to primitive mantle, compared with neighboring elements in the primitive mantle-normalized incompatible trace element diagram with notable high Ba and Sr contents, and negligible Eu anomalies. The Keumkang granites are typified by highly radiogenic Sr and unradiogenic Nd and Pb isotopic compositions: $(^{87}Sr/^{86}Sr)_i=0.70931-0.70959$, $(^{143}Nd/^{144}Nd)_i=0.511472-0.511484$ [$({\varepsilon}_{Nd})_i=-17.0$ to -16.7], and $(^{206}Pb/^{204}Pb)=17.26-17.27$. The Middle Jurassic Palbong and Baekhwa granites belong to the medium- to high-K calc-alkaline series, and show LILE enrichment and HFSE depletion similar to the Keumkang granites, but exhibit significant negative anomalies in Ba, Sr, and Eu. Furthermore, they have elevated Y and Yb contents at any given $SiO_2$ content compared with other Jurassic granitoids from the Gyeonggi massif. The Palbong and Baekhwa granites have slightly less radiogenic Sr and more radiogenic Nd and Pb isotopic compositions [$(^{87}Sr/^{86}Sr)_i=0.70396-0.70908$, $(^{143}Nd/^{144}Nd)_i=0.511622-0.511660$, $({\varepsilon}_{Nd})_i=-15.4$ to -14.7, $(^{206}Pb/^{204}Pb)=17.56-17.76$] relative to the Keumkang granites. The Keumkang granites are considered to have formed in a post-collisional environment following the Permo-Triassic Songrim orogeny that records continent-continent collision between the North and South China blocks, and may have formed by fractional crystallization of metasomatized lithospheric mantle-derived mafic melts. The Palbong and Baekhwa granites may have been produced from a gabbroic assemblage at pressures of less than ~15 kbar, associated with subduction of the paleo-Pacific (Izanagi) plate at the Eurasian continental margin. Elevated ${\varepsilon}_{Nd}(t)$ values in the granitoids from the southwestern part of the Gyeonggi massif relative to those of the central and northern parts, together with the comparatively shallow depth of origin, imply the presence of an exotic block in the Korean lithosphere.

Extraction of Cd and Pb from Soil by Anionic Surfactant and Ligand NaI (NaI 리간드화 계면활성제에 의한 토양내 Cd과 Pb 추출 연구)

  • Heo, Jung-Hyun;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.5
    • /
    • pp.74-80
    • /
    • 2008
  • Heavy metals, Cd and Pb, in soil were extracted by using anionic surfactants such as AOS (alpha olefin sulfonate), SDS (sodium dodecyl sulfate), and LAS (linear alkyl benzene sulfonic acid). Metal extractability from soil was affected by the carbon number and solution pH of surfactants. LAS showed higher metal extractability due to the acidic solution condition. Although SDS has a fewer carbon number than AOS, it would produce smaller micelles and resulted in more efficient extraction of metals by increased soil contact. Cd extractability of surfactant was twice enhanced by adding NaI as a ligand. However, Pb extractability of surfactant was sometimes reduced by adding NaI. Those ligand effects were dependent on solubility of metal-ligand. The column experiment also showed that SDS having smaller micelles resulted in higher metal extractability than AOS.

A Study on the Feasibility of Lead(II) Iodide and Gd2O2S:Tb Overlapping Sensors in Gamma Source Conditions using FLUKA Simulation (FLUKA 전산 모사를 통한 감마선원 조건에서의 요오드화납(II)과 Gd2O2S:Tb가 결합된 센서의 적용가능성 연구)

  • Yang, Seung-Woo;Park, Yoon-Hee;Park, Ji-Koon;Heo, Ye-Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.381-386
    • /
    • 2022
  • Non-Destruction Test (NDT) is a method to check internal defects without destroying the product. Among them, radiographic testing (RT) uses high-energy radiation, so it is very important to prevent radiation exposure of workers. Therefore, in this study, in this study, a radiation sensor structure that improves radiation detection performance compared to the existing PbI2 and can immediately detect accidents in RT was presented. For evaluation, the conversion efficiency was analyzed in the gamma ray source through FLUKA simulation. PbI2 with overlapping Gd2O2S:Tb presented in this study showed a higher radiation sensitivity from 1.22 to 3.22 times than that of non-overlapping PbI2. This indicates that the presented sensor is suitable for use as a radiation sensor for source detection in RT.

상부 Au 전극 면적 Size에 따른 PbI2 필름의 전기적 특성 평가

  • Myeong, Ju-Yeon;Park, Jeong-Eun;Kim, Dae-Guk;Kim, Gyo-Tae;Jo, Gyu-Seok;O, Gyeong-Min;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.374-374
    • /
    • 2014
  • 의료용 X-ray는 과거 analog 방식과, 연구가 진행 중이며 현재 많이 사용되고 있는 digital 방식으로 나누어진다. 최근, 광도전체와 형광체 기반의 flat panel X-ray detector의 발전에 따른 상용화가 이루어지고 있으며, 많은 발전 가능성이 제기되고 있다. flat panel X-ray detector 검출방식은 direct method (직접 방식)와 indirect method (간접 방식)로 나누어진다. 본 연구는 일반적으로 상용화 되어있는 amorphous seleinum (비정질 셀레늄)의 큰 일함수에 의한 저 해상력이라는 단점을 보완하기 위해, 작은 일함수를 가지는 물질을 사용하여, 영상을 얻을 시에 높은 해상력으로 표현할 수 있도록 하고, 원자번호가 높은 물질을 사용하여 X-ray 흡수율을 높일 수 있도록 기존 direct method에 많이 사용되고 있는 amorphous seleinum 기반 digital X-ray detector가 아닌, 이러한 장점을 충족시킬 수 있는 PbI2 물질 층을 사용하여 시편을 제작 하였다. PbI2를 같은 두께로 올린 후, 물질 층 상부에 Au 전극 면적을 다른 size로 제작한 시편으로 X-ray에 노출 시켰다. 이는 상부 전극 size 차이에 따른 신호 차이를 측정하여 전기적 특성을 평가하기 위한 것이다. 전도성을 띠고 있는 ITO (Indium - Tin - Oxide) glass를 이용하여 screen printing 방법으로 제작하였다. PbI2층을 약 160~180 um두께, $3cm{\times}3cm$ size로 5개 제작하였으며, 상부 전극으로는 Au를 진공 증착 시켰다. 상부 전극 size는 각각 시편 5개에 $0.5cm{\times}0.5cm$, $1cm{\times}1cm$, $1.5cm{\times}1.5cm$, $2cm{\times}2cm$, $2.5cm{\times}2.5cm$로 PbI2 물질 층 중앙에 증착 시켰다. 이러한 설정으로 X-ray 노출 시 관찰할 수 있는 PbI2의 전기적인 특성을 평가할 수 있었다. 관전압을 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp, 140 kVp로 설정하고, 관전류는 100 mA로 설정하였으며, Dark current, Sensitivity를 측정하였다. Dark current와 Sensitivity를 측정한 뒤, 그 값을 이용하여 SNR (신호 대 잡음 비)값을 구해보았다.실험 결과 단위면적당 signal과 SNR을 분석할 수 있었다. 80 kVp로 기준을 잡고 결과 값을 보면 $0.5cm{\times}0.5cm$ 시편에서 2.92 nC/cm2, $2.5cm{\times}2.5cm$ 시편에서 0.84 nC/cm2로 상부 전극 크기가 작을수록 더 좋은 신호를 측정할 수 있었다. 똑같은 기준에서 SNR을 계산 해 보았을 때, $0.5cm{\times}0.5cm$ 시편에서 6.46, $2.5cm{\times}2.5cm$ 시편에서 1.91로 SNR역시 상부 전극 크기가 작을수록 더 큰 값을 확인할 수 있었다. 이러한 결과는 edge-effect의 영향으로 인해 나온 결과라고 할 수 있다. 이러한 실험 결과, detector 제작 시, 같은 물질을 사용하여 더 높은 효율을 내기 위해서는 큰 size의 상부 전극 보다는 작은 size의 상부 전극을 증착 시키는 것이 전기적 특성을 더욱 효율적으로 평가할 수 있을 것이라고 사료된다.

  • PDF