• Title/Summary/Keyword: Paved Area

검색결과 75건 처리시간 0.031초

Characteristics of Wash-off Metal Pollutants from Highway Toll-Gate Area (고속도로 영업소지역의 강우유출수내 중금속 유출 특성)

  • Lee, Soyoung;Lee, Eunju;Kim, Chulmin;Son, Hyungun;Maniquiz, Marla C.;Son, Youngkyu;Kang, Heeman;Kim, Jeehyeong;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • 제23권6호
    • /
    • pp.945-950
    • /
    • 2007
  • The stormwater runoff from paved area are highly polluted because of particulate materials as well as metals from various vehicular activities. The Division of Road Maintenance in Ministry of Construction and Transportation was recently developed the Guidelines of Environment-kindly Road Maintenance. It is actually requiring the BMP construction to control the nonpoint source pollution as based on the TMDL program. This research is carried out in order to define the characteristics of stormwater runoff from the toll-gate of highways since 2006, which is actually one of the main pollutant sources of paved areas. This monitoring is the first phase work for establishing the treatment facilities in the toll-gates. The one of the main characteristics from toll-gate runoff is the first flush phenomenon containing lots of sediments and metal compounds at the beginning of a storm event. Usually it is used to determine the size of treatment facilities and to calculate the reduced pollutant mass in the facility. The research results shows that the mean EMC vaules for heavy metals are determined to $274.3{\mu}g/L$ for Cd, $1,273.4{\mu}g/L$ for Cr, $1,822.0{\mu}g/L$ for Cu, $6,504.9{\mu}g/L$ for Fe, $14,930.3{\mu}g/L$ for Pb, and $714.1{\mu}g/L$ for Zn. Also the metal mass loadings from the toll-gates are calculated using EMC, watershed area and storm duration.

Air Temperature Variation by Effect of Green Space Distribution (녹지분포에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • 제5권2호
    • /
    • pp.47-52
    • /
    • 2002
  • In this study, in order to find out relationship of green space distribution and lower air temperature effect, observed air temperature distribution in and out green space in the cloudy. On basis of the result, we are analyzed relationship of air temperature distribution in and out green space, of green space distribution and air temperature of, lower air temperature effect and the urban in between the green space by using regression analysis. According to the result, the higher temperature zone formed around urban, and the lower temperature zone was similar to shape of green space. In case of the green space, higher temperature zone is formed around paved surface and barren ground, lower temperature zone is done forest and water area. To compare air temperature of windward and leeward around green space, the windward formed the lower temperature zone and although the wind direction is not the leeward to the green space, air temperature formed lower temperature zone to the urban in between the green space.

The effects of Operating Backup Dispatch Center as a System Dispatch Center (후비급전소를 계통급전소로 운영함에 따른 효과)

  • Lee, Ik-Jong;Cho, Burm-Sup;Kim, Yong-Soo;Kim, Hyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.307-308
    • /
    • 2008
  • This paper presents the effects of operating Backup Dispatch Center as a System Dispatch Center(SDC). SDC operates the 154kV transmission lines outside of Seoul metropolitan area, and acts as the backup dispatch center in case of central dispatch center's failure. With SDC, it became possible not only to divide operation of Korean transmission lines to separate control centers according to voltage and region, but to clear faults faster and more accurately. It has paved the way to improve power system reliability and advance the power system operation in general.

  • PDF

EVALUATION OF GROUNDWATER-STREAM INTERACTION IN AN URBAN STREAM, CHEONGGYECHEON, KOREA

  • Hyun Yun-Jung;Kim Yoon-Young;Lee Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.328-331
    • /
    • 2005
  • Cheonggyecheon, covered and Paved with concretes for about more than 50 years, is a losing stream crossing over the downtown of Seoul, Korea. Due to several environmental and economic Problems about the Cheonggyecheon area, the Cheonggyecheon restoration construction has started in 2003. In restoration of Cheonggyecheon, hydraulic barriers are to be installed so as to reduce stream depletion rates for maintaining the stream flow with supplying a certain amount of water. This study evaluates the groundwater-stream interaction by analyzing stream depletion rates of Cheonggyecheon. Results show that significant stream depletion occurs at the up-midstream where the Seoul subway lines are concentrated. Simulation results demonstrate that both horizontal and vertical hydraulic barriers impeding groundwater flow into subway lines are more efficient than a horizontal barrier only for stream depletion rate reduction.

  • PDF

Comparison of Thermal Environment and Biotope Area Rate according to Land Cover Types of Outside Space of School located in Chung-ju (충주시 학교외부공간 피복유형에 따른 온열환경 및 생태면적률 비교)

  • Ju, Jin-Hee;Ban, Jong-Heu;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • 제19권9호
    • /
    • pp.1103-1108
    • /
    • 2010
  • This study was conducted to be used as basic data of environmental friendly construction planning by comparing and analyzing thermal environment, find particles and biotope area rate according to land cover types of outside space of schools located in Chung-ju. When meteorological factors were analyzed according to land cover types, for temperature planting area and paved area showed low-and high-temperature ranges, respectively, and relative humidity was negatively related with temperature as low-and high-temperature ranges corresponded to high-and low-humidity ranges, respectively. For Wet Bulb Globe Temperature Index (WBGT) by land cover types, it was observed to be artificial grass> bare land> natural grass. Find particles were different according to land cover types of playground with being bare land> artificial grass> natural grass in the order. Bare land playground, where there were artificial factors and no absorption of fine particles through stomata of leaves as a function of natural circulation, recorded the highest level of $39.8\;{\mu}g/m^3$ and the level was relatively higher compared to the levels by season in Chung-ju. Biotope area rate showed the order of M elementary school> K elementary school> C commercial high school. That was considered to be caused by the difference of land cover type of school playground accounting for a large part of a school.

The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index) (도심 녹음수의 체감온도지수(WBGT) 조절효과)

  • 주민진;이춘석;류남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제32권3호
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)

Ecosystem Structure and Improvement of Naturalness in Urban Area -In the Case of Kangseo-gu in Seoul- (도시생태계 현황파악 및 자연성 증진 방안 -서울시 강서구를 사례로-)

  • 이수동;이경재
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제32권3호
    • /
    • pp.1-17
    • /
    • 2004
  • The focus of this study is the promotion of green area volumes and their naturalness, water circulation system, decline of entropy, creation of biological habitats and linkage of separated urban green space. Re-presentative urban biotope survey sites were categorized as urban biotope, semi-natural biotope, and natural forest. In the urban biotope, a residential biotope was constructed near the Han river and in mountain areas. The green-area ratio at the housing complex was about 25%. GVZ(Grunvolumenzahl) was 0.35m$^3$/m$^2$ at the 5∼10-story housing complex, and 1.53m$^3$/m$^2$ over the 11-story. As for the green-area structure of the housing complex, canopy layer, understory layer, and shrub layer were not differentiated and the green-area volume was not high enough. The green-area ratio of school areas as a public area biotope was 5∼20%. GVZ was 1.12m$^3$/m$^2$ at Myungduk High School, and 1.78m$^3$/m$^2$ at Jeonggok Elementary School. In order to convert the urban biotope into an ecological area, green areas around the buildings should be connected to urban buffer green areas, and multi-layer structures should be established with natural plant species. In the semi-natural biotope, neighbor parks were created park in the vicinity of the natural forests. GVZ was 0.28m$^3$/m$^2$, and plantation was established with single layer structure and was definitely insufficient for the area. The urban buffer green areas have been established in strip corridors with the width of 20∼123m. In those areas, GVZ was 0.16∼0.27m$^3$/m$^2$ and had a deficient canopy layer, understory layer, and shrub layer. Soil conditions were not favorable for tree growth. In the natural biotope, GVZ of the plantation was 1.03∼1.5m$^3$/m$^2$ but the high crown closure of this area reduces the chance of species change and succession. GVZ of natural forest was 2.53∼2.57m$^3$/m$^2$. It is desirable to plant diverse plants and the natural forest should be succeeded by broad-leaf deciduous tree species. To improve the value of biotope at Kangseo-Gu, building height needs to be limited to reduce the environmental deterioration in the city. In order to maintain the water circulation system, water-permeable material is recommened when the urban surface areas are paved. The establishment of a water circulation system will improve ground water levels, soil moisture, water quality, and habitats. In order to improve biological diversity, it is desirable to have multi-layer structures in urban green areas with native species.

Controlling Noxious Animal Odours : An Imperative at the Rural-Urban Interface - Review -

  • Jiang, J.K.;Sands, J.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권4호
    • /
    • pp.633-641
    • /
    • 1999
  • Reaction by neighbours to odours is increasingly affecting operations of existing animal farming operations and may adversely constrain the further development of the animal production industry in some parts of Australia. It is critical that the scale of such odour impact on the rural-urban interface be estimated to provide useful information both for environmental protection and animal farming operations. Furthermore, the information can be used to modify odour reduction strategies as economic conditions change. The Centre for Water and Waste Technology at The University of New South Wales has developed a comprehensive set of odour control techniques in the course of its research and development effort over the past eight years. Techniques have been developed for odour sampling at point, area and volume sources, monitoring environmental parameters such as ventilation rate, shed temperature, shed humidity, litter water content and ambient meteorological condition, olfactometry and odour dispersion modelling. The work has paved the way for the establishment of odour reduction strategies based on best environmental management practice and advanced odour abatement technologies.

Washoff Characteristics and Correlation of Nonpoint pollutants in a Bridge Storm Runoff (교량 강우유출수내 비점오염물질의 유출특성 및 상관성)

  • Wee, Seung-Kyung;Kim, Lee-Hyung;Jung, Yong-Jun;Gil, Kyung-Ikt
    • Journal of Korean Society on Water Environment
    • /
    • 제24권3호
    • /
    • pp.378-382
    • /
    • 2008
  • During the dry periods, many types of pollutants are being accumulated on the paved surface by vehicle activities and the accumulated various pollutants are inflowing into the near watershed areas for the rainfall periods. Particularly, bridges are the centralized region to be the surface runoff of the stromwater due to the high ratio of the impermeable area. Also, the metals, toxic chemicals and sediments originated from bridges could be strongly influenced to the watershed areas during the runoff. Therefore, the present study is achieved to provide washoff characteristics and correlation from the bridge during rainfall periods. The result shows that the EMC ranges for 95% confidence intervals in a bridge land use are 10.12~128.09 mg/L for TSS, 6.07~21.15 mg/L for BOD, 2.10~6.70 mg/L for TN and 0.06~0.85 mg/L for TP.

The Influence of Land Cover and Zoning on the Urban Heat Island in Cheongju (도시내 용도지역의 토지피복형태가 열섬현상에 미치는 영향)

  • Cho, Sung-Moh;Yoon, Yong-Han;Ryu, Eul-Ryul;Park, Bong-Ju;Kim, Won-Tae
    • Journal of Environmental Science International
    • /
    • 제18권2호
    • /
    • pp.169-176
    • /
    • 2009
  • The present study observed temperature in order to identify factors affecting temperature by zoning and to measure the intensity of their impact on temperature. The empirical results of analyzing observed data are as follows. In order to make up for multicollinearity, a problem in multiple regression analysis, and to give more specific explanations, this study conducted factor analysis and obtained desirable data with adequacy and statistical significance. In the correlation matrix, factors decreasing temperature were planted areas, water surfaces and grasslands, and those increasing temperature were bare grounds, paved areas, and building area. According to land cover patterns, commercial areas had the highest temperature lowering effect. Through the rotated component matrix, we found that factors are grouped into those decreasing temperature, those increasing temperature, and those with low significance in increasing or decreasing temperature. In order to solve the problem of multicollinearity in multiple regression analysis, we performed factor analysis between the land use patterns and temperature and confirmed the usability of factor analysis as a new analysis method in urban heat island.