• Title/Summary/Keyword: Pattern damage

Search Result 783, Processing Time 0.023 seconds

Evaluation of Static Behaviour of Orthotropic Steel Deck Considering the Loading Patterns (하중재하 패턴을 고려한 강바닥판의 정적거동 평가)

  • Kim, Seok Tae;Huh, Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.98-106
    • /
    • 2011
  • The deck of steel box girder bridges is composed of deck plate, longitudinal rib, and transverse ribs. The orthotropic steel decks have high possibility to fatigue damage due to numbers of welded connection part, the heavy contact loadings, and the increase of repeated loadings. Generally, the local stress by the repeated loadings of heavy vehicles causes the orthotropic steel deck bridge to fatigue cracks. The increase of traffic volume and heavy vehicle loadings are promoted the possibility of fatigue cracks. Thus, it is important to exactly evaluate the structural behavior of bridge considering the contact loading area of heavy vehicles and real load patterns of heavy trucks which have effects on the bridge. This study estimated the effect of contact area of design loads and real traffic vehicles through the finite element analysis considering the real loading conditions. The finite element analysis carried out 4 cases of loading patterns in the orthotropic steel deck bridge. Also, analysis estimated the influence of contact area of real truck loadings by the existence of diaphragm plate. The result of finite element analysis indicated that single tire loadings of real trucks occurred higher local stress than one of design loadings, and especially the deck plate got the most influence by the single tire loading. It was found that the diaphragm attachment at joint part of longitudinal ribs and transverse ribs had no effects on the improvement of structural performance against fatigue resistance in elastic analysis.

Regional snows scenario for the support systems Analysis (지역별 제설 시나리오 응원체계 구축연구)

  • Kim, Heejae;Oak, Youngsuk;Kim, Geunyoung
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.163-172
    • /
    • 2017
  • Because of abnormal weather, a heavy snow on the Northern latitudes occurs frequently. This has resulted in significant damage and recovery costs. In korea, it has been declared a special disaster area due to heavy snowfall in Gangneung and Pohang 2004, 2005 and 2011, so there was a revision of action instruction for the road snow removal. Although, in our current system, snow removing methodology, regional equipment holdings, and snow responsible interval, respectively, has been classified by the National Highway, near cities and provinces support system not yet prepared. Only, if snow removing is not possible within the region itself, which contained the contents of "support and assistance to military or nearby offices requests". In this thesis, we studied the disaster scenario development according to heavy snow and the response and support system to the features of each regional. For the scenario deduction, we preferentially collected day snowfall and disaster yearbook data to regionals, classified similar pattern and plotted GIS snow map. We also classified heavy snow disaster by region and type and we deduced five-step scenario. The five-step scenario is nationwide(1st-stage), the National Capital region(2nd-stage), the Chungcheong Provinces(3rd-stage), the Kangwon province(4th-stage) and the Ch?l a provinces(5th-stage). Therefore we build near provinces support system according to five-step scenario.

Design of Operation Management Check Items of Efficient Information System for Improvement of Business Continuity based on ISO 22301 (ISO22301 기반 비지니스 연속성 증대를 위한 효율적인 정보시스템 운영감리 점검항목 설계)

  • Joo, Nak Wan;Kim, Dong Soo;Kim, Hee Wan
    • Journal of Service Research and Studies
    • /
    • v.9 no.2
    • /
    • pp.31-40
    • /
    • 2019
  • In this paper, we have studied the improvement of operational control for the enhancement of business continuity of information system becoming more important with the development of information technology such as big data, Iot, and artificial intelligence. The operational management and audit guidance of the current information system, which is coming in the fourth industrial age, where various services, data and industries are converged, is based on the existing general information system pattern and needs to be improved. The provision of services at fixed times is linked to the survival of enterprises and countries and serves as a key element. Therefore, it is necessary to study the application of optimized check items of the operation audits to minimize the service interruption damage of the information system and to provide the stable service in terms of business continuity management. To accomplish this, the check items presented in the operational control of the information system were derived by combining the PDCA step contents and 8 resource requirements provided in ISO 22301. From the point of view of increasing the business continuity according to the derivation criteria of the inspection items, the operational inspection check items were derived by exemplifying the improved check items and review items of the information system operation audit and the products to be checked during the operational audit. The check items were divided into management audit improvement check items for service continuity management, and operational audit improvement check items for performance and availability management. The average score of the IT professionals' survey on the suitability of the proposed checklist was 4.63, which was concluded to be appropriate.

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System (원추형 마찰진자베어링의 내진성능평가)

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Kyung-Rock;Kim, Nam-Sik;Jung, Duk-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.23-33
    • /
    • 2011
  • In this study, a CFPBS (Cone-type Friction Pendulum Bearing System) was developed which controls the acceleration delivered to the structure to prevent damage and degradation of the critical communication equipment in case of an earthquake. The isolation performance of the CFPBS was evaluated by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced from the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with the seismic isolator system consisting of four CFPBSs. In order to verify its earthquake-resistant performance, a numerical analysis program was created from the equation of the CFPBS induced from the equations of motion. A simplified theoretical equation of the CFPBS was proposed to manufacture the equipment which could demonstrate the necessary performance. Artificial seismic waves satisfying the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and skew angle of the friction surface were considered for numerical analysis with El Centro NS (1940), Kobe NS (1995) and artificial seismic waves. The CFPBS isolation performance evaluation was based on the results of numerical analysis and the executed comparative analysis between the results from numerical analysis and the simplified theoretical equation under the same conditions.

A Case of Acute Fibrinous and Organizing Pneumonia (급성 섬유소성 기질화 폐렴 1예)

  • Cho, Joo Yeon;Lee, Hyun Kyung;Lee, Sung Soon;Lee, Hye Kyung;Lee, Young Min;Lee, Hyuk Pyo;Kim, Joo In;Choi, Soo Jeon;Yum, Ho-Kee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.5
    • /
    • pp.479-483
    • /
    • 2006
  • Acute fibrinous and organizing pneumonia (AFOP) is a histological pattern consisting of prominent intra-alveolar fibrin and organizing pneumonia, with out hyaline membranes or prominent eosinophilia. The clinical manifestations of AFOP resemble those of acute lung injury such as acute interstitial pneumonia (AIP). However, the classic histological patterns of AFOP differ from diffuse alveolar damage (DAD), bronchiolitis obliterans with organizing pneumonia (BOOP) or acute eosinophilic pneumonia (AEP). The characteristic intra-alveolar fibrin ball and lack of classic hyaline membrane are the predominant histological features of AFOP. Although some reports suggest that its clinical course is less catastrophic than DAD, the clinical entity that distinguishes AFOP from DAD has not been established. We present a case of pathologically demonstrated AFOP in a 79-year-old man. The radiological findings of our case were similar to those of DAD, presented with diffuse bilateral lung infiltrations. However, despite the rapid development of respiratory failure, the patient had a better response and outcome to steroid therapy than what would be expected for DAD.

Effect of Sucralfate on Radiation-induced Esophageal Changes in Rat (방사선 조사에 따른 흰쥐 식도변화의 Sucralfate 효과)

  • Kang, Ki-Mun;Chai, Gyu-Young;Yoon, Sei-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.367-374
    • /
    • 2001
  • The study was designed to evaluate the response of sucralfate against the esophageal damage of rat by irradiation. Sixty Sprague-Dawley rats weighing 200-250 gm were divided into six groups including only sucralfate group, the group of 10 Gy or 20 Gy radiation alone, the groups of 10 Gy or 20 Gy radiation-sucralfate combination, and control. Each group was sacrificed at 3, 7, 14, and 28 days after irradiation. For evaluation of the radiation-induced esophageal lesions, there were examined the change of body weight, barium-esophagogram and histopathologic findings. Mean body weight gain was decreased in the groups with 10 Gy or 20 Gy radiation alone and 10 Gy or 20 Gy radiation-sucralfate combination as comparing with control (p=0.03, p=0.02, p=0.04, p=0.02), but there was no difference between the groups of 10 Gy or 20 Gy radiation alone and the groups of 10 Gy or 20 Gy radiation-sucralfate combination. In the 10 Gy and 20 Gy radiation alone groups, barium esophagograms showed diffuse narrowing and stiffness through the entire esophagus from 7 days after irradiation, but there was similar pattern of esophagograms between the groups of 10 Gy radiation-sucralfate combination and the control. Histopathoiogic lesion scores of 10 Gy and 20 Gy radiation groups were significantly higher than the control (p=0.03, p=0.008). In the 10 Gy radiation group, there were significantly higher lesion scores at 3 and 7 days after irradiation as comparing with those in the group of radiation-sucralfate combination (p=0.04, p=0.03). These results suggest that sucralfate might be played as a role of protection from acute radiation-induced esophagitis within the limit of tolerable radiation doses.

  • PDF

The Nondestructive Analysis of the Pigments on the Korean 12-fold scheen, Haehakbando-do (해학반도도 채색안료에 대한 비파괴 특성 분석)

  • Kim, Gyu-ho;Song, Yuo-na;Lim, Duck-su;Song, Jeong-ju
    • 보존과학연구
    • /
    • s.28
    • /
    • pp.121-147
    • /
    • 2007
  • A large variety of mineral pigments has been used for Korean paintings and it has known that organic pigments have been used together on the Buddhist painting and the portrait. Haehakbando-do, which is from Honolulu Academy Museum in the United States, 12-fold screen was commissioned by Court of the late Joseon Dynasty in order to pray for the King's longevity. Therefore, it seems that all material used including pigments were selected very carefully and a great deal of technical effort was gone into its process. The purposes of this research were to estimate the pigments and the contributory elements of each color used on Haehakbando-do, in accordance with the conservation treatment carried out by Gochang Conservation Institute throughout last year. Without extracting sample, property of pigment was measured by nondestructive method, X-ray spectral analysis, and by comparing with the data about ancient pigments. In spite of the limited range of pigment analysis by nondestructive method, it should be noted that this method would not cause damage to the cultural properites. White pigment was found in all colored parts except the background, so it can be suggested that white color was used as a grounding of other color pigments. This would be flake white[$2PbCO_3{\cdot}Pb(OH)_2$] as Pb was found. Pb was the only element could be found in yellow, however, it can be organic pigment like Gamboge as same as background. Red would be Cinnabar (HgS) as hydrargyrum (Hg) was detected. For the light purple in cloud, organic pigments were probably used since any element is not detected except for Pb, which is used for background. It is possible that green color is the mixture of Malachite[$CuCO_3{\cdot}Cu(OH)_2$] and Azurite [$2CuCO_3{\cdot}Cu(OH)_2$], which share Cu as their main element. Azurite[$2CuCO_3{\cdot}Cu(OH)_2$] was used for bluish pigments. Black is carbon compound. For gold, solid gold (Au) was detected. It shows that gold was gilded on the flake white background. Red painted on the frame of screen was identified as Cinnabar (HgS) and the gold pattern was solid gold (Au). The supporting leg of folding screen was made of brass because both copper and zinc were detected. In conclusion, white pigment was used as grounding of all colors of Haehakbando-do, and specific pigments were used for each color. Additionally, result from the analysis of several pigments shows that mineral pigment and organic pigment, or different mineral pigments were mixed to make various colors.

  • PDF

A Study of Web Application Attack Detection extended ESM Agent (통합보안관리 에이전트를 확장한 웹 어플리케이션 공격 탐지 연구)

  • Kim, Sung-Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.1 s.45
    • /
    • pp.161-168
    • /
    • 2007
  • Web attack uses structural, logical and coding error or web application rather than vulnerability to Web server itself. According to the Open Web Application Security Project (OWASP) published about ten types of the web application vulnerability to show the causes of hacking, the risk of hacking and the severity of damage are well known. The detection ability and response is important to deal with web hacking. Filtering methods like pattern matching and code modification are used for defense but these methods can not detect new types of attacks. Also though the security unit product like IDS or web application firewall can be used, these require a lot of money and efforts to operate and maintain, and security unit product is likely to generate false positive detection. In this research profiling method that attracts the structure of web application and the attributes of input parameters such as types and length is used, and by installing structural database of web application in advance it is possible that the lack of the validation of user input value check and the verification and attack detection is solved through using profiling identifier of database against illegal request. Integral security management system has been used in most institutes. Therefore even if additional unit security product is not applied, attacks against the web application will be able to be detected by showing the model, which the security monitoring log gathering agent of the integral security management system and the function of the detection of web application attack are combined.

  • PDF

Prediction of a Debris Flow Flooding Caused by Probable Maximum Precipitation (가능 최대강수량에 의한 토석류 범람 예측)

  • Kim, Yeon-Joong;Yoon, Jung-Sung;Kohji, Tanaka;Hur, Dong-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.2
    • /
    • pp.115-126
    • /
    • 2015
  • In recent years, debris flow disaster has occurred in multiple locations between high and low mountainous areas simultaneously with a flooding disaster in urban areas caused by heavy and torrential rainfall due to the changing global climate and environment. As a result, these disasters frequently lead to large-scale destruction of infrastructures or individual properties and cause psychological harm or human death. In order to mitigate these disasters more effectively, it is necessary to investigate what causes the damage with an integrated model of both disasters at once. The objectives of this study are to analyze the mechanism of debris flow for real basin, to determine the PMP and run-off discharge due to the DAD analysis, and to estimate the influence range of debris flow for fan area according to the scenario. To analyse the characteristics of debris flow at the real basin, the parameters such as the deposition pattern, deposit thickness, approaching velocity, occurrence of sediment volume and travel length are estimated from DAD analysis. As a results, the peak time precipitation is estimated by 135 mm/hr as torrential rainfall and maximum total amount of rainfall is estimated by 544 mm as typhoon related rainfall.