• Title/Summary/Keyword: Patients with cancer

Search Result 9,735, Processing Time 0.044 seconds

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

Ultrafast MRI and T1 and T2 Radiomics for Predicting Invasive Components in Ductal Carcinoma in Situ Diagnosed With Percutaneous Needle Biopsy

  • Min Young Kim;Heera Yoen;Hye Ji;Sang Joon Park;Sun Mi Kim;Wonshik Han;Nariya Cho
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1190-1199
    • /
    • 2023
  • Objective: This study aimed to investigate the feasibility of ultrafast magnetic resonance imaging (MRI) and radiomic features derived from breast MRI for predicting the upstaging of ductal carcinoma in situ (DCIS) diagnosed using percutaneous needle biopsy. Materials and Methods: Between August 2018 and June 2020, 95 patients with 98 DCIS lesions who underwent preoperative breast MRI, including an ultrafast sequence, and subsequent surgery were included. Four ultrafast MRI parameters were analyzed: time-to-enhancement, maximum slope (MS), area under the curve for 60 s after enhancement, and time-to-peak enhancement. One hundred and seven radiomic features were extracted for the whole tumor on the first post-contrast T1WI and T2WI using PyRadiomics. Clinicopathological characteristics, ultrafast MRI findings, and radiomic features were compared between the pure DCIS and DCIS with invasion groups. Prediction models, incorporating clinicopathological, ultrafast MRI, and radiomic features, were developed. Receiver operating characteristic curve analysis and area under the curve (AUC) were used to evaluate model performance in distinguishing between the two groups using leave-one-out cross-validation. Results: Thirty-six of the 98 lesions (36.7%) were confirmed to have invasive components after surgery. Compared to the pure DCIS group, the DCIS with invasion group had a higher nuclear grade (P < 0.001), larger mean lesion size (P = 0.038), larger mean MS (P = 0.002), and different radiomic-related characteristics, including a more extensive tumor volume; higher maximum gray-level intensity; coarser, more complex, and heterogeneous texture; and a greater concentration of high gray-level intensity. No significant differences in AUCs were found between the model incorporating nuclear grade and lesion size (0.687) and the models integrating additional ultrafast MRI and radiomic features (0.680-0.732). Conclusion: High nuclear grade, larger lesion size, larger MS, and multiple radiomic features were associated with DCIS upstaging. However, the addition of MS and radiomic features to the prediction model did not significantly improve the prediction performance.

Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise

  • Joo Hee Kim;Hyun Jung Yoon;Eunju Lee;Injoong Kim;Yoon Ki Cha;So Hyeon Bak
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.131-138
    • /
    • 2021
  • Objective: Iterative reconstruction degrades image quality. Thus, further advances in image reconstruction are necessary to overcome some limitations of this technique in low-dose computed tomography (LDCT) scan of the chest. Deep-learning image reconstruction (DLIR) is a new method used to reduce dose while maintaining image quality. The purposes of this study was to evaluate image quality and noise of LDCT scan images reconstructed with DLIR and compare with those of images reconstructed with the adaptive statistical iterative reconstruction-Veo at a level of 30% (ASiR-V 30%). Materials and Methods: This retrospective study included 58 patients who underwent LDCT scan for lung cancer screening. Datasets were reconstructed with ASiR-V 30% and DLIR at medium and high levels (DLIR-M and DLIR-H, respectively). The objective image signal and noise, which represented mean attenuation value and standard deviation in Hounsfield units for the lungs, mediastinum, liver, and background air, and subjective image contrast, image noise, and conspicuity of structures were evaluated. The differences between CT scan images subjected to ASiR-V 30%, DLIR-M, and DLIR-H were evaluated. Results: Based on the objective analysis, the image signals did not significantly differ among ASiR-V 30%, DLIR-M, and DLIR-H (p = 0.949, 0.737, 0.366, and 0.358 in the lungs, mediastinum, liver, and background air, respectively). However, the noise was significantly lower in DLIR-M and DLIR-H than in ASiR-V 30% (all p < 0.001). DLIR had higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than ASiR-V 30% (p = 0.027, < 0.001, and < 0.001 in the SNR of the lungs, mediastinum, and liver, respectively; all p < 0.001 in the CNR). According to the subjective analysis, DLIR had higher image contrast and lower image noise than ASiR-V 30% (all p < 0.001). DLIR was superior to ASiR-V 30% in identifying the pulmonary arteries and veins, trachea and bronchi, lymph nodes, and pleura and pericardium (all p < 0.001). Conclusion: DLIR significantly reduced the image noise in chest LDCT scan images compared with ASiR-V 30% while maintaining superior image quality.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Effectiveness of a Custom-made Multi Purpose Brachytherapy Phantom (자체 제작한 근접방사선치료용 다목적 팬텀의 유용성 평가)

  • Jang, In-Gi;Lee, Jin-Joung;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2006
  • Purpose: To measure the dose for dose optimization at the reference point (A, B) and the critical organ with multi Purpose brachytherapy phantom (MPBP). For this wort the MPBP was custom made, and designed to reconstruct the treatment applicator using multi function applicator (MFA) in the same way as the treatment of patient. Materials and Methods: Dose measurements were made at the reference points (A, B) and the bladder with thermoluminescence dosimeter (TLD) for four patients with tandem and ovoid of uterine cervix cancer using the phantom. In Phantom, Total 20 times of the measurements were made with 5 times a patient. Results: The results of TLD measurements in MPBP phantom showed the relative error ranging from -3.2% to 3.8% at A point, and -1.4% to 4% at B point and 1.3% to 7.15% at the bladder of reference point. Conclusion: The reproducibility of dose measurement under the same condition as the treatment could be achieved using the custom-made MFA in phantom and the dose at the reference point (A, B) and bladder could be analyzed accurately. The measured dose acquired in MPBP can apply for the dose optimization.

  • PDF

A Case of Squamous Cell Carcinomatous Lung Abscess with Multiple Metastatic Abscesses (다발 전이성 농양을 일으킨 편평상피세포암성 농양 1예)

  • Lim, Ju Eun;Kim, Eun Young;Jang, Ji Eun;Son, Ji-Young;Jung, Ji Ye;Park, Byung Hoon;Lee, Kyung Jong;Yoon, Yeo Wun;Byun, Min Kwang;Lee, Sa Rah;Kang, Young Ae;Moon, Jin Wook;Park, Moo Suk;Kim, Young Sam;Jang, Joon;Park, Young Nyun;Kim, Se Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.5
    • /
    • pp.390-395
    • /
    • 2009
  • Among the bronchogenic carcinomas, especially squamous cell carcinoma and large cell carcinoma frequently present with cavitation, which may result from tumor necrosis. Cavitary lesions of the tumor are occasionally associated with infection and misdiagnosed as benign lung abscess owing to the partial responsiveness to antibiotics. It is very difficult to distinguish the carcinomatous abscess from the benign lung abscess, because of their similar clinical and radiologic features. Delay in diagnosis of underlying lung cancer may result in poor outcome. Therefore, clinicians should remember that the patients with highly suspicious carcinoma of the lung should undergo further precise examinations to find out malignant cells.

Percutaneous Drainage of Lung Abscess and Infected Bulla (폐농양과 감염성 낭포의 경피적 배농술)

  • Kim, Gun-Ho;Hwang, Young-Sil;Kim, Hyung-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.120-126
    • /
    • 1994
  • Background : Antibiotic therapy has proven an effective method of treatment on the majority of patients with pyogenic lung abscess and infected bulla. When medical therapy has failed, pulmonary resection is the current generally recommended therapy. But nowdays complications of percutaneous tube drainage has decreased with the use of small catheter. So we evaluated the effect of percutaneous tube drainage as an alternative therapy to the pyogenic lung abscess and infected bulla refractory to medical therapy in preference ot the pulmonary resection. Method : Nine cases of the lung abscess and three cases of infected bulla which has large cavity size over 6cm, and has underlying diseases such as lung cancer, diabetes mellitus, refractory to over 1 week of antibiotics, were performed percutaneous tube drainage with All Purpose Drainage catheter(Medi-tech, Watertown, USA) under fluoroscopy. Results : All the cases except one case which complicated empyema was improved clinically. Fever was down within 4days of percutaneous tube drainage(mean : 1.9days). Mean duration of tube drainage was 9.9days. Conclusion : Percutaneous tube drainage is an effective and relatively safe procedure in the management of lung abscesses that do not response to medical therapy. We speculate this procedure should be considered as an alternative therapy for the lung abscess refractory to medical therapy in preference to the surgery. The safety and effectiveness of this procedure in infected bulla should be evaluated with an additional study.

  • PDF

Efficacy of Lens Shielding Device to Prevent Cataract with Radiotherapy for Orbit or Ocular Adnexal Tumor (안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성)

  • Cho, Jung-Keun;Cho, Hyun-Sang;Han, Tae-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.139-144
    • /
    • 2007
  • Radiotherapy which is the most effective for orbit lymphoma has been used increasingly due to the increase of orbit or ocular adnexal tumor patients. Curative effects and convalescence have been being more satisfied thanks to remarkable development of cancer chemotherapy and medical treatments, but side effects such as cataract, dry eye and retinopathy still break out. Thus, in this study, a Lens Shielding Device (LSD hereafter) was designed to prevent occurring of cataract due to radiation therapy for orbit lymphoma and its efficacy through dosimetry were evaluated. And in this paper, its manufacturing process was also explained. LSD is composed of a cover body covering the lens and a side fixing part supporting the cover body. To measure radiation, the patient therapy conditions were simulated and the measurement of the radiation was conducted with Thermo Luminescence Detector (TLD) and Markus chamber. The average TLD value was 5.7% and the TLD value and Markus chamber value were acquired as 4.2% and 5.1% respectively at 6 mm depth where zero lens center was located. Only 1.5Gy ($300Gy{\times}\;5%$) or 5% of total 30Gy with 9 MeV electron beam is estimated to affect on patient's lens. That is smaller dose than the threshold value of cataract (2GY) or the value (5Gy) that was reported to cause cataract in clinical conditions. Thus, these findings suggest that LSD be very useful for prevention of cataract during radiotherapy for malignant lymphoma of orbit and ocular adnexa. Furthermore, it might be possible to reduce patient's discomfort caused by alien substances and to make it easier to fix the device with customized manufacturing manners.

APPLICATION OF 0.2% HYALURONIC ACID GEL IN ORAL SURGICAL WOUND : A RANDOMIZED DOUBLE-BLIND STUDY (구강내 외과적 창상 치유에서 0.2% hyaluronic acid gel의 유효성에 대한 이중 맹검 연구)

  • Kim, Jae-Yoon;Lee, Jin-Yong;Bae, Kwang-Hak;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.157-165
    • /
    • 2008
  • The aim of this study was to evaluate the efficacy of a topical 0.2% hyaluronic acid (HA) preparation in the management of wound after removal of arch bar for facial bone fracture and a suture site after orthognatic, oral cancer or oral surgery. Forty patients participated in a randomized, placebo controlled, double-blind trial to evaluate the efficacy of the topical HA and preparation. HA topically applied to the wound after removal of arch bar or stitch out, 3 times a day for 4 weeks. Evaluation is performed once a week for 4 weeks. For subjective evaluation, relative pain reduction in visual analog scale (VAS) and existence of heat sensation was accessed. For objective evaluation, gross evaluation, papilla index, existence of wound dehiscence, redness and swelling was checked. The same evaluation was performed in each arch bar group and suture group. For whole subject, 0.2% HA group resulted higher reduction than placebo group in pain of site in first week with significancy. Same findings were seen other weeks but there was no significancy. 0.2% HA group had better result than placebo in objective evaluation (papilla index, wound dehiscence, redness and swelling), but in gross evaluation placebo had better result than 0.2% HA group with no significancy. Subject was divided into suture group and arch bar group. Same aspect was seen, but only suture group had significancy not arch bar group in pain reduction score. 0.2% HA group resulted higher reduction than placebo group in pain of site in first week with significancy, especially in suture group. It reveals topical application of HA in wound especially suture site reduced pain in early stage. And 0.2% HA group had better result than placebo in papilla index, redness and swelling with no statistical significancy. In conclusion, HA has effect of pain reduction and healing promotion in the mucosal wound after oral surgery.

Comparison of Radionuclide Bone and Gallium Scans in the Therapeutic Evaluation of Bone Lymphoma (골임파종의 치료효과판정을 위한 핵의학적 골스캔과 갈륨스캔의 비교)

  • Moon Tae-Yong;Hwang, In-Tae;Kim, E. Edmund
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.377-383
    • /
    • 1994
  • Objective : We retrospectively analysed $^{99m}Tc$-MDP bone and $^{67}Ga$ scans to evaluate therapeutic response of bone lymphoma among patients with complete remission. Subjects and Methods : We reviewed 35 cases with an increased uptake finding $^{99m}Tc$-MDP bone scans and 16 $^{67}Ga$ scans that were follow-up studies during and after therapy. The $^{99m}Tc$-MDP bone and $^{67}Ga$ scans were graded visually from 1 to 4 in which grade 3 means same uptake density as that of normal sacroiliac articulation in bone scan and normal liver in $^{67}Ga$ scan, respectively. Results: The improvement findings during and after therapy were found in 66.0% (19/ 29) and 72.7% (24/33) with $^{99m}Tc$-MDP bone scan, 84.6% (l1/13) and 86.7% (13/15) with $^{67}Ga$ scan, respectively. The mean grades of the uptake density in $^{99m}Tc$-MDP bone scan were 3.06 before, 2.34 during, 1.75 after therapy. Those in the $^{67}Ga$ scan were 3.22 before, 1.42 during 1.30 after therapy. Conclusion. $^{67}Ga$ scans appeared more sensitive than bone scans in evaluating therapeutic response of bone lymphoma.

  • PDF