• Title/Summary/Keyword: Patients Radiation Dose

Search Result 1,501, Processing Time 0.024 seconds

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Radiation Therapy of Nasopharyngeal Carcinoma (비인두강 종양의 방사선치료성적)

  • Nho Young Ju;Cho Jeong Gill;Ahn Seung Do;Choi Eun Kyung;Kim Jong Hoon;Kang One Chul;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.305-313
    • /
    • 1997
  • Purpose : This is a retrospective study to evaluate the results of radiation therapy and prognostic factors influencing the results in nasopharyngeal carcinoma. Materials and Methods: From October 1989 to May 1996. 56 Patients were treated for nasopharyngeal carcinoma at Department of Radiation On-cology. According to stage, patients were distributed as follows : stage I (2), II (13). II (11), IV (30). Twenty-eight patients were treated with radiation therapy only, 7 patients were treated with neoadiuvant chemotherapy followed by radiation therapy. Twenty-one Patients were treated with radiation therapy and weekly CDDP. After external beam radiotherapy of 60Gy, 46Patients received boost dose with intracavitary radiation and 9 Patients with 3D conformal therapy. One patient received boost dose with 2 dimensional Photon beam therapy. The tumor dose ranged from 69.4Gy to 86.2Gy with median dose of 74.4Gy. The follow-up Period ranged from 5 months to 92 months with a median of 34 months. Results : Forty-seven patients achieved complete response and 8 Patients showed partial response. One Patient showed minimal response. Patterns of failure were as follows : locoregional recurrence (8) and distant metastasis (18). Among these patients, 2 patients failed locoregionally and distantly. The sites of distant metastasis were bone (8), lung (8) and liver (4). Five years survival rate was $67.2\%$ and 5 years disease-free survival rate was $53.6\%$. KPS (P=0.005) and response ol radiation therapy (P=0.0001) were significant prognostic factors for overall survival. KPS (P= 0.02) and response of radiation therapy (P=0.005) were significant Prognostic factors for disease-free survival. Conclusion : This retrospective study showed that distant metastasis was the Predominant pattern of relapse in nasopharyngeal cancer Neoadiuvant chemotherapy or weekly CDOP did not influence the distant metastasis-free survival. For advanced T stage, 3D conformal therapy Provided an improved dose coverage compared to ICR But further follow-up was needed in Patients with 3D conformal therapy to assess the efficacy of this therapy. Development of techniques of radiation therapy to improve locoregional control and of more effective systemic chemotherapy regimen are needed.

  • PDF

Endobronchial Brachytherapy for Malignant Airway Obstruction: Low Dose Rate Versus High Dose Rate (악성 종양에 의한 기도폐쇄시 내기관지 근접치료 : 저선량 치료 대 고선량 치료의 비교)

  • Cho, Young-Kap
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 1996
  • Purpose : This is a retrospective study to compare the Palliation rates, survival rates and complications of low dose rate and high dose rate endobronchial brachytherapy in the management of malignant airway obstruction. Materials and methods : Forty three consecutive patients with malignant airway compromise from primary or metastatic lung tumors were treated with low dose rate(LDR) endobronchial Iridium-192 insertion(21 patients) between October 1988 and June 1992, and high dose rate(HDR) endobronchial brachytherapy(22 patients) between August 1992 and April 1994 with palliative aim Flexible fiberoptic bronchoscopy under fluoroscopic control was utilized in all 91 procedures. Twenty seven LDR Procedures delivered a dose of 5-7.5 Gy to a 1.0 cm radius respectively. Results : Subjective and objective responses to treatments were evaluated on follow-up examinations by clinical examination, chest x-rays and CT scan of the chest on some patients. Fifteen of 21 LDR patients and 19 of 22 HDR Patients showed subjective improvement in terms of better breathing and less Productive cough as well as complete disappearance of hemoptysis. Objective improvement on chest x-rays and CT scan of the chest had been demonstrated on 8 LDR Patients and 10 HDR patients. Conclusion : The technique of LDR and HDR endobronchial brachytherapy is simple and well tolerated procedure with minimal morbidity It Provides excellent palliation by keeping airway Patent in these short life-spanned patients.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Phase II Study on Breast Conservative Surgery Plus Chemo- and Radiotherapy in Treating Chinese Patients with Early Staged Breast Cancer

  • Liu, Yang-Chen;Zhou, Shao-Bing;Gao, Fei;Yin, Xiao-Xiang;Zhao, Ying;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3747-3750
    • /
    • 2013
  • Purpose: To evaluate the efficacy of conservative surgery plus chemo-, radio-therapy in treating patients with early stage breast cancer. Patients and Methods: Eligible patients were treated by postoperative chemotherapy as well as whole-breast irradiation with tumor bed boost. Postoperative radiotherapy consisted of 6 MV whole breast linear accelerator irradiation with two tangential half fields to a total dose of 45~50 Gy, followed by $10{\sim}15MeV{\beta}$ boost irradiation to tumor bed for 10~20Gy, total dose 56~66Gy. Results: Fifty-two patients were enrolled. Overall 1-, 2- and 3 year survival rates were 98.1%, 92.3%, and 90.4%, respectively, with a local recurrence rate of 5.77%. Cosmetic results were evaluated as good by doctors in 90.4% of patients. Conclusions: Breast conservative surgery combined with chemo- radio-therapy could be a treatment option for Chinese patients with early stage breast cancer.

TA Study on Patient Exposure Dose Used the Phantom for Interventional Procedure (중재적 시술 시 팬텀을 이용한 환자의 피폭선량 분석)

  • Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • Because interventional procedure operates looking at premier as real time when perate intervention enemy, by patient is revealed during suitableness time in radiation, side effect such as radiation injury of skin is apt to happen. It established by purpose of study that measure exposure dose that patient receives about these problem, and find solution for radiation injury and repletion method. In this study, we used Rando phantom of identical structure with the human body which becomes accomplished with 4 branch ingredient of the attempt and system equivalent material them and absorbed dose were measured by TLD. According to the laboratory, it shows that operations such as TFCA procedure or uterine myoma embolization are more dangerous than TACE procedure. If both operations are inspected during a short time, it is not affected in being bombed. However, it can lead to palliative agenesis or depilate, definitive agenesis only if operations are repeated more than three times. Dose distibution based on experiment, to reduce radiation exposure to patients result from reduction of scatter ray as we control field size of radiation and protection of side organs except for tumor. also we knew that we can protect patients form radiation exposure, if we increas SOD and decrease SID.

  • PDF

Influence of Intravenous Contrast Medium on Dose Calculation Using CT in Treatment Planning for Oesophageal Cancer

  • Li, Hong-Sheng;Chen, Jin-Hu;Zhang, Wei;Shang, Dong-Ping;Li, Bao-Sheng;Sun, Tao;Lin, Xiu-Tong;Yin, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1609-1614
    • /
    • 2013
  • Objective: To evaluate the effect of intravenous contrast on dose calculation in radiation treatment planning for oesophageal cancer. Methods: A total of 22 intravein-contrasted patients with oesophageal cancer were included. The Hounsfield unit (HU) value of the enhanced blood stream in thoracic great vessels and heart was overridden with 45 HU to simulate the non-contrast CT image, and 145 HU, 245 HU, 345 HU, and 445 HU to model the different contrast-enhanced scenarios. 1000 HU and -1000 HU were used to evaluate two non-physiologic extreme scenarios. Variation in dose distribution of the different scenarios was calculated to quantify the effect of contrast enhancement. Results: In the contrast-enhanced scenarios, the mean variation in dose for planning target volume (PTV) was less than 1.0%, and those for the total lung and spinal cord were less than 0.5%. When the HU value of the blood stream exceeded 245 the average variation exceeded 1.0% for the heart V40. In the non-physiologic extreme scenarios, the dose variation of PTV was less than 1.0%, while the dose calculations of the organs at risk were greater than 2.0%. Conclusions: The use of contrast agent does not significantly influence dose calculation of PTV, lung and spinal cord. However, it does have influence on dose accuracy for heart.

Exposure Dose of DIPS in Proton Therapy for Pediatric Cancer Patients (소아암 환자의 양성자치료 시 DIPS 촬영에 따른 피폭선량)

  • Kim, Jeong-Soo;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • We investigated the radiation exposure caused by DIPS, which is used to identify accurate repositioning and tumor location in pediatric cancer patients proton therapy. To compare and analyze DIPS condition, 50 pediatric cancer patients who underwent proton therapy were selected in Ilsan K cancer-specialized hospital from March 2007 to October 2009. For DIP exposure, 0.09~1.57 mGy is measured in AP and lateral directions and 23.55 mGy is measured in CSI patients. In whole brain patient, the amount of a day DIP exposure dose was 1.13 mGy. During treatment period, who exposed the biggest DIP dose are whole brain patients, 632.71 mGy is exposed. It is 1.13% of prescribed dose, represented dose is adequate because it is not exceeded 2% of recommended dose. Even though the exposed dose is not exceeded more than 2% of prescribed in DIP exposure, we should recognize the radiation damage and genetic influences to pediatric cancer patients, who is much sensitive to radiation and has longer mean residual life time. Therefore, DIPS guideline for pediatric cancer patients should be indicated to minimize the radiation exposure.

Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography (심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가)

  • Yong-In Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

Radiotherapy for pituitary adenomas: long-term outcome and complications

  • Rim, Chai-Hong;Yang, Dae-Sik;Park, Young-Je;Yoon, Won-Sup;Lee, Jung-Ae;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.156-163
    • /
    • 2011
  • Purpose: To evaluate long-term local control rate and toxicity in patients treated with external beam radiotherapy (EBRT) for pituitary adenomas. Materials and Methods: We retrospectively reviewed the medical records of 60 patients treated with EBRT for pituitary adenoma at Korea University Medical Center from 1996 and 2006. Thirty-five patients had hormone secreting tumors, 25 patients had non-secreting tumors. Fifty-seven patients had received postoperative radiotherapy (RT), and 3 had received RT alone. Median total dose was 54 Gy (range, 36 to 61.2 Gy). The definition of tumor progression were as follows: evidence of tumor progression on computed tomography or magnetic resonance imaging, worsening of clinical sign requiring additional operation or others, rising serum hormone level against a previously stable or falling value, and failure of controlling serum hormone level so that the hormone level had been far from optimal range until last follow-up. Age, sex, hormone secretion, tumor extension, tumor size, and radiation dose were analyzed for prognostic significance in tumor control. Results: Median follow-up was 5.7 years (range, 2 to 14.4 years). The 10-year actuarial local control rates for non-secreting and secreting adenomas were 96% and 66%, respectively. In univariate analysis, hormone secretion was significant prognostic factor (p = 0.042) and cavernous sinus extension was marginally significant factor (p = 0.054) for adverse local control. All other factors were not significant. In multivariate analysis, hormone secretion and gender were significant. Fifty-three patients had mass-effect symptoms (headache, dizziness, visual disturbance, hypopituitarism, loss of consciousness, and cranial nerve palsy). A total of 17 of 23 patients with headache and 27 of 34 patients with visual impairment were improved. Twenty-seven patients experienced symptoms of endocrine hypersecretion (galactorrhea, amenorrhea, irregular menstruation, decreased libido, gynecomastia, acromegaly, and Cushing's disease). Amenorrhea was abated in 7 of 10 patients, galactorrhea in 8 of 8 patients, acromegaly in 7 of 11 patients, Cushing's disease in 4 of 4 patients. Long-term complication was observed in 4 patients; 3 patients with cerebrovascular accident, 1 patient developed dementia. Of these patients, 3 of 4 received more than 60 Gy of irradiation. Conclusion: EBRT is highly effective in preventing recurrence and reducing mass effect of non-secreting adenoma. Effort to improve tumor control of secreting adenoma is required. Careful long-term follow-up is required when relatively high dose is applied. Modern radiosurgery or proton RT may be options to decrease late complications.