• Title/Summary/Keyword: Patient table

Search Result 206, Processing Time 0.033 seconds

The Effect of Midazolam As Sedative Agent in Bronchoscopy (기관지내시경 검사시 전처치로서 Midazolam의 효과)

  • Lee, Sang-Haak;Hyun, Dae-Sing;Lee, Sook-Young;Kim, Seok-Chan;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.612-618
    • /
    • 2002
  • Background : Bronchoscopy is an important diagnostic and a therapeutic tool in chest medicine. However, most patients feel that a bronchoscopy is an unpleasant procedure, and it is important to sedate the patients appropriately, particularly where repetitive examinations are required. Midazolam is a sedative drug with amnestic qualities and a rapid 2 hour half-life. This study have attempted to determine the safety, appropriate dosage, and the effect of midazolam premedication in patients who underwent a bronchoscopy. Methods : One hundred and eighty consecutive patients undergoing bronchoscopy were enrolled in this study. The patients received a midzolam doses of 0.03 mg/kg, 0.06 mg/kg, or a placebo. An additional dose of lidocaine, the total number of coughs, and the duration of the procedures were recorded with monitoring the the blood pressure, heart rate, and oxygen saturation. The level of satisfaction was assessed by the patient, bronchoscopist, and the nurse. Results : The blood pressure, pulse rates, oxygen saturation, number of coughs, lidocaine dose, and procedure time in the 3 groups were similar. There was a trend for the midazolam 0.03 mg/kg group to satisfy bronchoscopists more than the other two groups. The nurses' acceptability was lower in the midazolam 0.06 mg/kg group than the other groups. The patients' acceptablity was greater in both the midazolam 0.03 mg/kg and 0.06 mg/kg groups than in the control group. Conclusion : Sedation with low doses of intravenous midazolam is a safe technique for fiberoptic bronchoscopy with a low morbidity and high acceptable to patients and bronchoscopists.

Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy (토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.323-331
    • /
    • 2010
  • The Hi-Art system for TomoTherapy allows only three (1.0 cm, 2.5 cm, 5.0 cm) field widths and this can produce different dose distribution around the end of PTV (Planning target volume) in the direction of jaw movement. In this study, we investigated the effect of field width on the dose difference around the PTV using DQA (Delivery quality assurance) phantom and real clinical patient cases. In the analysis with DQA phantom, the calculated dose and irradiated films showed that the more dose was widely spreaded out in the end region of PTV as increase of field width. The 2.5 cm field width showed a 1.6 cm wider dose profile and the 5.0 cm field width showed a 4.2 cm wider dose profile compared with the 1.0 cm field width in the region of 50% of maximum dose. The analysis with four patient cases also showed the similar results with the DQA phantom which means that more dose was irradiated around the superior and inferior end of PTV as an increase of field width. The 5.0 cm field width produced the remarkable high dose distribution around the end region of PTV and we could evaluate the effect quantitatively with the calculation of DVH (Dose volume histogram) of the virtual PTVs which were delineated around the end of PTV in the direction of jaw variation. From these results, we could verify that the margin for PTV in the direction of table movement should be reduced compared with the conventional margin for PTV when the large field such as 5.0 cm was used in TomoTherapy.

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

The effective quality assurance for image guided device using the AMC G-Box (AMC G-Box를 이용한 영상유도장치의 효율적인 정도관리)

  • Kim, Chong Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose : According to the rapid increase recently in image-guided radiation therapy, It is necessary to control of the image guidance system completely. In particular for the main subject to the accuracy of image guided radiation therapy device to be done essentially the quality assurance. We made efficient phantom in AMC for the management of the accurate and efficient. Materials and Methods : By setting up of five very important as a quality assurance inventory of the Image guidance system, we made (AMC G-Box) phantom for quality assurance efficient and accurate. Quality assurance list were the Iso-center align, the real measurement, the center align of four direction, the accuracy of table movement and the reproducibility of Hounsfield Unit. The rectangular phantom; acrylic with a thickness of 1 cm to $10cm{\time}10cm{\time}10cm$ was inserted the three materials with different densities respectively for measure the CBCT HU. The phantom was to perform a check of consistency centered by creating a marker that indicates the position of the center fixed. By performing the quality assurance using the phantom of existing, comparing the resulting value to the different resulting value using the AMC G-Box, experiment was analyzed time and problems. Therapy equipment was used Varian device. It was measured twice at 1-week intervals. Results : When implemented quality assurance of an image guidance system using AMC G-Box and a phantom existing has been completed, the quality assurance result is similar in $0.2mm{\pm}0.1$. In the case of the conventional method, it was 45 minutes at 30 minutes. When using AMC G-Box, it takes 20 minutes 15 minutes, and declined to 50% of the time. Conclusion : The consistency and accurate of image guidance system tend to decline using device. Therefore, We need to perform thoroughly on the quality assurance related. It needs to be checked daily to consistency check especially. When using the AMC G-Box, It is possible to enhance the accuracy of the patient care and equipment efficiently performing accurate quality assurance.

The Study of Effect and Safety related to Dong-gi Acupuncture(DGA) and Complex therapy on Lumbago due to blood stasis and sprain (좌섬(挫閃)·어혈(瘀血) 요통(腰痛)에 동기침법(動氣鍼法) 및 복합치료(複合治療)의 유효성(有效性) 및 안정성(安定性) 연구(硏究))

  • Kim, Kee-Hyun;Lim, Hyung-Ho;Hwang, Hyeon-Seo;Song, Ho-Sueb;Song, Young-Sang;Kwon, Soon-Jung;Kim, Kyung-Nam;Ahn, Koang-Hyun;Lee, Seong-No;Kang, Mi-Suk;Gyun, Im-Jung
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.107-114
    • /
    • 2002
  • Objective : This study was designed to find the most effective and safest way to overcome Lumbago due to blood stasis and sprain involved in a few Meridian Tendino-musculatures by evaluating the effect of two kinds of Dong-gi(Dong-qi) Acupuncture(DGA) and by reporting their side effects. Material : 97 patients of out and admission patients were selected, who were diagnosed with lumbar sprain caused by repetitive bending, heavy weight lifting, unsuitable posture, concussion and falling down and whose Lumbago due to blood stasis and sprain in the concept of oriental medicine. Methods : 97 patients were divided into three groups. One is exclusive DGA group to which DGA and the method retaining needles on the acupoints for about 20 minutes were applied, the other is DGA combined active exercise group in which patients stretched their Meridian Tendino-muscuIatures with their hips moving up and downward repeatedly during DGA, the third is DGA combined passive exercise group in which patients were made to flex or extend their bodies on the auto flexion-distraction table in a prone position, from 10 to 20 degree, during DGA. In each group, bed rest, physical therapy and herbal medicine were used according to symptoms, in addition to DGA. In DGA method, "Su(Shu)" points of the meridian related to the involved Meridian Tendino-musculature were mainly chosen, that is, Sokkol(Shugu, B65), Hugye(Houxi, SI3), ChungJo(Zhongzhu, TE3) were used, for most LBP belonged to Bladder and Gallbladder Meridian Tendino-musculature disorders. Pyong-Bo-Pyong-Sa(Ping-Bu-Ping-Xie) such as Dong-Gi and Yeom-Jeon(Nian-Zhuan) was applied as Bo-Sa method. For evaluation of effectiveness, new score system was devised by severity of pain and range of movement. the score was given twice at patients' first and last visit and the difference between first and last score was regarded as a evaluation scale, the effectiveness was classified into four grade by evaluation scale.(scale : 12-15; excellent, 8-11; good, 4-7; fair, 0-3; bad) Results : 1. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed 97, 87 and 89% in effectiveness. 2. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed no aggravation of pain, range of movement. 3. In blood test of 34 patients, only one patient showed abnormal rise of sGOT, sGPT and $\gamma$-GTP at his first visit and the others didn't show any detrimental change. DGA had no bad influence upon BUN and creatinine of patients. Conclusion : For complex theraphy combining DGA, exercise, physical therapy and Herbal medicine proved to be highly effective on treating lumbago due to blood stasis and sprain, this is expected to be available for clinical use.

  • PDF

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

Sputum Smear Conversion During mDOT (Modified Directly Observed Treatment) (변형된 복약확인 치료(mDOT) 수행 후의 균음전율에 대한 연구 부제: 보건소 균양성 폐결핵 환자를 대상으로)

  • Hwang, Taik Gun;Kim, Soon Deok;Yoo, Se Hwa;Shin, Yoo Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.485-494
    • /
    • 2004
  • Background : To assess the effects of mDOT implementation on sputum smear conversion for AFB (Acid fast bacilli) positive pulmonary tuberculosis patients, modified Directly Observed Treatment (mDOT) was started on October $8^{th}$ 2001 at a health center in Seoul. mDOT was defined through weekly interviewing and supervising of a patient by a supervisor (doctor, nurse, or lay health worker). The sputum smear conversion of a mDOT group was compared with that of a self-medication (self) group. Methods : This study included 52 AFB positive pulmonary tuberculosis patients registered at a health center in Seoul between October $8^{th}$ 2001 and April $23^{rd}$ 2002. 24 and 28 patients were enrolled in the mDOT and self medication groups, respectively. Paired (1:1) individual matching, by gender, extent of disease, relapse and age-matching variables, was performed between the two groups, resulting in 20 paired matches. This prospective study was planned as an unblinded, non-randomized quasiexperimental pilot project. Outcomes were identified from results of sputum smear examinations for AFB in both groups at 2 weeks, and 1 and 2 months. The paired matching data were analyzed using the SAS program version 8.1 by McNemar test. Results : At the end of 2 weeks of treatment, the sputum smear conversion of the mDOT group was somewhat higher than that of the self medication group (78.57 vs. 50%, p-value=0.289), and after 1 month of treatment no statistically significant difference was shown between the two groups (83.33 vs. 50, p-value=0.125). At the end of 2 months of treatment (initial intensive phase), the sputum smear conversions of the mDOT and self groups were 95 and 75%, respectively (p-value=0.219). Conclusions : The implementation of mDOT did not result in clinically significant increases in the sputum smear conversion at 2 weeks, and 1 and 2 months compared with that of the self medication group. However, the increases experienced might contribute to diminishing the infectious period of AFB positive patients, and this approach may act as a guide for a specific group of patients. In this study, mDOT was performed for one hundred percent of the intensive treatment phase. It can also be an effective treatment for pulmonary tuberculosis patients, and may be useful for some high risk tuberculosis patients.

Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

A Study on Therapeutic Compliance of Hypertensive Patients in a Rural Health Subcenter (일개 농촌지역 보건지소 고혈압 환자의 치료지속성)

  • Song, Min-Keun
    • Journal of agricultural medicine and community health
    • /
    • v.27 no.1
    • /
    • pp.155-164
    • /
    • 2002
  • Hypertension is the most frequent disease of chronic circulatory diseases and major intermediate cause or risk of the cerebrovascular disease which is a leading cause of death in Korea. Therefore, management of hypertension is an important issue in Korean healthcare. Especially, therapeutic compliance of hypertensives is very important because the hypertensive patients should receive anti-hypertensive treatment as long as the condition exists. However, many patients drop out of treatment, which is a major problem that needs to be solved through a hypertension control program. This study was carried out to provide basic data and counter measule for the hypertension control program in the community which aimed to keep the patients receiving treatment continuously. In order to investigate compliance of hypertensive patients during three months follow-up and the rate of control of hypertension, the data were collected during February, 2001, by reviewing medical records of 295 hypertensive patients who had been registered to Gunnam-myeon health subcenter before November, 2000. The author also study the dropout reasons by interviewing 58 patients among 68 dropout patients. The results were as follows: 1. Among the 295 subjects, 108(36.6%) were male and 187(63.4%) were female. Statistically, female hypertensives had a higher mean age than male(64.6 vs 66.3, p<0.05). 2. The 54.9% of the patients took anti-hypertensive medicine continuously for the past three months. And 19.3% had drug intermittently, and 25.8% dropped out of treatment. 3. Among several variables, such as sex, age, health insurance, the time taken from a patient's village to the health subcenter, only the last one was found to be significantly related to therapeutic compliance in the contingency table analysis. 4. The dropout reasons by multiple response were as follows, 'no symptom or no problem' (23.9%), 'change to other hospitals'(19.4%), 'geographical barrier'(17.9%), 'change to a neighborhood drugstore' (14.9%), 'immobility'(7.5%), 'economic barrier'(6.0%), 'unsatisfactory services of the health subcenter'(4.4%). 5. The mean blood pressure of 295 subjects was $144.9{\pm}12.9/86.88{\pm}8.6mmHg$. 6. The 32.5% of the subjects were controlled below 140/90mmHg. Conclusions: In order to improve the low rates of treatment and control of hypertension in rural hypertensives, a more active and systematic hypertension control program, including out-reaching follow-up management, is required in rural area. Especially, for health education of hypertensive patients, emphasis should placed on correcting wrong attitude toward hypertension.

  • PDF