• Title/Summary/Keyword: Patient table

Search Result 208, Processing Time 0.028 seconds

Development of a Cantilevered Patient Table Considering X-ray Transparency (X-선 투과특성을 고려한 외주형 수술용 테이블 개발)

  • Won B.H.;Chun K.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.189-190
    • /
    • 2006
  • A patient table considering x-ray transparency, mechanical safety and compact multi-axis moving mechanism has been developed. The goal of medical imaging technology is to keep radiation exposure of patients during x-raying to a minimum. In order to obtain clear pictures at low dose, however, the x-ray table which supports the patient must be sufficiently permeable to radiation to allow good image resolution. The table top is made of low density foam for x-ray transparent effective area and structural aluminum plate to connect moving mechanism under the table, covered with thin carbon fiber. This sandwich construction is very rigid and lightweight, so the table top can handle relatively heavy load comparing to its cantilevered structure which is unavoidable as long as cooperate with C-arm radiography. To verify the design results finite element static analysis and experimental tests have been done. According to the verification the results well satisfy certification guide lines as a medical device.

  • PDF

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.

Rupture of the Trachea and the Esophagus Following Blunt Trauma: A Report of a Case (Blunt Trauma 에 의한 기관-식도 파열의 치험 1례)

  • 정윤채
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.119-124
    • /
    • 1975
  • This is a case report of the rupture of the trachea and the esophagus following external blunt trauma without any associated injury. A 7 year old male patient was brought to the emergency room. Hanyang University Hospital, on 23 Jul, 1974 while he played under the pile of pingpong table A table was fall down over the patient accidentally. The patient was injured by the table and found lying in unconsciousness on the ground.There was subcutaneous emphysema on his anterior chest and neck. A contusion on the upper part of the sternum was noted. The breathing sound were diminished over the left side of the chest. Ronchi were heard over the right lung field. This patient was suffered from vomiting, dypsnea, and irritable mental state after this accident. On the chest roentgenogram in A-P view, hyperlucency at the mediastinum and parapericardiac area suggested the pneumomediastinum. On the next day, a diagnosis of the tracheal and esophageal rupture was confirmed by the esophagogram with Lipiodol swallowing. A right thoracotomy was performed and ruptured orifice of the trachea and the esophagus were closed with interrupted sutures. Postoperative course was uneventful and primary closure of the rupture of the trachea and the esophagus were succeeded.

  • PDF

Restoration of Upper Anterior Dentition using Customized Anterior Guide Table (Customized Anterior Guide Table을 이용한 상악 전치부 수복증례)

  • Oh, Woo-Shik;Jeong, Seung-Mi;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2003
  • When making crown and bridges on anterior regions, many practitioners consider the esthetics the most. For this reason functional aspect are not considered as much as the esthetics. If the occlusion on the anterior region are not formed correctly, movement of the temporomandibular joint can be disturbed and excessive stress can be occur that pathologic condition can be under lied. On this case presentation will show the importance of the anterior guidance and suggest the appropriate protocol of using customized anterior guide table. A 45years old male had to remake both of the upper central and lateral PFM because of the porcelain fracture. The new PFM crowns were made conventional methods without considering the anterior guidance. After the temporary setting, the patient complained of discomfort and short looking upper anteriors. To solve these problems we had to restore the palatal contour and length of the new crowns by making customized anterior guide table using temporary crowns that contains patient's old anterior guidance. This procedure which is copying the pt's comfortable anterior guidance to the final prosthesis made them to be esthetic and patients to feel comfortable.

Full mouth rehabilitation in edentulous patient with unstable mandibular position using flat table treatment dentures and CAD-CAM technology (치료의치와 CAD-CAM 기술을 이용한 불안정한 하악위를 가진 완전 무치악 환자의 치료 증례)

  • Kim, Yuyeon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.330-338
    • /
    • 2022
  • For edentulous patients with unstable mandibular movements and abnormal facial features due to condylar fractures and morphological abnormalities, it is important to find a stable mandibular position. In this case, the patient's facial improvement, mandibular movement stability, and denture stability were improved by using flat table treatment dentures. In addition, computer-aided design/manufacturing (CAD-CAM) technology was used in denture fabrication to maintain the vertical dimension and lip support of flat table treatment dentures, we report good results in improving the patient's discomfort.

Development of An Intelligent Tilt Table for Paralytic Patients (편마비 환자를 위한 틸트 테이블 구동장치 개발)

  • Kim, S.H.;Cho, J.M.;Nam, T.W.;Lim, J.H.;Pack, S.I.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.260-266
    • /
    • 2006
  • Due to damaged vertebrae nerves, serious disease and aging, patients who have to lie down for long period of time need to exercise to maintain up-right standing position and recover their paralytic leg. This study describes a development of an intellectual tilt table which can provide a patient with rehabilitating condition. This can be possible by measuring and displaying the hee bent angle and pressure for each foot during exercise in real time. It is expected that the patient's exercising effect can increase by monitoring these two values during exercise.

A study on the database structure of medical records - Focusing on Yakazudōmei's medical records - (의안(醫案)의 데이터베이스 구조화 연구 - 시수도명의 의안을 중심으로 -)

  • Kim, Sung-Won;Kim, Ki-Wook;Lee, Byung-Wook
    • Herbal Formula Science
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2017
  • Objectives : The contents of the literature associated with the medical records were entered into the database. We want to find the structure and search methods for efficient utilization of the database. Methods : The contents were entered into the database using the 'Access 2014 of the MS'. The Query Sentences were created and utilized for a search. Results : We could find information about the prescriptions, medical records and patients by the herbs and symptom combinations using the single table named 'Integrated Knowledge' and queries. Integrated Knowledge is a table that gathered patient information, prescription information and symptom information together. Conclusions : If you store patient, prescription and symptom information on a single table, you could search and use the results by various combinations of the various elements included in the table. These results could help curing patients on the basis of evidence-based treatment at the clinics.

Seoul Bochun Medical Clinic Examined Patient Statistical Data (경성보춘의원치료환자통계기록(京城普春醫院治療患者統計記錄) 고찰(考察))

  • Cha, Wung-Seok;Lee, Jeong-Hwa;Ahn, Sang-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.53-67
    • /
    • 2007
  • Seoul Bochun Medical Clinic Examined Patient Table' is a statistical data that Kim Young-Boon [1882-1974] put together himself. A total of 59353 cases from 1914 to 1935 were classified according to year and month of examination, and gender. Of the cases 26497 (${\fallingdotseq}$45%) were women and the remaining 32856 (${\fallingdotseq}$55%) cases were men. The most frequent disease examined was cold, followed by diarrhea and stomachache. Of the 639 different kinds of diseases ever examined, 71 had occurred on more than 100 occasions. The percentage that these 71 diseases occupies is an overwhelming 88.75%.

  • PDF

Pressure on Sacrum and Buttock according to Tilt Table Inclination (기립경사대 각도 증가에 따른 천골과 둔부 압력 변화)

  • Yuk, Goon-Chang
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: Although use of a tilt table is recommended in clinical practice, there are no published guidelines regarding pressure and inclination for tilt table use. The aim of the current study was to assess the changes of pressure on sacrum and buttock according to different inclination of the tilt table in healthy subjects. Methods: Thirty two healthy subjects participated in this study. Subjects were positioned supine on the tilt table and safety straps were secured across the chest, pelvic, and knee with sufficient tension to prevent the subjects from falling. Pressure and peak pressure of sacrum and buttock were measured using pressure mapping system with the tilt table standing at $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$, and $85^{\circ}$ inclination. Results: A significant decrease in the pressure of sacrum and buttock was achieved by increasing tilt table inclination (p<0.05): $0^{\circ}{\sim}15^{\circ}$ (8.16%), $15^{\circ}{\sim}30^{\circ}$ (8.02%), $30^{\circ}{\sim}45^{\circ}$ (11.61%), $45^{\circ}{\sim}60^{\circ}$ (16.18%), $60^{\circ}{\sim}75^{\circ}$ (16%), and $75^{\circ}{\sim}85^{\circ}$ (11.48%). A significant decrease in the peak pressure was achieved by increasing tilt table inclination (p<0.05): $30^{\circ}{\sim}45^{\circ}$ (9.91%), $45^{\circ}{\sim}60^{\circ}$ (19.24%), $60^{\circ}{\sim}75^{\circ}$ (19.93%), and $75^{\circ}{\sim}85^{\circ}$ (11.48%). No significant peak pressure change was observed in $0^{\circ}{\sim}15^{\circ}$, $15^{\circ}{\sim}30^{\circ}$ tilt table inclination (p>0.05). Conclusion: The results of this study showed that the pressure of sacrum and buttock were decreased according to increasing tilt table inclination in healthy subjects. Guidelines are needed in order to optimize patient safety and overall outcome for tilt table standing.

Design for Adhesive Carbon Heating Element X-ray Table with an Attached Heating Device (가열장치를 구비한 부착형 탄소발열체 X선 촬영대 고안)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.131-137
    • /
    • 2015
  • The purpose of this study is to warm up the conventional X-ray table by inventing and design for X-ray table with an attached heating device using less unloaded X-ray, CNT (carbon nano tube) heating element. Configuration of the product design for adhesive carbon heating element X-ray is composed of a conventional X-ray table, carbon nano tube planar heating element, an electrode line, flame resisting protective film, and the bottom film. Characteristics and advantages of this invented product is to provide gentle feeling, the sense of security, and eliminating anxiety to the patient wearing a patient gown and feel the cool air while receiving the test. Thus we are strongly recommend to use this device in the clinical situation.