• 제목/요약/키워드: Patient Monitoring System

검색결과 351건 처리시간 0.037초

마이크로컴퓨터를 이용한 환자감시장치의 개발 (The Development of Patient Monitoring System Using Microcomputer)

  • 김남현;박영철;유선국;김원기;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1280-1283
    • /
    • 1987
  • In this paper, we represent the development of microcomputer-based monitoring system which monitors patient's states-ECG, blood pressure, temperature and respiration. And since data acquisition and system controls are processed by microprocessor, this system improved the conventional method.

  • PDF

모델 베이스를 이용한 지능적 환자 감시 시스템의 설계 (A Design of Intelligent Patient Monitoring System using Model Base)

  • 김정욱;이석필;지승도;박상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.155-159
    • /
    • 1995
  • A design method that can easily construct intelligent patient monitoring systems is proposed. To achieve the design method, the SES/MB concept and a discrete event-based logic control formalism based on a set theory is introduced. In this control paradigm the controller expects to receive confirming sensor responses to its control commands within definite time windows determined by DEVS model of the system under control. Because data to be used for rule-based symbolic reasoning are to be abstracted, several AI methods are applied the processes. These methods are applied to intelligent patient monitoring systems so that they facilitate transformation from low level raw data to high level linguistic data. Model-based system representations have advantages of reusability, extensibility, flexsibility, independent testability and encapsulation.

  • PDF

순음 청력검사를 위한 원격진단 모니터링 시스템 (Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry)

  • 이강호;권영은;권오원
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

긴급환자 상황인식 및 분석을 위한 무선 ECG모니터링 시스템 (A Wireless ECG monitoring System for Application in Life Emergency Event Detection and Analysis)

  • ;이대석;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.421-425
    • /
    • 2006
  • 헬스케어와 무선 기술의 접목은 새로운 생체신호 모니터링 방법과 환자의 이동성 및 편의성을 제공하며 더 나은 방법으로 환자를 돌볼 수 있으며 이러한 장점으로 인해 최근 무선기술을 이용한 ECG 모니터링 및 계측 시스템이 개발되고 있다. 본 논문에서는 중요한 생체신호 중 가장 중요한 신호의 하나인 ECG 신호를 무선센서네트워크를 이용하여 무선으로 받은 후, 이를 서버컴퓨터에서 의사, 간호사 또는 환자의 보호자에게 진단의 기초자료로 제공할 수 있게 빈맥, 서맥, 동정지와 같은 비정상적인 ECG신호를 판단하는 ECG 모니터링 시스템을 구현하였다. 신체에서 계측된 ECG신호는 무선으로 서버와 RS-232로 연결된 베이스스테이션으로 전송되고 서버는 비정상적인 ECG 신호를 검사하여 저장 및 모니터링을 위해 PC/PDA로 데이터를 전송하며, 이러한 시스템을 활용하여 의료비 절감 및 더 편리한 의료서비스를 받을 수 있을 것으로 예상된다.

  • PDF

환자 맞춤형 전자기장 요실금 치료 시스템 개발 (Development of Individually Adapted Electromagnetic Therapy System in Incontinence)

  • 노시철;강규홍;이정석;민권식;권장우;최흥호
    • 전자공학회논문지SC
    • /
    • 제45권4호
    • /
    • pp.51-59
    • /
    • 2008
  • 요실금은 자신의 의지와는 무관하게 소변이 나오는 배뇨이상으로 삶의 질을 떨어뜨리는 대표적인 여성 질환이다. 치료방법 중 자기장을 이용한 치료는 자발적인 운동을 요구하지 않고, 수치심을 유발하지 않으며, 감염의 위험이 없기 때문에 가장 높은 발전 가능성을 가지고 있다. 하지만 획일화된 치료 프로토콜, 환자 의존적 치료방법, 환자 상태 평가 부재 등의 개선점도 갖고 있다. 이에 본 연구에서는 자기장을 이용하여 골반저근을 자극하고, 치료 중 환자의 상태 변화를 실시간 모니터링하는 시스템을 제안하였다. 또한, 환자의 요실금 정도에 따른 환자 맞춤형 자기장 치료 시스템을 제안하였다. 제안된 시스템은 자기장 발생장치, 냉각장치, 치료의자, 맥박 모니터링을 이용한 환자 감시 장치, 제어 소프트웨어로 구성되었으며, 시뮬레이션을 통한 고전력 시스템 설계 과정과 개발 후 성능 평가를 수행하였다. 제어 소프트웨어 개발을 통하여 사용의 편의성과 관리의 편의성을 확보하였으며, 환자의 증상별 치료 프로토콜을 적용하였다. 본 연구를 통하여 개발된 환자 모니터링을 포함한 환자 맞춤형 자기장 치료 시스템은 자기장 치료에서 발생할 수 있는 위험성을 줄이고, 환자의 증상에 맞게 패턴화된 치료법을 제시함으로써 요실금 자기장 치료의 효율성을 높일 수 있고, 전/후 치료를 통하여 환자에게 보다 접근된 치료법이라고 판단되었다. 이러한 결과는 요실금 환자들에게 보다 안전하고 체계적인 치료법을 제공하며, 요실금 자기장 치료 방법의 다양한 연구를 유도할 수 있을 것으로 사료되었다.

휴대용 심전도 모니터링 계측 시스템 개발에 관한 연구 (Development of an Ambulatory Wearable System for Continuous Patient Monitoring)

  • 박찬원;전찬민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.920-923
    • /
    • 2003
  • An wearable electrocardiogram (ECG) monitoring system is a widely used non-invasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we have a portable ECG monitoring system with conductive fiber which was characterized by the small-size and the low power consumption. The system consists of conductive fibers, one-chip microcontroller, ECG preprocessing circuit, and monitoring software to be able to record and analyze in PC. ECG preprocessing circuit is made of pre-amplifier with gain of 10, band-pass filter with bandwidth of 0.5-120Hz and 2.5V offset circuit for A/D conversion. ECG signals obtained by sensor are included with corrupted noises such as a baseline wandering, 60 Hz power noise and interference noise by body movement. For cancellation corrupted noises in signals obtained by conductive fiber, we used the wavelet decomposition of wavelet transforms in MATLAB toolbox.

  • PDF

류머티스 환자 이력 데이터에 기반한 환자 플로우 모니터링 시스템 (Patient Flow Monitoring System based on Rheumatic Patient History Data)

  • 김준우;이상철;박상찬
    • 한국콘텐츠학회논문지
    • /
    • 제14권10호
    • /
    • pp.10-19
    • /
    • 2014
  • 최근 병원에서 수집되는 데이터를 전자적으로 저장, 관리 및 공유하기 위하여 병원정보시스템이 널리 활용되고 있다. 이러한 시스템들은 현대 병원들의 업무 효율성 제고에 크게 기여해왔으나, 건강관리 서비스 제공자들의 의사 결정을 지원하기 위해서는 수집된 환자 관련 데이터를 적절히 가공하고 재사용하는 것이 필요하다. 특히, 본 논문은 만성 질환과 관련된 외래진료과 운영관리를 위한 환자 플로우 모니터링을 제안하고, 이와 관련된 사항들에 대해 토의하고자 한다. 제안하는 시스템은 환자 이력 데이터에 프로세스 마이닝 기법을 적용하여 추출한 표준 프로세스 모형 및 여러 가지 평가 지표들을 시각화하며, 이를 통해 관리자들은 외래진료과의 운영을 평가하고 개선할 수 있다. 본 논문에서는 환자 플로우 모니터링 시스템을 류머티스 진료과에 적용하였으며, 아이패드 기기에 최적화된 프로토타입 시스템을 예시로 보이고자 한다.

헬스 케어를 위한 무선 모니터링 시스템 구현 (An Implementation of Wireless Monitoring System for Health Care)

  • 엄상희;남재현;장용훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.67-71
    • /
    • 2007
  • 최근 고령 인구의 증가에 따른 헬스 케어 수요가 증가하고 있고 환자뿐만 아니라 일반인들에게서도 헬스 케어 모니터링에 대한 요구가 급증하고 있다. 또한 의료 서비스를 제공받으려는 대상자의 불편을 최소화하고, 지속적인 모니터링을 통한 헬스 케어가 가능할 수 있는 의료 기술과 의료 정보서비스에 대한 수요도 늘어나고 있는 추세이다 본 논문에서는 헬스 케어를 위한 무선 생체 신호 모니터링 시스템을 구현하였다. 구현된 시스템은 생세 신호 측정부와 무선 통신부로 구성된 센서 노드(sensor node)와 원격 시스템의 모니터링 프로그램으로 구성된다. 센서 노드에서는 심전도, 혈압, 맥파, 동맥혈산소포화도, 심박수를 측정할 수 있고 블루투스 기술을 이용하여 무선 전송을 하여 모니터링 시스템에서 실시간 무선 모니터링이 가능하도록 구현하였다.

  • PDF

헬스 케어를 위한 무선 모니터링 시스템 구현 (An Implementation of Wireless Monitoring System for Health Care)

  • 엄상희;장용훈
    • 한국정보통신학회논문지
    • /
    • 제12권8호
    • /
    • pp.1401-1407
    • /
    • 2008
  • 최근 고령 인구의 증가에 따른 헬스 케어 수요가 증가하고 있고 환자뿐만 아니라 일반인들에게서도 헬스 케어 모니터링에 대한 요구가 급증하고 있다. 또한 의료 서비스를 제공받으려는 대상자의 불편을 최소화하고, 지속적인 모니터링을 통한 헬스 케어가 가능할 수 있는 의료 기술과 의료 정보 서비스에 대한 수요도 늘어나고 있는 추세이다. 본 논문에서는 헬스 케어를 위한 무선 생체신호 모니터링 시스템을 구현하였다. 구현된 시스템은 생체신호 측 정부와 무선 통신부로 구성된 센서 노드(sensor node)와 원격 시스템의 모니터링 프로그램으로 구성된다. 센서 노드에서는 심전도, 혈압, 맥파, 동맥혈산소포화도, 심박수를 측정할 수 있고 블루투스 기술을 이용하여 무선 전송을 하여 모니터링 시스템에서 실시간 무선 모니터링이 가능하도록 구현하였다.

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF