• Title/Summary/Keyword: Patient Care Bed

Search Result 119, Processing Time 0.021 seconds

A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit (중환자실 병상주변공간의 면적과 간격에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

Use of Single Bedrooms versus Multiple Bedrooms: Selection Factors and Comparison of Patient Satisfaction (1인실과 다인실 입원 병상 이용에 관한 병상 선택 요인과 환자 만족도 분석)

  • Lee, Geun-Chan
    • Korea Journal of Hospital Management
    • /
    • v.26 no.3
    • /
    • pp.68-83
    • /
    • 2021
  • Background: It is widely acknowledged that single bedrooms have many potential advantages compared to multiple bedrooms. However, Korea has a reimbursement system that patients have to pay the additional fee if they will use single bedroom or pay-bed (1-3 bedroom). There is little research on patients' bed selection and relationship between patient satisfaction and bed type in the Korean setting. Methods: Using the 2017 Korea Health Panel (KHP) Survey data, we modified bed type by two dichotomous variables: single bedroom vs. multiple bedroom (2+ bedrooms) and pay-bed (1-3 bedroom) vs. reimbursed bed (4+ bedroom). Multivariate logistic regression is performed to determine the factors affecting the patient's choice of room types. Multivariate regression analysis was conducted to examine how hospital room types are affecting patient satisfaction. Results: Single room and pay-bed (1-3 bedroom) use was influenced by patient age (19- years old), male, a person at work, hospitalizing in a clinic, and birth. After controlling variables of the behavioral model of medical utilization, the association between patient satisfaction and use of single bedroom & pay-bed (1-3 bedroom). Cause of hospitalization, major treatment, and recognition of unnecessary care are statistically significant variables on patient satisfaction. Conclusion: Although the single room is about the standard for newly built hospitals in western countries, it remains unclear that single room or pay-bed (1-3 bedroom) has positive effects on patient's outcomes and satisfaction. In this empirical study, the difference in patient satisfaction by bedroom type was not noticeable. In terms of bed management by hospital staff, securing patient credibility in hospital care is an important task. Patients' perception of whether medical staffs have encouraged unnecessary treatment or tests has a significant impact on patient's satisfaction.

The Patient Days and Medical Care Benefits of Finger-Amputated Patients due to Industrial Accident by Hospital and Patient Characteristics (병원 및 환자특성에 따른 수지절단 산업재해환자의 요양기간과 진료비)

  • Kam, Sin
    • Health Policy and Management
    • /
    • v.7 no.2
    • /
    • pp.1-18
    • /
    • 1997
  • This study was conducted to analyze patient days and medical care benefits of finger-amputated patients due to industrial accident. The 161 personal data on medical care for finger-amputated patients due to industrial accident(88 in 1994, 73 in 1995) of Regional Labor Office and hospital characteristics were analyzed. The major results of this study were as follows : According to stepwise multiple regression analysis of patient days, number of amputated finger, location of hospital, bed capacity of hospital, presence of plastic surgery in hospital, number of orthopedic specialist per 100 beds, sick leave benefits per day were the major significant variables in order. In stepwise multiple regression analysis with medical care benefits as a dependent variable, presence of plastic surgery in hospital, number of orthopedic specialist per 100 beds, number of amputated finger, sick leave benefits per day, age, bed capacity of hospital were the major significant variables in order. The minimum optimal size with the lowest medical care benefits was a hospital with 300 beds. This shows that the economy of scale is also applicable for hospital industry. In summary, presence of plastic surgery in hospital, number of orthopedic specialist per 100 beds, number of amputated finger, sick leave benefits per day, bed capacity of hospital were the major significant variables in both patient days and medical care benefits.

  • PDF

Relationship Between Supply Factors of Medical Care and Use of Bed (의료의 공급량과 병상이용량과의 관계에 관한 국제비교연구)

  • 정형선
    • Health Policy and Management
    • /
    • v.5 no.2
    • /
    • pp.18-34
    • /
    • 1995
  • To clarify the relationship between the medical supply(medical persons and goods) and the use of bed, the author has made comparison among OECD 24 countries. Per Capita Bed-days can be divided into Average Length of Stay and Admission Rate, and these three variables were regressed upon both In-patient Care Beds of all medical institutions including acute somatic, psychiatric, special, nursing homes and other long-term care and Share of Total Health Employment in Total Employment. The result of regression analysis shows a statistically significant positive relationship between In-patient Care Beds and Average Length of Stay, and negative relationship between Share of Total Health Employment and Admission Rate. In addition to Ordinary Least Square(OLS) estimation, amended Bounded Influence Estimation(BIE) was also made to adjust the influence of outliers. Japan shows a very large number of In-patient Care Beds and a very low Share of Total Health Employment, and this medical situation is judged to have close relation to her long Average Length of Stay and low Admission Rate.

  • PDF

A Study on the Development of Predictive Model for Patient Visibility in Korean Intensive Care Units (ICUs) - Focused on "Corridor or Continental" type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.3
    • /
    • pp.27-34
    • /
    • 2016
  • Purpose: The purpose of this paper is to develop a predictive model for patient visibility in Korean ICUs (corridor or continental type). Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage and departmental gross square meter per patient bed) were calculated by using AutoCAD and MS Excel programs. Regression analysis was conducted for visibility as dependant variable with independent variables of patient area percentage, staff area percentage as well as departmental gross square meter per bed by using IBM SPSS. Results: (1) Average patient visibility and percentage of patient area in ICU shows a strong negative correlation ($r^2$=0.66), p=0.01. (2) Patient visibility in Korean ICU (corridor or continental type) can be calculated as below with the given conditions: Y= $-1.449(X)+124.3{\pm}6$, Y is the total visibility of the ICU (corridor or continental type) and X is the percentage of patient area in the unit. Conditions:1. Given that the unit has a mixed programme of open bed and closed patient rooms and 2. The unit have a minimum of 20% patient rooms. Implications: This study may contribute to the visibility analysis of existing and future ICU design (corridor or continental type) in Korea to achieve maximum patient visibility and reduced patient mortality.

Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness (자세안정성 원리에 기반한 환자이동기술 개발 및 효과검정)

  • Ma, Ryewon;Jung, Dukyoo
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.1
    • /
    • pp.39-49
    • /
    • 2016
  • Purpose: This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. Methods: Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. Results: Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. Discussion: Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

Remote Care Using Medical Bed System Equipped With Body Pressure Sensors (체압 센서를 이용한 의료용 침대의 원격 케어)

  • Jaehyeok Jeung;Sanghyun Bok;Junhee Lim;Bokyung Oh;Youngdae Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.619-625
    • /
    • 2023
  • In this paper, the remote care of medical beds with multiple body pressure sensors is described. Falling is one of the factors that seriously threaten the safety of patients and harm their health. In this study, a new bed was developed to overcome this. The bed system consists of a keyboard that can operate, a keyboard controller that manages the movement of the keyboard, a sensor that measures body pressure, a sensor controller that transmits and receives sensor values, a main controller that checks it and operates automatically or manually according to the algorithm, and a server that oversees all these information. The bed system checks the patient's location through a sensor and wirelessly alerts the server through the main controller when the patient determines that there is a risk of falling, so that the nurse or nurse can recognize the patient's dangerous condition. The server may receive state data transmitted from the wired/wireless terminal to monitor whether the bed system is operating normally. The controller of the keyboard operates a keyboard-type mechanism and automatically controls the prevention of bedsores connected by body pressure sensors to physically separate the area to which the patient's pressure is applied to prevent bedsores. The main controller checks the presence of the patient's bed and transmits it to the server. In conclusion, the proposed system can smart monitor the user's state and perform remote care.

Bed Side Monitoring System using Occupancy Sensor and Doppler Radar (Occupancy 센서와 도플러 Radar를 이용한 침상 모니터링 시스템)

  • Kang, Byung Wuk;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.3
    • /
    • pp.382-390
    • /
    • 2018
  • A major accident occurring on the bed is falls that occur during at times when the care of nurses or protectors is inadequate, which is fatal to patients or the elderly. In particular, Enuresis or sleepiness caused by sleep apnea increases the risk of falls. Therefore, it is very important to detect falls and sleep apnea of patients without infringing privacy in the bed to patient's safety and accident prevention. In this paper, we reviewed the technologies developed for bed monitoring and implemented a non-intrusive monitoring system. The Occupancy Sensor allows the temperature of the bed and surrounding area to be extracted to enable track of the patient's motion. The Doppler Radar detects the patient's movements at normal times and the respiration state when patients have no movement during sleeping. It is specially designed for real-time monitoring of falling and respiration during sleeping through contactless multi-sensing while solving patient's privacy problems.

The Nurse Staffing in Intensive Care Units based on Nursing Care Needs: A Multicenter Study (중환자 간호요구도에 근거한 중환자실 간호사 배치수준 산정 : 다기관 연구)

  • Park, Miok;Yang, Eunjin;Lee, Mimi;Cho, Sung-Hyun;Shim, Miyoung;Lee, Soon Haeng
    • Journal of Korean Critical Care Nursing
    • /
    • v.14 no.2
    • /
    • pp.1-11
    • /
    • 2021
  • Purpose : The aim of this study was to propose appropriate nurse staffing of adult intensive care units considering patients' nursing care needs according to the Workload Management System for Critical Care Nurses (WMSCN). Methods : In a cross-sectional survey conducted in September 2017, 1,786 patients' WMSCN scores, surveys from 2,145 nurses, and administrative data from 118 units in 41 hospitals were analyzed. The means (standard deviations) of the aforementioned scores and nursing hours per patient day were presented. Nurse-to-patient ratios and nurse-to bed ratios for staffing to meet patients' nursing care needs were calculated. Results : The mean WMSCN scores were 109.50±17.17 in tertiary hospitals and 96.38±19.26 in general hospitals. Nursing hours per patient day were 12.47±2.80 in tertiary hospitals and 11.01±2.45 in general hospitals. Nursing hours per patient day correlated with WMSCN scores. Nurse-to-bed ratios required for the provision of ICU nursing care ranged from 1: 0.36 to 1: 0.48. Conclusion : Our findings provide evidence that current ICU nurse staffing is insufficient for meeting patients' nursing care needs. We suggest adjusting the legal standards for adequate nurse staffing considering these needs.