• 제목/요약/키워드: Paticle image Velocimetry

검색결과 5건 처리시간 0.018초

PIV 계측에 의한 $180^{\circ}$곡관 출구에 연결된 직관에서 층류정상유동의 운동에너지 (Kinetic energy of Laminar Steady flows in the Exit Reguon Connected to the straight Square-sectionnal $180^{\circ}$ curved Duct by using PIV)

  • 이종구;이홍구;손현철;이행남;박길문
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.521-524
    • /
    • 2002
  • In the present study, kinetic energy of laminar steady flow in the exit region connected to the square-sectional $180^{\circ}$curved duct was investigated experimentally. The experimental study for air flows was conducted to measure kinetic energy distributions by using the Particle Image Velocimetry(PIV) system with the data acquisition and processing system of Cactus 2000 software. The results obtained from experimental studies are summarized as follows : (1) The critical Reynolds number for a change from laminar steady flow to transitional steadt flow was about 1910, in the 50 region of dimensionless axial position (x/Dh) whirh was considered as a fully developed flow region. (2) Maximum kinetic energy of laminar steady flow was gradually increased as the Reynolds number increased.

  • PDF

단일공급 스월 혼합챔버 내의 와류유동에 대한 실험적 연구 (Experimental Investigation on the Vortical Flows in a Single-Entry Swirl Mixing Chamber)

  • 김형민;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.445-450
    • /
    • 2011
  • 금속분말을 연소시키기 위한 스월 연소기 설계의 기초단계로써 단일 접선 공급유로를 갖는 스월 혼합챔버를 제작하고 Paticle Image Velocimetry(PIV)를 사용하여 스월 혼합챔버의 내부 유동장 측정실험을 수행하였다. 상온의 공기를 작동유체로 사용하였으며 접선 공급유량이 증가하는 경우의 스월 혼합 챔버 내 축방향 및 접선방향 성분 속도를 획득하였다. 측정된 유동장을 바탕으로 스월유동과 역압력 구배로 인해 발생하는 외부 유입유동간의 혼합특성을 평가 하였다.

  • PDF

표면영상유속계(SIV)를 이용한 현장유량측정 (Field Measurement of Water Discharge by using Surface Image Velocimetry)

  • 김서준;주용우;류권규;윤병만
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.739-742
    • /
    • 2008
  • 표면영상유속계(SIV)는 기존의 입자영상유속계(PIV)의 원리를 이용하여 하천의 표면유속을 측정하는 방법이다. 본 연구에서는 경제적이고 효율적인 유속측정 기법인 SIV 기법을 이용하여 국내 3개 하천에 대하여 현장 유량측정에 적용하였다. 현장 영상분석은 다중카메라 방식을 이용하였고 영상분석과정에 필요한 참조점과 횡단면 자료는 측량을 통하여 획득하였다. SIV로 측정된 유속을 검증하는 수로 실험의 결과, 평균오차 10% 이내의 정확도를 보여 정확한 유속측정이 가능함을 확인하였다. 그러나, 실제 하천에의 적용에서는 저수위시와 악천후시에 대해서는 20 % 이내의 오차를 보이는 것으로 나타났다. 향후 SIV 기법의 문제점들을 해결한다면 언제 어디서나 효율적이고 경제적인 유량측정을 할 수 있을 것이다. 그리고 이를 활용하여 실시간 하천정보시스템으로 발전시킴으로써 하천 관리에 큰 도움이 될 것이라 판단된다.

  • PDF

PIV/LIF기법에 의한 교반혼합기 내의 속도장과 농도장 동시 측정 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Technique)

  • 정은호;윤상열;김경천
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.504-510
    • /
    • 2003
  • Simultaneous measurements of turbulent velocity and concentration field in a stirred mixer tank are carried out by using PIV/LIF technique. Instantaneous velocity fields are measured with a 1K$\times$1K CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

PIV/LIF에 의한 교반혼합기 유동의 난류 속도/농도장 측정 및 POD해석 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Techniqueut and POD Analysis)

  • 정은호;윤상열;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Simultaneous measurement of turbulent velocity and concentration field in a stirred mixer tank is carried out by using PIV/LIF technique. Instantaneous velocity fields are measured by a $1K\times1K$ CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

  • PDF