• 제목/요약/키워드: Pathogenic E. coli O-157

검색결과 130건 처리시간 0.022초

양상추에 오염된 병원성 미생물에 대한 Chlorine Dioxide 및 상업적 Chlorine 살균소독제의 저해효과 평가 (Inhibitory Effects of Chlorine Dioxide and a Commercial Chlorine Sanitizer Against Foodborne Pathogens on Lettuce)

  • 최미란;이선영
    • 한국식품조리과학회지
    • /
    • 제24권4호
    • /
    • pp.445-451
    • /
    • 2008
  • This study compared the effects of chlorine dioxide and a commercial chlorine sanitizer for inhibiting foodborne pathogens, including Salmonella enterica serovar Typhimurium, Listeria monocytogenes, and Escherichia coli O157 : H7, on lettuce leaves. The lettuce samples were inoculated with each cocktail of the three strains, and were then treated with chemical sanitizers [distilled water, 100 ppm commercial chlorine and 50 ppm, 100 ppm, 200 ppm chlorine dioxide ($ClO_2$)] for 1 min, 5 min, and 10 min at room temperature($22{\pm}2^{\circ}C$). Following inoculation of the leaves, initial populations of E. coli O157:H7, L. monocytogenes, and S. Typhimurium were approximately 5.54, 4.47, and 5.12 log CFU/g, respectively these levels were not significantly reduced by the treatment with water,whereas the 100 ppm commercial chlorine sanitizer treatment and $ClO_2$ (at all tested concentrations) were effective at reducing levels of all three pathogens. The treatment of 200 ppm $ClO_2$ for 10 min was most effective at inhibiting the three pathogens, and reduction levels of E. coli O157 : H7, L. monocytogenes, and S. Typhimurium were 2.28, 1.95, 1.76 log, respectively. The inhibitory effect of $ClO_2$ increased with increasing treatment concentration of $ClO_2$, but there was no significant difference by the treatment times. When chemically injured cells of E. coli O157 : H7 and L. monocytogenes and S. Typhimurium were examined by SPRAB and selective overlay methods, respectively, it was observed that the commercial chlorine sanitizer generated greater numbers of injured L. monocytogenes than the $ClO_2$ treatment. From the overall results, $ClO_2$ was more effective at inhibiting pathogenic bacteria compared to the commercial chlorine sanitizer therefore, it has potential to be utilized as an alternative sanitizer to increase the microbial safety of fresh produce.

PCR Kit와 선택배지를 이용한 계란의 병원성세균 검출 비교 평가 (Comparison of a PCR Kit and a Selective Medium to Detect Pathogenic Bacteria in Eggs)

  • 김동호;윤혜정;송현파;임상용;조민호;조철훈
    • 한국식품저장유통학회지
    • /
    • 제16권6호
    • /
    • pp.965-970
    • /
    • 2009
  • 유통중인 계란의병원성균 오염상태를 시판되는 multiplex polymerase chain reaction (mPCR) kit로 검사한 결과, 총 90개의 검사시료 가운데 한 가지 이상의 미생물이 검출된 계란시료는 30개로, 검사시료의 미생물 오염도는 약 33.3% 수준이었다. 미생물별 검출 빈도는 B. cereus가 17개 시료(18.9%)에서 검출되어 가장 높은 빈도를 보였으며 Y. enterocolitica는 16개(17.8%), L. monocytogenes 15개(16.7%), St. aureus 12개(13.3%), E. coli O157:H7 4개(4.4%)의 검출빈도를 보였다. 한편, 선택배지를 이용한 viable cell count 방법에서는 27개의 시료에서 미생물이 검출되어 검사시료의 미생물 오염도는 약 30.0% 수준이였으며, 미생물별 검출 빈도는 B. cereus가 17개 시료(18.9%)에서 14개(15.6%) 시료로, Y. enterocolitica는 16개(17.8%)에서 12개(13.3%)로, L. monocytogenes는 15개(16.7%)에서 13개(14.4%)로, St. aureus는 12개(13.3%)에서 10개(11.1%)로 감소하였으며, E. coli O157:H7은 두 가지 검출방법간의 차이가 나타나지 않았다. 검출 대상 미생물 9종 가운데 Campylobacter jejuni, Vibrio parahaemolyticus, Salmonella spp., 및 Shigella spp.는 두 방법 모두에서 검출되지 않았다. 이상의 결과에서 살펴본 바와 같이 PCR을 이용한 병원성 미생물의 검출 방법은 viable cell count 방법보다 감도가 높음을 알 수 있었다.

이산화염소수와 전해수를 이용한 식중독균의 살균효과 (Bactericidal Effects of Food-borne Bacteria using Chlorine Dioxide and Electrolyzed Water)

  • 이혜린;김수진;방우석
    • 한국식품위생안전성학회지
    • /
    • 제37권4호
    • /
    • pp.232-237
    • /
    • 2022
  • 본 연구에서는 병원균인 Bacillus cereus, Staphylococcus aureus, Salmonella Typhimurium 그리고 Escherichia coli O157:H7을 이산화염소수와 전해수에 0분, 2분, 4분, 6분, 8분 및 10분간 반응시켜 이산화염소수와 전해수의 살균 효과를 확인하고, 그람 양성균(B. cereus, S. aureus)과 그람 음성균(S. Typhimurium, E. coli O157:H7)의 민감성 비교를 실시하였다. B. cereus, S. aureus, S. Typhimurium 그리고 E. coli O157:H7의 이산화염소수에서의 D값은 1.85±0.64, 2.06±0.85, 2.26±0.89 그리고 2.59±0.40분으로 나타났고 전해수의 경우 각각 2.13±0.32, 1.64±0.64, 1.71±0.32 그리고 1.86±0.36분으로 나타났다. 각 용액에 처리한 10분 간 모든 균주에서 꾸준한 감소 추세를 나타내었으며 각 용액에서 각 균주의 D값은 서로 유의적인 차이는 보이지 않았다 (P>0.05). 이산화염소수와 전해수의 살균력을 비교한 결과 D값은 유의적인 차이가 나타나지 않았으나, pH와 유효염소농도 모두 이산화염소가 전해수보다 낮은 값을 보였다. 살균·소독을 실시할 대상의 pH에 대한 민감성과 같은 특성을 고려하여 최적의 살균제를 선택하고, 최적의 농도를 결정하여 식품 산업에 적용하기 위한 자료로 활용될 것으로 기대된다.

레토르트 곡물 두유 내 Bacillus cereus, Escherichia coli O157:H7, Listeria monocytogenes의 내열특성 (Thermal Resistance Characteristics of Bacillus cereus, Escherichia coli O157:H7, and Listeria monocytogenes in a Multi-grain Soy Milk Product)

  • 김남희;구재명;이민석
    • 한국식품과학회지
    • /
    • 제47권5호
    • /
    • pp.593-598
    • /
    • 2015
  • This study determined the thermal resistance of Bacillus cereus, Escherichia coli O157:H7, and Listeria monocytogenes in multi-grain soymilk and proposes processing conditions that meet the national standard for retort food products in Korea. D and z values were calculated from thermal inactivation kinetic curves after heating at 55, 60, and $65^{\circ}C$. The D value for B. cereus at $55^{\circ}C$ was the highest (22.8 min), followed by that for E. coli O157:H7 (18.8 min) and L. monocytogenes (17.6 min). At $60-65^{\circ}C$, the order was L. monocytogenes ($D_{60-65^{\circ}C}=3.4-0.9min$), E. coli O157:H7 (3.0-0.3 min), and B. cereus (1.2-0.3 min). The z values for these species were 5.2, 5.5, and $7.7^{\circ}C$, respectively. The Korean national standard for retort food products was achieved by thermal processing at $124{\pm}2^{\circ}C$ for 0.3-2.2 min. This study provides useful data for ensuring both the microbiological safety and product quality of multi-grain soymilk products.

병원성 미생물에 대한 다빈도 51종 한약처방의 항균 활성 연구 (Antimicrobial Activities of 51 Herbal Formulae on Pathogenic Microorganisms)

  • 이나리;신현규;하혜경;최순용
    • 대한한의학방제학회지
    • /
    • 제27권4호
    • /
    • pp.257-267
    • /
    • 2019
  • Objectives: The purpose of this study was to establish experimental evidence for the antimicrobial effects of 51 herbal formulae commonly used in traditional Korean medical institutions. Methods: The antimicrobial activities of herbal formulae were screened using the disc diffusion method against 10 pathogenic microorganisms (Bacillus cereus, Staphylococcus aureus, Listeria monocytogenes, Vibrio parahaemolyticus, Escherichia coli DH5α, E. coli O157, Salmonella enteritidis, Yersinia enterocolitica, Shigella flexneri, and Helicobacter pylori). Of the 51 herbal formulae, 13 herbal formulae with antimicrobial activity were selected and their dose-dependency were confirmed. Results: Nine herbal formulae, including Gyeji-tang, Dangguisu-san, Saengmaek-san, Samul-tang, Ssanghwa-tang, Socheongryong-tang, Yukmijihwang-tang, Jakyakgamcho-tang, and Paljung-san, presented antibacterial activity against B. cereus. The effects of Saengmaek-san and Paljung-san was sustained for 48 hr. On L. monocytogenes, Dangguisu-san and Hyangsapyeongwi-san showed antimicrobial activity, but only Hyangsapyeongwi-san maintained the activity for 48 hr. Thirteen herbal formulae such as Galgeun-tang, Gyeji-tang, Dangguisu-san, Mahwang-tang, Banhasasim-tang, Saengmaek-san, Socheongryong-tang, Yukmijihwang-tang, Jakyakgamcho-tang, Cheonwangbosim-dan, Palmijihwang-tang, Paljung-san, and Hwanglyeonhaedok-tang showed antimicrobial activity against V. parahaemolyticus, and the activity was maintained for 48 hr. The 51 herbal formulae did not show any antimicrobial activity against seven strains such as E. coli DH5α, E. coli O157, S. aureus, S. enteritidis, Y. enterocolitica, S. flexneri, and H. pylori. Conclusions: Nine, two, and thirteen herbal formulae showed antimicrobial activities against B. cereus, L. monocytogenes, and V. parahaemolyticus in a dose-dependent manner, respectively. The results of antimicrobial activity of 51 herbal formulae against 10 microorganisms might be used as the basis for new application of herbal formulae.

면역크로마토그래피를 이용한 E. coli O157: H7 신속검출 키트의 유효성 평가 (Evaluation of the Efficiency of E. coli O157: H7 Rapid Detection Kit using Immunochromatography)

  • 곽효선;이동하;문희숙;박종석;우건조;김창민
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.118-124
    • /
    • 2003
  • 식품으로부터 다양한 병원 미생물을 신속 검출하기 위하여 다양한 검출 원리를 이요한 키트들이 개발 시판되고 있다. 검사키트는 신속, 정확하고 간단하게 사용할 수 있으므로 검사기관이나 실험실 뿐 아니라 식품회사에서 QC 또는 QA를 수행하기 위하여 사용이 증가되고 있는 추세이다. 이에 본 연구에서는 E. coli 0157:H7의 단클론항체를 이용하여 면역크로마토글래피법에 의해 개발된 E. coli 0157:H7 검출 키트(Donga Co, Korea, D-kit)에 대한 검출감도 및 특이성을 확인하고 식품 시료에 적용 가능성을 평가하였다. 면역크로마토그래피법에 의하여 개발 시판되고 있는 Reveal E. coli 0157:H7 kit (Neogen Co., USA. R-kit)와 VIP EHEC kit(Biocontro Inc., USA. V-kit)를 비교 키트로 사용하였다. E. coli 0157:H7 표준균주를 사용하여 실시한 검출감도 확인시험 결과 R-kit 및 D-kit는 104/m/의 농도에서 양성으로 확인되었고 $10^3$/ml에서도 약한 양성 반응을 보였으나, V-lit는 $10^5$/ml농도로 검출감도가 낮았다. 또한, 배양액을 가열하여 kit에 적용하는 것이 가열하지 않은 경우보다 검출감도를 높일 수 있었다. E. coli 0157:H7 분리 22주, verotoxin 생성 E. coli 7주 E. coli 분리주 40주 중 3주를 제외한 모든 균에서 음성의 결과를 보여 특이성을 확인하였다. 세 키트에 위양성 반응을 보인 것은 E. coli 0157:H19, E. coli 0148:H18 및 Salmonella gallinarium으로 이들 혈청형과 0157:H7 사이에는 유사한 혈청학적 특성이 존재하는 것으로 추정되었다. 이상의 실험결과로 D-kit는 E. coli 0157:H7을 검출하는데 감도 및 특이성 면에서 기존 키트인 R-kit 및 V-kit와 같이 이용한 것으로 확인되었다.

오미자 에탄올 추출물에 의한 식품위해성 세균의 증식 억제 및 세포구조 변화 (Inhibition of Foodborne Pathogens and Spoilage Bacteria and Their Structural Changes by Ethanol Extract of Schizandra chinensis Baillon)

  • 김세령;김미라
    • 동아시아식생활학회지
    • /
    • 제22권1호
    • /
    • pp.109-119
    • /
    • 2012
  • 본 연구에서는 오미자 에탄올 추출물의 천연 항균제로서의 이용 가능성을 살펴보기 위하여 식품 위해성 세균에 대한 항균활성을 측정하였다. Paper disc diffusion test와 최소저해 농도(MIC) 측정에서는 오미자 에탄올 추출물이 Listeria monocytogenes, Bacillus cereus, Escherichia coli O157:H7에 대해 큰 생육저해환과 낮은 MIC를 나타내었다. Time-kill assay에서는 L. monocytogenes의 생육이 오미자 에탄올 추출물에 의해 가장 저해되는 것으로 나타났다. 또한 오미자 에탄올 추출물을 처리한 E. coli, E. coli O157:H7, Staphylococcus aureus, Pseudomonas aeruginosa에서는 ${\beta}$-galactosidase와 o-nitrophenyl-${\beta}$-D-galactoside가 높은 반응을 나타냄으로써 오미자 에탄올 추출물로 인해 세포막 손상이 유발됨을 유추할 수 있었다. 또한 E. coli, E. coli O157:H7, P. aeruginosa, Salmonella Typhimurium 등 그람음성균에서는 오미자 에탄올 추출물의 처리 농도가 높을수록 세포구성물의 유출과 세포 외막의 투과성이 증가하는 현상이 나타났다. 시차주사현미경(SEM)과 투과전자현미경(TEM)을 이용하여 관찰한 세포구조에서도 오미자 에탄올 추출물 처리 시 세포막의 부분적인 파괴와 세포 팽윤이 일어난 것을 확인할 수 있었다. 따라서 이들 결과는 오미자 에탄올 추출물이 식품위해성 세균에 대해 높은 항균 활성을 가지고 있으며, 천연 항균소재로서의 이용 가능성이 있음을 보여주었다.

전라북도 지역 농업용수의 미생물학적 특성 및 온도와 수질에 따른 농업용수의 병원성대장균 O157:H7 밀도 변화 (Microbiological Quality of Agricultural Water in Jeollabuk-do and the Population Changes of Pathogenic Escherichia Coli O157:H7 in Agricultural Water Depending on Temperature and Water Quality)

  • 황인준;함현희;박대수;채효빈;김세리;김황용;김현주;김원일
    • 한국환경농학회지
    • /
    • 제38권4호
    • /
    • pp.254-261
    • /
    • 2019
  • 농업용수는 채소류의 식중독세균 오염의 주요 경로 중 하나임에도 불구하고 우리나라에서는 농업용수의 미생물학적 안전성 대한 기초 자료가 부족한 실정이다. 본 연구에서는 전라북도에서 2018년 4월, 7월, 10월에 31지점에서 수집한 지표수 시료와 2018년 4월 7월에 20지점에서 수집한 지하수 시료의 위생지표세균 밀도를 조사하였다. 지표수에서는 평균적으로 대장균군이 2.7±0.55 log CFU/100 mL, 분원성대장균군 1.9±0.71 log CFU/100 mL, 대장균 1.4±0.58 log CFU/100 mL로 나타났고, 7월에 가장 높은 밀도를 보였다. 지하수의 경우 평균적으로 대장균군이 1.9±0.58 log CFU/100 mL, 분원성대장균군 1.4±0.37 log CFU/100 mL, 대장균 1.0±0.33 log CFU/100 mL로 나타났고 조사시기 간의 유의한 차이가 나타나지 않았다. 총질소량(T-N), 질산성질소(NO3-N) 등 유기물 함량이 높은 용수에서 E. coli O157:H7의 생존이 연장되는 것으로 나타났다. 물에서의 E. coli O157:H7 감소율은 25℃>35℃>5℃>15℃ 순으로 높게 나타났다. 이러한 결과는 전북 지역 농업용수의 미생물학적 오염도와 수질과 온도가 E. coli O157:H7의 생존에 미치는 영향을 보여준다. 이러한 결과는 농업용수의 미생물학적 오염도를 예측하고 미생물 제어 기술 개발의 기초자료로서 활용될 수 있다.

Combined Treatment with Low Concentrations of Aqueous and Gaseous Chlorine Dioxide Inactivates Escherichia coli O157:H7 and Salmonella Typhimurium Inoculated on Paprika

  • Kim, Hyun-Gyu;Song, Kyung Bin
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권3호
    • /
    • pp.492-499
    • /
    • 2017
  • Combined treatment with gaseous and aqueous chlorine dioxide ($ClO_2$) was performed to improve the microbiological safety and quality of paprika. A single treatment of 50 ppmv $ClO_2$ gas for 30 min decreased the populations of Escherichia coli O157:H7 and Salmonella Typhimurium by 2.33 and 2.91 log CFU/g, respectively. In addition, a single treatment of aqueous $ClO_2$ (50 ppm) for 5 min decreased these populations by 1.86 and 1.37, respectively. The most dramatic effects were achieved by combined treatment of 50 ppm aqueous and gaseous $ClO_2$ for 30 min, which decreased populations of E. coli O157:H7 and S. Typhimurium by 4.11 and 3.61 log CFU/g, respectively. With regard to the qualities of paprika, no adverse effects were elicited by the combined treatment. Thus, combined treatment with aqueous and gaseous $ClO_2$ is a suitable approach that can be used to improve the microbial safety and quality of paprika.

CRISPR/Cas 시스템 기술을 활용한 고위험성 식중독 세균 신속 검출을 위한 바이오센서 개발 (Development of Biosensors for Rapid Detection of Foodborne Pathogenic Bacteria using CRISPR/Cas)

  • 조선영;박종필
    • 한국식품위생안전성학회지
    • /
    • 제38권5호
    • /
    • pp.279-286
    • /
    • 2023
  • Rapid and accurate detection of pathogenic bacteria is crucial for various applications, including public health and food safety. However, existing bacteria detection techniques have several drawbacks as they are inconvenient and require time-consuming procedures and complex machinery. Recently, the precision and versatility of CRISPR/Cas system has been leveraged to design biosensors that offer a more efficient and accurate approach to bacterial detection compared to the existing techniques. Significant research has been focused on developing biosensors based on the CRISPR/Cas system which has shown promise in efficiently detecting pathogenic bacteria or virus. In this review, we present a biosensor based on the CRISPR/Cas system that has been specifically developed to overcome these limitations and detect different pathogenic bacteria effectively including Vibrio parahaemolyticus, Salmonella, E. coli O157:H7, and Listeria monocytogenes. This biosensor takes advantage of the CRISPR/Cas system's precision and versatility for more efficiently accurately detecting bacteria compared to the previous techniques. The biosensor has potential to enhance public health and ensure food safety as the biosensor's design can revolutionize method of detecting pathogenic bacteria. It provides a rapid and reliable method for identifying harmful bacteria and it can aid in early intervention and preventive measures, mitigating the risk of bacterial outbreaks and their associated consequences. Further research and development in this area will lead to development of even more advanced biosensors capable of detecting an even broader range of bacterial pathogens, thereby significantly benefiting various industries and helping in safeguard human health