• Title/Summary/Keyword: Path length

Search Result 784, Processing Time 0.023 seconds

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

  • Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.22.1-22.10
    • /
    • 2020
  • Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

Numerical Study of Flow Characteristics in Elementary Paths of Velocity-Control Trim (속도 제어형 트림의 단위 요소 유로의 유동특성에 관한 수치적 연구)

  • Kim, Dae-Kwon;Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.245-253
    • /
    • 2011
  • We investigate the flow characteristics of elementary-flow paths with $90^{\circ}$ bends; a velocity-control trim consists of such paths. For geometric similarity, the width and length of each path are selected, and the number of bends is 0, 4, or 8. The flow tests are conducted with the same flow-path elements. The numerical results are in good agreement with the experimental data. In elements without bends, the volume flow rate decreases with the length of the flow path, with a constant pressure drop between the inlet and the outlet. However, in flow paths with $90^{\circ}$ bends, it increases and then decreases with the length of the flow path. For a fixed number of $90^{\circ}$ bends, better pressure-drop characteristics are observed as the length of the flow path increases. For a fixed flow-path length, a flow-path element with more bends has a smoother pressure drop along the path.

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.296-299
    • /
    • 2013
  • A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves (밸브 하류에 설치된 건식 초음파유량계의 편차특성)

  • Lee, Dong-Keun;Cho, Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

Effects of a Standardized Critical Pathway for Gastrectomy Patients in a General Hospital (일개 종합병원의 위 절제 환자에 적용한 Critical Pathway의 효과)

  • Kim, Eun-Ok;Kwon, Soon-Man
    • Korea Journal of Hospital Management
    • /
    • v.9 no.3
    • /
    • pp.128-142
    • /
    • 2004
  • To evaluate the effects of critical pathway on the length of hospital stay, the cost and quality of care provided to gastrectomy patients in a tertiary care academic medical center. The basic research design is a retrospective case-control comparative study. 470 patients of gastrectomy were included in the study; 180 before pathway development (control), 163 right after pathway implementation (path group I) and 127 one year after pathway implementation (path groupII). 476 patients of modified radical mastectomy were also analyzed to examine whether the reduction of the length of hospital stay is from the hospital-wide trend or due to the critical pathway. Death after operation, ICU stay, unplanned re-operation, readmission after discharge, the length of hospital stay and cost were analyzed. 2-test, one-way ANOVA, Bonferroni and Turkey's test were used for statistical analysis. (1) There were no significant differences in patient clinical conditions and no sign of deterioration of quality from critical pathway. (2) The length of hospital stay was 13.0 days in control group, 12.2 days in path group I and 10.0 days (p<0.01) in path groupII. (3) The total costs during the hospital stay were reduced. However the cost per day was significantly increased from reduction of hospital stay (358,488won in control, 366,017won in path group I and 413,220won (p<0.01) in path groupII). Critical pathway reduced the length of hospital stay, total hospital costs and resource utilization without harming quality of patient care.

  • PDF

The Correlation of Agronomic Characters and Path Coefficient Analysis in Panax ginseng C.A. Meyer (고려인삼(Panax ginseng C.A. Meyer)의 년차간 형질상관 및 경로계수 분석)

  • Chung, Youl-Young;Chung, Chan-Moon;Choi, Kwang-Tae
    • Journal of Ginseng Research
    • /
    • v.19 no.2
    • /
    • pp.165-170
    • /
    • 1995
  • This study was carried out to investigate the correlation of agronomic characters, their path coefficients in 2, 3 and 4-year old ginseng plants, and to provide a useful information for ginseng breeding. Correlation coefficients between stem fen변h, number of leaves and number of Iraflets in 2-year age, and stem diameter and leaf length in 3-year age showed highly significant correlation with number of fruits and root weight in 4-year age. The path coefficient analysis indicated that stem length and number of leaflets might give indirect effects on root weight regardless of plant age. On the other hand, stem length and number of leaflets in 2-year age and, stem diameter and leaf length in 3-year age showed direct effects on root weight in 4-year old ginseng. These results may be used for selection of high-yielding ginseng plants. Key words Selection information, correlation and path coefficient analysis.

  • PDF

Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation

  • Adiguzel, Mehmet;Tufenkci, Pelin
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.41.1-41.7
    • /
    • 2018
  • Objectives: The purpose of the present study was to compare the mean preparation times and frequency with which Reciproc and Reciproc Blue instruments reached the full working length in mandibular molars, with or without glide path preparation. Materials and Methods: Previously untreated mesiobuccal and mesiolingual canals with completely formed apices were randomly divided into 6 groups (n = 50) depending on the usage of Reciproc (RC; VDW), Reciproc Blue (RC Blue; VDW), C-Pilot (CP; VDW), and R-Pilot (RP; VDW) files: RC, RC Blue, RC + C-Pilot (RC-CP), RC-Blue + C-Pilot (RC Blue-CP), RC+R-Pilot (RC-RP), and RC Blue + R-Pilot (RC Blue-RP). A glide path was prepared using the hand-operated C-Pilot or the machine-operated R-Pilot instruments, respectively. The ${\chi}^2$ test, analysis of variance, and the Tukey post hoc test were used for statistical comparisons. Results: No statistically significant differences were observed in the distribution of the frequency of reaching the full working length in the RC (94%), RC Blue (88%), RC-CP (94%), RC Blue-CP (90%), RC-RP (96%), and RC Blue-RP (92%) groups (p > 0.05). Conclusions: Preparation of a glide path did not have a significant effect on reaching the full working length using these systems.

A Study on a New Algorithm for K Shortest Detour Path Problem in a Directed Network (유방향의 복수 최단 우회 경로 새로운 해법 연구)

  • Chang, Byung-Man
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.11a
    • /
    • pp.60-66
    • /
    • 2006
  • This paper presents a new algorithm for the K shortest path problem in a directed network. After a shortest path is produced with Dijkstra algorithm, detouring paths through inward arcs to every vertex of the shortest path are generated. A length of a detouring path is the sum of both the length of the inward arc and the difference between the shortest distance from the origin to the head vertex and that to the tail vertex. K-1 shorter paths are selected among the detouring paths and put into the set of K paths. Then detouring paths through inward arcs to every vertex of the second shortest path are generated. If there is a shorter path than the current Kth path in the set, this path is placed in the set and the Kth path is removed from the set, and the paths in the set is rearranged in the ascending order of lengths. This procedure of generating the detouring paths and rearranging the set is repeated for the K-1 st path of the set. This algorithm can be applied to a problem of generating the detouring paths in the navigation system for ITS and also for vehicle routing problems.

  • PDF

A Study on Measurement Method of Optical Path Error in Arrayed Waveguide Grating Router (광도파로열 격자 라우터의 경로오차 측정 방법에 관한 연구)

  • Park, Jae-Sung;Chung, Young-Chul;Mun, Seong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2431-2433
    • /
    • 1999
  • Phase errors of arrayed waveguide degrade the performance of AWG router, especially for dense WDM system. So it is necessary to measure the phase error and to compensate. The analysis method of the interference signal from the low coherence interferometer to measure the path length difference phase error is studied. The interference signal generated assuming the intentional path length difference errors of 0.1$\sim$0.4${\mu}m$ are analyzed and the results show that the path length difference phase error of ${\Delta}L$ within ${\pm}14^{\circ}$ of sampling phase error can be accurately measured.

  • PDF

The Design of Piezo-driven mirror for the Path Length Control in a Ring Resonator (링 공명기의 경로치 제어를 위한 피에조 구동 거울의 설계)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2551-2556
    • /
    • 2009
  • The principal operation of a ring laser gyroscope depends on the phase difference for the counter-propagating waves within a closed path. The reflection mirrors mounted on the resonator block form the traveling waves. Thus, the dimension accuracy of resonator block influences the traveling path of beam. In order to maintain the stable optical beam path in the ring resonator, the piezo-driven moveable mirror is adopted for the path length control under the thermal expansion or mechanical strain of resonator block. This paper presents the mathematical description of the elastic behavior of piezo-driven mirror. This description can be applied for the concept design of piezo-driven mirror.