• Title/Summary/Keyword: Patellar tendon

Search Result 76, Processing Time 0.031 seconds

Transient Calcification of Autogenous Grafted Patellar Tendon in Anterior Cruciate Ligament Reconstruction - A Case Report - (슬관절 전방 십자 인대 재건술 후 발생한 이식 건의 일과성 석회화 - 증례 보고 -)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Kim, Jong Heon;Kim, Jae Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.30-34
    • /
    • 1999
  • We report the case of a 30-year-old man who was presented with transient calcification on the graft shortly after anterior cruciate ligament(ACL) reconstruction using a autogenous bone patellar tendon. The patient underwent ACL reconstruction with two incisional technique and six month later, calcific density was seen radiologically around the graft. On postoperative 13 months follow-up radiographic films, the calcific density disappeared. After two months of operation, Lachman and pivot shift test were negative and one millimeter side to side difference was detected in KT-1000 with 20 Ibs strength. But 6 months after the reconstruction, mild anterior instability was detected with the calcific density around the grafted tendon. However the anterior stability was recovered according to the disappearance of calcific density.

  • PDF

Comparison of ACL Reconstruction using Patellar tendon Autografts and Allografts (자가 슬개건과 동종 슬개건을 이용한 전십자인대의 재건의 비교)

  • Byun Ki-Yong;Rhee Kwang-Jin;Shin Hyun-Dae;Lee Won-Sok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.116-122
    • /
    • 1997
  • We have studied the results of reconstruction by freeze-dried patellar allografts or patellar autografts in ACL-deficient patients prospectively. From January 1995 to December 1995, we performed ACL reconstruction using an arthroscopic-assisted technique with patellar autografts in 21 patients and patellar allografts in 13 patients. Minimum followup time was 1 year(average 26 months). All patients were evaluated by using KT-2000 arthrometer and MRI as well as by physical examination. Final results were rated as satisfactory or unsatisfactory by using a modified Feagin knee scoring scale. Good or excellent were considered to have satisfactory results and fair or poor were considered to have unsatisfactory results. As measured by the KT-2000, 19 cases$(90.5\%)$ had a 5-mm or Jess side-to-side differential, a satisfactory results in autograft group, 2 cases of unsatisfactory results had joint instability. In allograft group, 10 cases$(76.9\%)$ had a 5-mm or less side-to-side differential, a satisfactory results, 3 cases of unsatisfactory results had joint instability including postoperative infection(1 case). In conclusion, the results of ACL reconstruction with autografts were better than those with allografts. The problem of allograft reconstruction were rehydration, aseptic control and improper mechanical tensioning. So, we thought that success of allograft reconstruction was depended on careful implant preparation including pretensioning technique.

  • PDF

Patellofemoral contact mechanics after transposition of tibial tuberosity in dogs

  • Park, Donghee;Kang, Jinsu;Kim, Namsoo;Heo, Suyoung
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.67.1-67.11
    • /
    • 2020
  • Background: Tibial tuberosity transposition (TTT) causes caudalization of the patellar ligament insertion in canine medial patellar luxation, which can lead to increases in patellofemoral contact pressure. Objectives: The purpose of this study is to confirm the effect of patellofemoral contact mechanics after craniolateral and caudolateral transposition of tibial tuberosity in normal canine hindlimbs. Methods: Craniolateral and caudolateral transposition of tibial tuberosity was performed in 5 specimens, respectively. The pressure was measured in the specimen before TTT, and then in the same specimen after TTT. In this process, data was obtained in 10 specimens. The measurement results were output as visualization data through the manufacturer's software and numerical data through spreadsheet. Based on these 2 data and the anatomical structure of the patellofemoral joint (PFJ) surface, whole measurement area was analysed by dividing into medial, lateral and central area. Results: In craniolateralization of tibial tuberosity, total, medial, central contact pressure was decreased and lateral contact pressure was not statistically changed lateral contact pressure than normal PFJ. In caudolateralization of tibial tuberosity, total, lateral contact pressure was increased and medial contact pressure was not statistically changed than normal PFJ. Although not statistically significant changed, central contact pressure in caudolateralization of tibial tuberosity was increased in all 5 specimens. Conclusions: These results imply that traditional TTT, prone to caudal shift of patellar tendon, can increase retropatellar pressure may lead to various complications and diseases of the stifle joint.

Inter-Rater Reliability of the Deep Tendon Reflex by using EMG Electric Reflex Hammer (근전도 전자 망치를 이용한 깊은힘줄반사의 측정자 간 신뢰도)

  • Lee, Jeong-Woo;Seo, Tae-Hwa
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.137-143
    • /
    • 2022
  • Purpose : The purpose of this study was to evaluate the reliability analysis of the deep tendon reflex by using electromyography (EMG). Methods : The study was tested on 30 volunteers who are women in their 20s. Using an electronic reflective hammer of EMG, deep tendon reflex was measured on all subjects with the participation of three trained physical therapists as raters. First, the subjects were comfortably seated on a table with their knees bent at 90 °. The three raters tapped the electric hammer at intervals of 10 seconds to avoid habituation until a total of 10 compound muscle action potential records were collected. Intraclass correlation coefficients (ICCs) were calculated to assess the inter-rater reliability of the deep tendon reflex with the use of EMG. The items of analysis included amplitude (mV), latency (ms), duration (ms), and area (mV × ms) of the compound evoked potentials. Results : Based on the average records of 10 compound muscle action potential, excellent reliability (ICC: .912) was achieved in terms of area, and there was good reliability in terms of latency (ICC: .795) and duration (ICC: .800). In the shortest latency of the compound muscle action potential, good reliability was achieved in terms of amplitude (ICC: .865), duration (ICC: .781), and area (ICC: .832). In the amplitude of peak-to-peak of compound muscle action potential, excellent reliability was recorded in terms of amplitude (ICC: .924), and good reliability was recorded in terms of duration (ICC: .801) and area (ICC: .874). Conclusion : The findings in this study indicate that electromyography via an electric hammer is a reliable method of assessing and measuring deep tendon reflexes. Especially, it may be an excellent gauge in the area of average values of the compound muscle action potentials and the amplitude of peak-to-peak of compound muscle action potentials.

Comparative Medium Term Results of Arthroscopic ACL Reconstruction with Quadrupled Semitendinosus Tendon versus BPB tendon (4겹의 반건양건과 골-슬개건-골을 이용한 관절경적 전방 십자 인대 재건술의 중기적 치료 결과 비교)

  • Kim, Hyoung-Soo;Park, Seung-Rim;Kang, Joon-Soon;Lee, Woo-Hyeong;Kim, Ki-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • Purpose : The purpose of this study was to compare the postoperative success and stability of arthroscopically assisted anterior cruciate ligament(ACL) reconstructions using central one third bone-patellar-tendon bone(BPB) autograft versus quadrupled semitendinos-us(ST) autograft as the medium term review. Materials and Methods : Eighty patients(40 BPBs,40 STs) with isolated ACL injury were available for a mean follow up of 49.4 months(BPB) and 48.8 months(ST). There was no significant difference between the two groups with respect to age and sex. We compare the final results between two groups with respect to subjective Lysholm score, objective laxity including anterior drawer test, Lachman test, pivot shift test, KT-2000 measurements and International Knee Documentation Committee(IKDC) evaluation system. Results : Postoperatively, positive anterior drawer test was found in $22.5\%\;and\;27.5\%$, positive Lachman test was found in $30.0\%$ and $25.0\%$ and positive pivot shift test was found in $15\%\;and\;20\%$ of the ST and BPB group, respectively(p>0.05). Mean side to side difference of KT-2000 at 20 lbs was 2.2 mm for the ST group and 2.1 mm for the BPB group. There was no significant difference between the two groups about Lysholm score(>0.05). Anterior knee pain was knee common in the BPB group. Eighty-three percent of the patients were nearly normal according to the IKDC grade in both groups. Conclusion : We consider that autogenous semitendinosus tendon is a good alternative subsititute in ACL reconstruction together with the bone-patellar tendon-bone autograft.

  • PDF

The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report - (생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 -)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Yang, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.87-90
    • /
    • 2006
  • The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.

  • PDF

Graft Length of the Bone-patellar Tendon-bone for Reconstruction of ACL (골-슬개건-골을 이용한 전방십자인대 재건술에서 이식물의 길이)

  • Kim, Jung-Man
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • Various surgical techniques has been advocated for reconstruction of anterior cruciate ligament using the bone-patella tendon-bone graft. Recently endoscopic technique provides good clinical results, with minimal skin incision, accurate positioning of the graft to the femoral tunnel, and decreasing wear rate of the graft. But the graft-tunnel mismatch remains problematic in endoscopic technique. The purpose of this paper is to described causes of the graft-tunnel mismatch and to provide important steps to prevent or minimize the graft-runnel mismatch following anterior cruciate ligament while using the endoscopic technique. Our guideline for prevention of the graft-tunnel mismatch are as follows: (1) The tunnel should he positioned closely to isometric point as much as possible. (2) Anterior placement of the tunnel should be avoided. (3) The change of graft length should be within 2mm between flexion and extension position.

  • PDF