• 제목/요약/키워드: Paste Electrode

검색결과 255건 처리시간 0.023초

Use of hybrid materials in the trace determination of As(V) from aqueous solutions: An electrochemical study

  • Tiwari, Diwakar;Jamsheera, A.;Zirlianngura, Zirlianngura;Lee, Seung Mok
    • Environmental Engineering Research
    • /
    • 제22권2호
    • /
    • pp.186-192
    • /
    • 2017
  • The carbon paste electrode (CPE) was modified with the pristine bentonite and hybrid material (HDTMA-modified bentonite). The modified-CPEs are then employed as working electrode in an electrochemical detection of As(V) from aqueous solutions using the cyclic voltammetric measurements. Cyclic voltammograms revealed that As(V) showed reversible behavior onto the working electrode. The hybrid material-modified carbon paste electrode showed significantly enhanced electrochemical signal which was then utilized in the low level detection of As(V). Moreover, the studies were conducted at neutral pH conditions. The electrochemical studies were conducted with scan rates (20 to 200 mV/s) to deduce the mechanism of redox processes involved at the electrode surface. The anodic current was linearly increased, increasing the concentration of As(V) from 5.0 to $35.0{\mu}g/g$ using the hybrid material-modified electrode. This provided fairly a good calibration line for As(V) detection. The presence of varied concentrations of As(III) in the determination of total arsenic was studied. The influence of several cations and anions viz., Cu(II), Mn(II), Zn(II), Pb(II), Cd(II), Fe(III), $Cl^-$, $NO_3{^-}$, $PO_4{^{3-}}$, EDTA and glycine in the detection of As(V) from aqueous solution was also studied. Further, in an attempt to simulate the real matrix analysis, the tap water sample was spiked with As(V) and subjected for As(V) detection using the modified-CPE.

절연체 종류에 따른 후막 전계 발광소자의 광학 및 전기적 특성 (Electrical and Optical Property of Powder Electroluminescent device at Dielectric variety)

  • 오주열;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1800-1802
    • /
    • 1999
  • Electroluminescence is occurred when phosphor is located in electric field. In this paper, we made powder electroluminescent device (PELD) with structured ITO film/phosphor/Insulator/silver paste. The transparent electrode was ITO film and green(2704-01) and orange(2702-02) and blue-green(2703-01) were used as phosphor. The insulator was $BaTiO_3$ and $Y_2O_3$, back electrode was silver paste. To investigate electrical and optical properties of PELDs, EL spectrum, Brightness, Transferred charge density using Sawyer-Towers circuit was measured.

  • PDF

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제34권3호
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

생체 세포내 미량 구리의 전기화학적 검출에 관한 연구 (Electrochemical Detection of Trace Level Copper in in vivo Cell)

  • 이장현
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1333-1338
    • /
    • 2012
  • In order to measure the minute amount of Cu(II) in our environment, cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV) were performed for a trace copper assay using bismuth immobilized on a carbon nanotube paste electrode. An analytical working range of 30 to $240{\mu}g/L$ Cu(II) was obtained for CV and SWSV. The SWSV precision obtained was 0.47 % (n = 15) RSD in $30.0{\mu}g/L$ Cu(II). The detection limit obtained was 3.1 ng/L Cu(II) using SWSV, while the CV yielded the nano-range detection limit through the pre-concentration step. By using this research method, Cu(II) value could be determined in the urine of human sample and in the brain of fish sample. This research can be effectively applied to other cases of measuring minute amount of Cu(II) in living organisms.

Photosensitive Electrode Paste Formulation and Its Effect on Photolithographic Process

  • Park, Lee-Soon;Im, Moo-Sik;Park, Jin-Woo;Kim, Hong-Tak;Ryu, Jae-Hwa;Park, Seung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.381-384
    • /
    • 2003
  • Photosensitive electordes(Ag and Black) are widely used in the patterning of both address and bus electrodes on the rear and front panel of plasma display panel (PDP). As the need for high resolution(>XGA) and large area(>60 inches) PDP is increased, basic understanding of each component of formulation on the photolithographic process of patterning electrodes are required in order to increase the yield in the production of PDP. In this work, the materials and amount of necessary components of photosensitive electrode paste and their effect on the photolithographic process of patterning electrodes were studied.

  • PDF

Electrochemical Determination of Ciprofloxacin Based on the Enhancement Effect of Sodium Dodecyl Benzene Sulfonate

  • Zhang, Shenghui;Wei, Shuang
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.543-546
    • /
    • 2007
  • Herein, a new electrochemical method was described for the determination of ciprofloxacin based on the enhancement effect of an anionic surfactant: sodium dodecyl benzene sulfonate (SDBS). In pH 4.0 phosphate buffer and in the presence of 1.0 × 10-4 mol/L SDBS, ciprofloxacin yields a well-defined and sensitive oxidation peak at the carbon paste electrode (CPE). Compared with that in the absence of SDBS, the oxidation peak current of ciprofloxacin remarkably increases in the presence of SDBS. The experimental parameters, such as supporting electrolyte, concentration of SDBS, and accumulation time, were optimized for ciprofloxacin determination. The oxidation peak current is proportional to the concentration of ciprofloxacin over the range from 8.0 × 10-8 to 5.0 × 10-6 mol L-1. The detection limit is 2.0 × 10-8 mol L-1 after 2 min of accumulation. This new voltammetric method was successfully used to detect ciprofloxacin in drugs.

후막 EL 소자의 광학 및 이동전하밀도 특성 (Transferred charge density and Optical Property on Powder Electroluminescent device)

  • 오주열;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.286-290
    • /
    • 1999
  • Electroluminescence is occurred when phosphor is located in electric field. In this paper, we made powder electroluminescent device (PELD) with structured ITO film/Phosphor/Insulator/Silver paste. The transparent electrode was ITO film and green(2704-01), orange(2702-02) and blue-green(2703-01) were used as phosphor. The insulator was BaTiO$_3$ and $Y_2$O$_3$, back electrode was silver paste. To investigate electrical and optical properties of PELDs, EL spectrum, Brightness, Transferred charge density using Sawyer-Tower\`s circuit was measured.

  • PDF

산화루테늄계 후막 저항기의 과도한 전류잡음에 관한 고찰 (Study on the Excessive Current Noise in $RuO_2$ Thick Film Resistors)

  • 김지호;김진용;임한조;신철재;박홍이
    • 전자공학회논문지A
    • /
    • 제29A권3호
    • /
    • pp.79-86
    • /
    • 1992
  • The cause of excess current noise which appears some times in RuO$_2$ thick film chip resistors and the process to reduce such noise are investigated. We observed that too large thermal expansion coefficients of resistor paste and electrode metal paste can induce the mechanical stress and microcracks in the contact region of the two sintered materials. Such microcracks result in the reduction of conduction paths in the sintered electrode and this provokes the increase of the resistance value and the current noise. Such excessive current noise induced by microcracks could be reduced or even eliminated by using an enlarged overcoat patterns in the plating process or by adding an additional annealing process before plating.

  • PDF

유전체 종류에 따른 후막 전계발광(EL) 소자의 특성 (Properties of Powder Electroluminescent Device with $Y_2O_3 and BaTiO_3$)

  • 이종찬;박춘배;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.582-585
    • /
    • 1999
  • Electroluminescence is occurred when phosphor is located in electric field. In this paper, we made powder electroluminescent device (PELD) with structured ITO film/Phosphor/Insulator/Silver paste. The transparent electrode was ITO film and green(2704-01) and orange(2702-02) and blue-preen(2703-01) were used as phosphor. The insulator was BaTiO$_3$ and $Y_2$O$_3$, bark electrode was silver paste. To investigate electrical and optical properties of PELDs, EL spectrum, Brightness . Transferred charge density using Sawyer-Towers circuit was measured.

  • PDF

후막형 용존 산소 센서의 전기적 특성 (Electrical properties of thick film dissolved oxygen sensors)

  • 이경준;정경진;이성필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.92-95
    • /
    • 2003
  • The dissolved oxygen sensors with thick film type were fabricated for low cost products and the electrical properties were investigated in the different operating temperatures. Pt paste was used for working electrode and Ag/AgCl paste for reference electrode. The fabricated devices have fast response of current changes according to dissolved oxygen concentrations in the applied voltage of $0.6{\sim}0.8V$. This is expected to apply a chip and/or disposal dissolved oxygen sensors.

  • PDF