• 제목/요약/키워드: Paste Electrode

검색결과 255건 처리시간 0.025초

Flexible OTFT-OLED Display Panel using Ag-paste for Source and Drain Electrodes

  • Ryu, Gi-Seong;Kim, Young-Bea;Song, Hyun-Jin;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1789-1791
    • /
    • 2007
  • We fabricated OTFT-OLED display panel by using Ag-paste for source and drains electrode of OTFTs. The OTFTs were fabricated by solution processes such as spin-coating for PVP gate dielectric and screen printing for S/D electrodes with Ag-paste, except pentacene active layer which was deposited by evaporation. The mobility was 0.024 cm2/V.sec , off state current ${\sim}10-11A$, threshold voltage 7.6 V and on/off current ratio ${\sim}105$. The panel consisted of 16 x 16 pixels and each pixel consisted of 2 OTFTs, 1 Capacitor and 1 OLED. The pixels successfully worked in terms of current magnitude supplied to OLED and the control ability of driving and switching OTFTs.

  • PDF

Simultaneous Detection of Tartrazine-Sunset Yellow in Food Samples Using Bioxide/Carbon Paste Microcomposite with Lanthanum and Titanium

  • Nagles, Edgar;Ceroni, Mario;Hurtado, John
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권4호
    • /
    • pp.421-429
    • /
    • 2020
  • This report describes the simultaneous detection of the two dyes most commonly used in food, tartrazine (TZ) and sunset yellow (SY), based on a microcomposite of carbon paste decorated with La2O3 and TiO2. Anodic currents for SY-TZ were observed at 0.89-1.21 V by cyclic voltammetry (CV) separated with a ΔV of 0.32 V. The increased anodic peak currents compared to that of the unmodified carbon paste electrode were almost 50 and 41% for SY-TZ, respectively. The detection limits with the optimal amount of La2O3-TiO2 were 0.02 and 0.03 µmol/L, respectively. The relative standard deviation (RSD) based on fifty measurements was less than 3%. The versatility and novelty of the sensor were tested with food samples containing these substances and other substances.

Normalized Contact Force to Minimize "Electrode-Lead" Resistance in a Nanodevice

  • Lee, Seung-Hoon;Bae, Jun;Lee, Seung Woo;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2415-2418
    • /
    • 2014
  • In this report, the contact resistance between "electrode" and "lead" is investigated for reasonable measurements of samples' resistance in a polypyrrole (PPy) nanowire device. The sample's resistance, including "electrode-lead" contact resistance, shows a decrease as force applied to the interface increases. Moreover, the sample's resistance becomes reasonably similar to, or lower than, values calculated by resistivity of PPy reported in previous studies. The decrease of electrode-lead contact resistance by increasing the applying force was analyzed by using Holm theory: the general equation of relation between contact resistance ($R_H$) of two-metal thin films and contact force ($R_H{\propto}1/\sqrt{F}$). The present investigation can guide a reliable way to minimize electrode-lead contact resistance for reasonable characterization of nanomaterials in a microelectrode device; 80% of the maximum applying force to the junction without deformation of the apparatus shows reasonable values without experimental error.

폴리부타디엔 결합재를 이용하여 만든 탄소반죽전극의 전기화학적 특성에 관한 연구 (Investigations with respect to the electrochemical properties of carbon paste electrode fabricated using polybutadiene binder)

  • 윤길중
    • 분석과학
    • /
    • 제20권1호
    • /
    • pp.49-54
    • /
    • 2007
  • For the practical use as a biosensor, a rubber electrode bound by polybutadiene was newly devised for the determination of hydrogen peroxide. Then its electrochemical behaviors were investigated. The signal could be obtained at low electrode potential between 0.0 ~ -0.5 V (vs. Ag/AgCl) with a detection limit of $1.4{\times}10^{-4}M$ and its potential dependence was linear in the experimental range. Especially its Lineweaver-Burk plot showed a very good linearity giving the evidence of a good enzyme immobilization on the surface of the electrode. And mechanical stability of the electrode resulted from using rubber binder presented a new possibility for the practical use of biosensor.

Ceramic PTC thermistor의 금속접촉저항과 입계전위장벽 (Analysis on Metal Contact Resistance and Grain Boundary Barrier Height of Ceramic PTC Thermistor)

  • 전용우;임병재;홍상진;소대화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.235-236
    • /
    • 2006
  • The contact resistance and grain boundary potential barrier of ceramic $BaTiO_3$ PTCR were investigated. The electroless plated Ni, evaporated Al, and Ag paste were chosen as electrode materials of PTCR device for comparison analysis before and after heat treatment. The contact resistance of electrode were measured by electrometer (dc), digital multimeter (dc), and LCR meter (ac). In the case of Al electroded samples, the heat treatment and protective oxide layer had high resistance and effect on the stability of PTCR effect against contact resistance degradation, but the Ag-paste had comparably high contact resistance before heat treatment and decreased after heat treatment with safe. On the other hand, the samples with electroless plated Ni electrode had good properties of contact resistance against aging.

  • PDF

열형-롤 각인으로 형성한 Ag 격자 패턴과 전도성 고분자 코팅을 이용한 투명전극 필름 제작에 관한 연구 (Study and Fabrication of Transparent Electrode Film by using Thermal-Roll Imprinted Ag Mesh Pattern and Coated Conductive Polymer)

  • 유종수;조정대;윤성만;김도진
    • 한국정밀공학회지
    • /
    • 제27권9호
    • /
    • pp.11-15
    • /
    • 2010
  • In this study, to fabricate a low-resistance and high optical transparency electrode film, the following steps were performed: the design and manufacture of electroforming stamp, the fabrication of a thermal roll-imprinted polycarbonate (PC) patterned films, the filled low-resistance Ag paste using doctor blade process on patterned PC films and spin coating by conductive polymers. As a result of PC films imprinted line width of $26.69{\pm}2\;{\mu}m$, channel length of $247.57{\pm}2\;{\mu}m$, and pattern depth of $7.54{\pm}0.2\;{\mu}m$. Ag paste to fill part of the patterned film with conductive polymer coating and then the following parameters were obtained: a sheet resistance of $11.1\;{\Omega}/sq$ optical transparency values at a wavelength of 550 nm was 80.31 %.

밀폐식 Ni-Cd 전지의 충전특성에 관한 연구 (Study on the Charging Characteristics of a Sealed Type Ni-Cd Cell)

  • 박영우;김재원;전무식
    • 대한화학회지
    • /
    • 제15권6호
    • /
    • pp.347-352
    • /
    • 1971
  • The variations of the positive and negative electrode potentials, and of internal pressure were measured during the charge of the sealed type Ni-Cd cell. Both polarization characteristics of a paste type Cd-electrode as a gas diffusion electrode in 30% KOH solution and the effects of active carbon electrode as an oxygen consuming auxiliary electrode of the Ni-Cd cell on the charging characteristics of the cell were studied. Peak voltage at the end of charge of the cell is ascribed to the peak at the negative electrode potential, which is due to the concentration polarization by the lack of $Cd^{++}$ ion and oxygen concentration. And the recovery of the negative electrode potential is resulted from depolarization by the increasing diffusion limiting current density with the increasing oxygen pressure. The active carbon electrode was effective as an oxygen consuming auxiliary electrode. The internal pressure of the cell could be maintained below 200mmHg even at one hour rate charge and overcharge by the use of active carbon electrode as an auxiliary electrode.

  • PDF

네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출 (Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry)

  • 부한길;송연주;박세진;정택동
    • 전기화학회지
    • /
    • 제13권1호
    • /
    • pp.63-69
    • /
    • 2010
  • 플루오로퀴놀론 계 항생제들의 전기화학적 거동을 카본 페이스트 전극 (carbon paste electrode ; CPE)을 사용하여 순환 전압전류법 (cyclic voltammetry)과 네모파 흡착 벗김 전압전류법 (square wave adsorptive stripping voltammetry)으로 연구하였다. Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL), Levofloxacin (LEV) 등 5가지 플루오로퀴놀론 계 항생제에 대한 전기화학적 분석을 수행하였다. pH 4.5인 아세트산 완충 용액 (acetate buffer) 에서 플루오로퀴놀론 계 항생제의 산화 전위는 Ag/AgCl 기준 전극에 대하여 각각 ENR : 0.952V, NOR : 1.052 V, CIP : 1.055 V, OFL : 0.983 V, LEV : 0.990 V 의 값을 나타내었으며, 네모파 흡착 벗김 전압전류법에 의한 산화 전류는 $0.2\;{\mu}M$에서 $1\;{\mu}M$ 사이의 농도영역에서 각 항생제의 농도와 선형을 나타내었다.

활성탄소 전극의 제조공정에 따른 EDLC의 전기화학적 특성 (Electrochemical Characteristics of EDLC Fabricated by Different Preparation Processes of Activated Carbon Electrode)

  • 양천모;김현중;조원일;조병원;윤경석;임병오
    • 전기화학회지
    • /
    • 제4권3호
    • /
    • pp.98-103
    • /
    • 2001
  • EDLC(electric double layer capacitor)용 활성탄소전극의 제조공정을 dip coating method, doctor blade coating method, paste rolling method로 달리하여 전기화학적 특성과 비축전 용량을 조사하였다. Dip coating method에 의한 전극제조시 전해질염으로 LiPF6를 이용하고 유기용매로 PC-DEC를 이용한 EDLC의 비축전 용량이 130F/g으로 가장 우수하였고, 선형의 시간전압곡선에서의 IR-drop도 0.11V로 작았으며 CV(cyclic voltammetry) 분석 또한 이상적인 EDLC의 특성을 나타내었다.

Bonding Strength of Conductive Inner-Electrode Layers in Piezoelectric Multilayer Ceramics

  • Wang, Yiping;Yang, Ying;Zheng, Bingjin;Chen, Jing;Yao, Jinyi;Sheng, Yun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권4호
    • /
    • pp.181-184
    • /
    • 2017
  • Multilayer ceramics in which piezoelectric layers of $0.90Pb(Zr_{0.48}Ti_{0.52})O_3-0.05Pb(Mn_{1/3}Sb_{2/3})O_3-0.05Pb(Zn_{1/3}Nb_{2/3})O_3$ (0.90PZT-0.05PMS-0.05PZN) stack alternately with silver electrode layers were prepared by an advanced low-temperature co-fired ceramic (LTCC) method. The electrical properties and bonding strength of the multilayers were associated with the interface morphologies between the piezoelectric and silver-electrode layers. Usually, the inner silver electrodes are fabricated by sintering silver paste in multi-layer stacks. To improve the interface bonding strength, piezoelectric powders of 0.90PZT-0.05PMS-0.05PZN with an average particle size of $23{\mu}m$ were added to silver paste to form a gradient interface. SEM observation indicated clear interfaces in multilayer ceramics without powder addition. With the increase of piezoelectric powder addition in the silver paste, gradient interfaces were successfully obtained. The multilayer ceramics with gradient interfaces present greater bonding strength as well as excellent piezoelectric properties for 30~40 wt% of added powder. On the other hand, over addition greatly increased the resistance of the inner silver electrodes, leading to a piezoelectric behavior like that of bulk ceramics in multilayers.