• Title/Summary/Keyword: Passive soil resistance

Search Result 24, Processing Time 0.026 seconds

Finite Element Analysis of the Direct Shear Test (직접 전단시험의 유한 요소 해석)

  • 이장덕
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.21-36
    • /
    • 1996
  • The stress transfer mechanism between soil and grid reinforcements involves two basic mechanism : frictional soil resistance and passive soil resistance. However the mechanism of the passive soil resistance is very complex to understand. To study the failure mechanism of ribbed reinforcement, the direct shear tests which are dominated by passive soil resistance are analyzed by using the finite element method. The finite element method is used to examine the effects of ribs on this passive soil resistance development and the met hanism of failure. The calculated behavior of the ribbed reinforcement is compared with the measured behavi or. Comparisons between the measured and the simulated strain pat terns, failure modes and load displacement relationship are presented. The behavior of the ribbed reinforcements in a cohesive soil is predicted on the basis of a good agreement between the measured and the Predicted behavior of the Ottawa sand.

  • PDF

Pullout resistance of concrete anchor block embedded in cohesionless soil

  • Khan, Abdul J.;Mostofa, Golam;Jadid, Rowshon
    • Geomechanics and Engineering
    • /
    • v.12 no.4
    • /
    • pp.675-688
    • /
    • 2017
  • The anchor block is a specially designed concrete member intended to withstand pullout or thrust forces from backfill material of an internally stabilized anchored earth retaining wall by passive resistance of soil in front of the block. This study presents small-scale laboratory experimental works to investigate the pullout capacity of a concrete anchor block embedded in air dry sand and located at different distances from yielding boundary wall. The experimental setup consists of a large tank made of fiberglass sheets and steel framing system. A series of tests was carried out in the tank to investigate the load-displacement behavior of anchor block. Experimental results are then compared with the theoretical approaches suggested by different researchers and codes. The appropriate placement of an anchor block and the passive resistance coefficient, which is multiplied by the passive resistance in front of the anchor block to obtain the pullout capacity of the anchor, were also studied.

Pullout Resistance of Geosynthetic Strip with Rounded Band Anchor (수동저항부가 형성된 띠형 섬유보강재의 인발저항 특성)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.3
    • /
    • pp.43-51
    • /
    • 2011
  • This paper describes the results of pullout tests in the laboratory, which are conducted to assess the pullout performance of recently developed geosynthetic strip reinforcement with rounded band anchor. The geosynthetic strip can be used as reinforcements in reinforced soil wall with concrete block facing. The pullout resistance of the geosynthetic strip with rounded band anchor is mobilized by the combination of the interface friction between soil-reinforcement surface and the passive soil resistance caused by the rounded band anchor. Therefore, both the friction resistance and the passive resistance have to be considered in design. From the pullout test results, when the rounded band anchor are formed in the end part of the geosynthetic strip, pullout strength increases about from 10% to 65%. The passive resistance can be evaluated based on the pullout test results.

An Evaluation of Pullout Behavior Characteristics of the Steel Strip Reinforcement Bolted with Braced Angles (버팀재 볼트 접합형 강재스트립 보강재의 인발거동특성 평가)

  • 김홍택;방윤경;정중섭;박시삼;김현조
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.419-426
    • /
    • 2002
  • In this study, the steel strip reinforcement bolted with braced angles is displayed skin friction resistance as well as passive resistance through existing the steel strip reinforcement. To understand pullout behavior characteristics, friction effects between soil and reinforcement are evaluated with the width of reinforcement, magnitude of surcharge, and existence of passive resistance member through laboratory pullout test. To analyze interference effects for passive resistance member, various tests are carried on case that the number, the location, and the spacing of braced angles are different. Using this test result, pullout resistance factor is calculated to consider location of braced angles and degree of interference for spacing ratio.

  • PDF

Evaluation of Weathered Granite Soil l Geogrid Friction Properties and Pull out Test (화강 풍화토/지오그리드 인발시험 및 마찰특성 평가)

  • 조삼덕;김진만
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.87-100
    • /
    • 1996
  • The pull -out test has been used to investigate the friction properties between soil and grid type geosynthetics which is useful to measure the passive bearing resistance as well as the skin friction. In this paper, the friction properties between geogrid and a weathered granite soil are investigated by performing various pull-out tests. From the test results, a rational pull out test equipment and test method is suggested by evaluating the effects of major factors (such as geogrid width, location of soil box facing, vertical loads and pulll -out displacement rate, etc.) on pull -out test results.

  • PDF

A Study of Rectangular-shaped Passive Row Piles in Horizontal Sand-ground under Lateral Soil Movement by Model Test (수평모래지반에서 측방변형을 받는 사각형 수동 열말뚝에 관한 실험적 연구)

  • Bae, Jong-Soon;Kwon, Min-Jea
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.23-36
    • /
    • 2008
  • This study describes model tests on instrumented rectangular-shaped passive row piles embedded in horizontal sand-ground undergoing lateral soil movement. We tried to find the property of row piles dependent on the shape of pile, including the position of the pile in row, pile spacing, and soil movement. The results of test are as follows. The lateral earth pressure diagram variously appeared to be triangle, trapezoid and rectangular by shape and position of pile. The outer pile has a larger bending moment than the inner pile in the case of B-type, the inner piles has larger one than outer pile in case of H-type. $R_f$ (the ratio of resistance to lateral soil movement) was found to increase with increasing pile spacing irrespective of pile-shape. Y/L (location of action of lateral resistance force) for $d_s$ (displacement of soil) and $S_h$ (spacing of pile) appeared to be nearly regular position, and H-type is higher than B-type.

Study of Soil Nailing Application as a Reinforcement Method for Slided Slope (붕괴사면보강을 위한 Soil Nailing의 적용성에 관한 연구)

  • 이성철;김명학
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.127-134
    • /
    • 2000
  • Soil nailing is in-situ ground improvement technique of reinforcing soils using passive inclusions for the purpose of slope stability. Also soil nailing, in general, was used and studied as a reinforcement technique at cut slope, but this paper presents the results of study for soil nailing application as a reinforcement technique at the banking over slided slope. In-situ pull-out tests of nails, instrumented with strain gauges, were performed to investigate the maximum pull-out load and to calculate the unit side resistance in each different layer. And the apparent average unit side resistance of this study was compared with that of other sites installed at cut slope.

  • PDF

A Study on the Rectangular-Shaped Passive Row Piles in Inclined Sand-Ground by Model Test (경사모래지반의 사각형 수동 열말뚝에 관한 실험적 연구)

  • Bae, Jong-Soon;Kim, Ji-Seong;Kwon, Min-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.39-51
    • /
    • 2009
  • This is a study on rectangular-shaped passive row piles in inclined sand-ground by model tests. The experiment controlled the angle of inclination of ground and induced the ground destruction. We also measured the behavior of row piles, by adjusting the shape, position and spacing of piles. As a result, we confirmed the earth pressure, the lateral resistance, and the effect of depressing on the ground variation working on passive pile. The effect of B-type pile of which the front width is wide is bigger than that of H-type pile of which the side width is wide. We can find out the failure angle of slope, the shared force of pile and soil by using the lateral resistance graph based on slope angle.

The effect of base isolation and tuned mass dampers on the seismic response of RC high-rise buildings considering soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.425-434
    • /
    • 2019
  • The most effective passive vibration control and seismic resistance options in a reinforced concrete (RC) high-rise building (HRB) are the base isolation and the tuned mass damper (TMD) system. Many options, which may be suitable or not for different soil types, with different types of bearing systems, like rubber isolator, friction pendulum isolator and tension/compression isolator, are investigated to resist the base straining actions under five different earthquakes. TMD resists the seismic response, as a control system, by reducing top displacement or the total movement of the structure. Base isolation and TMDs work under seismic load in a different way, so the combination between base isolation and TMDs will reduce the harmful effect of the earthquakes in an effective and systematic way. In this paper, a comprehensive study of the combination of TMDs with three different base-isolator types for three different soil types and under five different earthquakes is conducted. The seismic response results under five different earthquakes of the studied nine RC HRB models (depicted by the top displacement, base shear force and base bending moment) are compared to show the most suitable hybrid passive vibration control system for three different soil types.