• Title/Summary/Keyword: Passive heating

Search Result 135, Processing Time 0.02 seconds

A study on the Optimum Design Configuration of Passive Solar TI-wall system (투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구)

  • Kim, Byoung-Soo;Yoon, Jong-Ho;Yoon, Yong-Jin;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

Mobile Energy Shelter House(MeSH) for victims when a disaster occurs - Focused on Indoor Thermal Environmental Performance - (재난·재해 시 이재민을 위한 이동형 에너지 셜터하우스 (MeSH) 계획 -실내 온열환경 성능을 중심으로-)

  • Shin, Hwayeon;Kim, Jeonggook;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheolyong;Hong, Wonhwa
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.75-80
    • /
    • 2014
  • Development of temporary housing for victims whose house damaged is required. In this study is to plan temporary house space 'Mobile Energy Shelter House ; MeSH' that can be inhabited for a long time. And measure the indoor Environmental performance. 'Mobile Energy Shelter House : MeSH' was made by reflecting Passive Design, Universal Design. Also, thermal insulation that meets the 'Korea standard insulation' for use low energy. Winter season, measuring temperature, humidity, air velocity and radiation temperature when floor heating that temperature controllers ware installed is used. Confirmed the data for the 8:00pm to 8:00am because evening hours are expected as residents live. Average outdoor temperature was $-11.3^{\circ}C$ and Indoor temperature was from $16.09^{\circ}C$ to $20.63^{\circ}C$. Calculated the TDRi of the window surface for checked condensation risk. TDRi value was 0.185. Furthermore, PMV value was -0.08 to -0.85. It was satisfied to ISO comfort criterion ranged.

Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 나노세라믹 필터의 성능 평가)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

A Study on the Allergenicity of Egg Protein (달걀 단백질의 Allergenicity에 관한 연구)

  • 정은자
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.228-236
    • /
    • 1998
  • Egg is an important foods containing many good proteins. But it is well known that egg protein has a lot of allergenicity. The purpose of this study is to develop the methods to reduce the allergenicity of egg. I tried various experimental methods ; For example, heat treatment, irradiation with ultraviolet and microwaves, treatment with polyphosphate, enzyme hydrolysis and PCA inhibition test using guinea pigs and degrees of hydrolysis. The results obtained were as follows ; 1. Heat treatment reduced allergenicity of egg protein. The longer the heat time, the better the effect. 2. Irradiating with ultraviolet and microwave increased both the degree of protein hydrolysis and PCA inhibition reduced the allergenicity. Ultraviolet was more effective than microwaves on egg protein. Fertilized eggs did not reduce allergenicity. 3. Enzyme treatment increased the degree of hydrolysis and PCA inhibition, and reduced allergenicity considerably. Alcalase was more effective than neutrase. 4. Adding polyphosphate did not induced protein hydrolysis, but increased PCA inhibition and reduced allergenicity. 5. The picture of various treatments of egg gel by SEM showed a light surface which indicated that protein was desolved. Neutrase was lighter than alcalase, and the longer the heating time, the lighter the surface became. 6. Measurements of the hardness of egg gel by Instron showed that the longer the reaction time with enzyme, the softer it became.

  • PDF

Development of Nano Ceramic Structures for HEPA Type Breathing Wall (HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발)

  • Kim, Jong-Won;Ahn, Young-Chull;Kim, Gil-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

To reduce carbon from residential architecture Research on energy-saving elements (주거건축에서 탄소를 줄이기 위한 에너지 절감 요소에 관한 연구)

  • Park, Jae-Hee
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.47-52
    • /
    • 2009
  • Currently, the environmental issue is of great urgency and sensitivity to the future of our planet. Global warming caused by increased CO2 concentration has an alarming impact on the earth's fragile environment. Droughts throughout the world are causing crop failures. Wildfires now burn with far greater rage. Melting ice caps and glaciers are causing floods. Sea levels are rising. Warm unseasonable winters are threatening our fragile eco-systems. Global warming is no longer a theory; it is an obvious fact we are confronted with every day, and the only way we can prevent it is to take action now. The need to reduce CO2 emissions and try to become carbon neutral is of national importance and leadership. We have become so reliant on fossil fuels that nearly everything we do generates CO2 emissions; from our modern farming practices to transport, to the electricity used to turn on a light, boil water in a kettle or cook our meals. A reduction of 50% of CO2 emissions can easily be achieved by decreasing the energy amount used. We tracked the carbon footprint throughout the electricity and heating energy use in homes and confirmed the amount of carbon emissions according to its consumptions. In order to reduce the carbon generation from housing constructions, such as Passive House concept of buildings or low energy buildings, we must adjust its applications best fit to our conditions. And technical elements should be applied to improve our conditions, and the methodology should be actively sought. Most of all, each individual's recongnition who uses these elements is more important than any other solutions.

Design and Energy Performance Evaluation of Plus Energy House (플러스에너지하우스 설계 및 에너지 성능 평가)

  • Kim, Min-Hwi;Lim, Hee-Won;Shin, U-Cheul;Kim, Hyo-Jung;Kim, Hyun-Ki;Kim, Jong-Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.2
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building (차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구)

  • Park, Se-Hyeon;Kang, Jun-Gu;Bang, Ah-Young;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building (제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구)

  • Sung, Uk-Joo;Rim, Min-Yeop;Kim, Seok-Hyun;Cho, Soo
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface (온도 변색 도료의 지붕 적용 및 냉방효과 분석)

  • Baek, Sanghoon
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.115-123
    • /
    • 2022
  • This study aims to introduce a temperature discoloration roof system and its cooling effect in the summer. Temperature discoloration paints can reverse their colors based on temperature changes. If these paints on the roof surface could color-shift between white in the summer and black in the winter, the indoor cooling and heating loads can be affected by the changes in reflection and absorption of solar radiation. Focusing on the summer period, the study analyzed the cooling effect of applying temperature discoloration paint that color-shifts from white to black on the roof surface of a small experimental building module and compared it to commonly used gray and green roof colors. Results of the experiment showed that the surface temperature of the roof with temperature discoloration paint was lower than the gray and green color roofs by a maximum of 10℃. Furthermore, the indoor temperature of the experimental module with the temperature discoloration roof was lower than the gray and green roofs by approximately 3℃. Findings of the study indicate that the application of temperature discoloration paint to the roof can reduce indoor cooling loads.