• 제목/요약/키워드: Passive heating

검색결과 133건 처리시간 0.026초

초미세입자 제거를 위한 나노세라믹 필터의 성능 평가 (Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

달걀 단백질의 Allergenicity에 관한 연구 (A Study on the Allergenicity of Egg Protein)

  • 정은자
    • 한국식품영양학회지
    • /
    • 제11권2호
    • /
    • pp.228-236
    • /
    • 1998
  • 달걀의 Allergenicity를 감소시킬 수 있는 방안을 강구하고자 물리적 처리, 축합 인산염 처리 및 효소처리를 하여 Guinea pig를 이용한 Passive Cutaneous Anaphylaxis(PCA) inhibition 실험과 Non Proteic Nitrogen(NPN)정량을 통한 가수분해율의 측정결과 다음과 같은 결론을 얻었다. 달걀의 allergenicity는 가열에 의해 감소하였으며 가열시간이 길수록 단백질 가수분해율 및 PCA inhibition을 증가 시켰다. Ultraviolet 조사와 Microwave 조사는 단백 가수분해율과 PCA inhibition을 증가 시켜서 allergenicity를 저하시켰으며 ultraviolet이 저해효과가 더 컸으며 부화 달걀은 allergenicity를 감소시키지 않은 것으로 나타났다. 효소처리는 단백질의 가수분해율 및 PCA inhibition을 증가 시키며 allergenicity를 현저히 감소시켰으며 alcalase의 재해효과가 더 컸다. Polyphosphate의 참가는 단백질의 가수분해는 유도하지 않았으나 PCA inhibition을 증가 시키며 allergenicity를 감소시켰다. Allergenicity를 감소시키기 위한 처리를 한 달걀 gel의 주사전자현미경 사진은 효소처리 시 표면이 밝게 나타나서 단백질이 분해되었음을 알 수 있었고 neutrase가 alcalase보다 밝게 나타났으나 반응시간의 증가에 따라 모든 효소 표면이 밝게 나타났다. Instron에서 달걀 gel의 경도를 측정한 결과 효소와의 반응시간이 길수록 경도가 감소하는 경향을 보였다.

  • PDF

HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발 (Development of Nano Ceramic Structures for HEPA Type Breathing Wall)

  • 김종원;안영철;김길태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

주거건축에서 탄소를 줄이기 위한 에너지 절감 요소에 관한 연구 (To reduce carbon from residential architecture Research on energy-saving elements)

  • 박재희
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.47-52
    • /
    • 2009
  • Currently, the environmental issue is of great urgency and sensitivity to the future of our planet. Global warming caused by increased CO2 concentration has an alarming impact on the earth's fragile environment. Droughts throughout the world are causing crop failures. Wildfires now burn with far greater rage. Melting ice caps and glaciers are causing floods. Sea levels are rising. Warm unseasonable winters are threatening our fragile eco-systems. Global warming is no longer a theory; it is an obvious fact we are confronted with every day, and the only way we can prevent it is to take action now. The need to reduce CO2 emissions and try to become carbon neutral is of national importance and leadership. We have become so reliant on fossil fuels that nearly everything we do generates CO2 emissions; from our modern farming practices to transport, to the electricity used to turn on a light, boil water in a kettle or cook our meals. A reduction of 50% of CO2 emissions can easily be achieved by decreasing the energy amount used. We tracked the carbon footprint throughout the electricity and heating energy use in homes and confirmed the amount of carbon emissions according to its consumptions. In order to reduce the carbon generation from housing constructions, such as Passive House concept of buildings or low energy buildings, we must adjust its applications best fit to our conditions. And technical elements should be applied to improve our conditions, and the methodology should be actively sought. Most of all, each individual's recongnition who uses these elements is more important than any other solutions.

플러스에너지하우스 설계 및 에너지 성능 평가 (Design and Energy Performance Evaluation of Plus Energy House)

  • 김민휘;임희원;신우철;김효중;김현기;김종규
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.55-66
    • /
    • 2018
  • South Korea aims to shift the 20 percent of electricity supplement from the fossil fuel including the nuclear to renewable energy systems by 2030. In order to realize this agenda in the buildings, the plus energy house is necessary to increase the renewable energy supplement beyond the zero energy house. This paper suggested KePSH (KIER Energy-Plus Solar House) and energy performance of house and renewable energy systems was investigated. The KePSH has the target of generating 40% surplus energy than the conventional house energy consumption. The plus energy house is the house that generates surplus energy from the renewable energy sources than that consumes. In order to minimize the cooling and heating load of the house, the shape design and passive parameters design were conducted. Based on the experimental data of the plug load in the typical house, the total energy consumption of the house was estimated. This paper also suggested renewable energy sources integrated HVAC system using air-source heat pump system. Two cases of renewable energy system integration methods were suggested, and energy performance of the cases was investigated using TRNSYS 17 program. The results showed that the BIPV (building integrated photovoltaic) system (i.e., CASE 1) and BIPV and BIST system (i.e., CASE 2) shows 42% and 29% of plus energy rate, respectivey. Also, CASE 1 can generate 59% more surplus energy compared with the CASE 2 under the same installation area.

차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구 (A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building)

  • 박세현;강준구;방아영;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구 (A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building)

  • 성욱주;임민엽;김석현;조수
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

온도 변색 도료의 지붕 적용 및 냉방효과 분석 (Analysis on the Cooling Effect of Applying Temperature Discoloration Paint to a Roof Surface)

  • 백상훈
    • 토지주택연구
    • /
    • 제13권4호
    • /
    • pp.115-123
    • /
    • 2022
  • 본 연구는 지붕 표면에 온도 변색 도료(Thermochromic paint) 적용에 따른 지붕 표면 온도 저감 및 실내 냉방 효과를 분석하는 것에 목적이 있다. 본 도료는 특정 온도에서 색상이 변화되는 특징을 갖는다. 만약 본 도료를 적용함으로서 지붕 표면이 여름철에는 흰색으로, 겨울철에는 검정색으로 계절에 따라 변화될 수 있다면, 여름철에는 일사를 반사하여 실내 냉방 효과를 발휘할 수 있고, 겨울철에는 일사를 흡수하여 난방 효과를 가져올 수 있다. 이 중, 본 논문에서는 본 도료에 의해 여름철에 지붕의 표면 온도와 실내 온도가 어느 정도 감소되는지에 대해 실증 실험 및 기존 도료와의 비교를 통해 그 성능을 확인하였다. 그 결과, 온도 변색 도료가 적용된 지붕의 표면온도는 기존 도료의 경우보다 대략 5~10℃ 정도 낮게 나타났으며, 이로 인해, 실내 기온 또한 기존보다 대략 3℃ 이상 낮게 분석되었다. 따라서 온도 변색 도료는 여름철 높은 표면 온도를 유지하는 지붕에 적용 될 시, 표면 온도를 크게 감소시켜 실내 냉방효과를 발휘할 수 있는 것으로 확인되었다.

Pt/TiO2 코팅 세라믹 허니컴 촉매를 이용한 수소 제어 (Hydrogen Recombination over Pt/TiO2 Coated Ceramic Honeycomb Catalyst)

  • 강연석;김성수;서필원;이승현;홍성창
    • 공업화학
    • /
    • 제22권6호
    • /
    • pp.648-652
    • /
    • 2011
  • 수소를 제어하기 위한 기술 중 최근에 각광받는 방법으로는 피동형 촉매 재결합기(PAR)가 있다. PAR설비에서의 핵심기술인 촉매를 제조한 후 이를 이용하여 수소 재결합 성능 평가를 실시하였다. 실험은 공간속도(GHSV)를 $35000{\sim}100000hr^{-1}$로 변경하며 실시한 결과 공간속도가 증가할수록 수소의 전화율은 감소하였으나 시간당 제거되는 수소의 중량은 크게 증가하였다. 백금의 담지량을 달리하여 촉매를 제조한 후 실험을 수행한 결과 3 wt%에서는 별다른 전화율 차이를 보이지 않았으나 활성금속의 담지량이 증가하면서 승온속도가 증가되는 것을 확인 할 수 있었다. 이와 같은 공간속도 및 촉매 담지량 실험 결과 본 촉매는 상온 상압에서 80% 이상의 높은 전화율을 보이는 것을 확인 할 수 있었다.

군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가 (Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building)

  • 손병후;조경주;조동우
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.