• 제목/요약/키워드: Passive elements

검색결과 317건 처리시간 0.023초

The Optimal Design of Passive Shimming Elements for High Homogeneous Permanent Magnets Utilizing Sensitivity Analysis

  • Yao, Yingying;Choi, Yong-Kwon;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.461-465
    • /
    • 2006
  • This paper presents a useful and simple method to design the passive skimming system for homogeneous permanent magnets based on numerical optimization. To simulate the effects of manufacturing and assembling tolerances, the actual geometrical parameter of the magnet with a derivation is suggested. Then, the optimal design model oi a passive shim system is set up to correct the derivative of field homogeneity. The numbers, sizes and locations of the passive shims are optimized by the steepest descent algorithm combined with design sensitivity analysis. Two implementations show that the proposed method can achieve the required homogeneity of the field with the minimum quantity of ferromagnetics.

4절링크의 전달각에 기초한 충격흡수식 안전기구 (Shock-Absorbing Safety Mechanism Based on Transmission Angle of a 4-Bar Linkage)

  • 박정준;김병상;송재복
    • 대한기계학회논문집A
    • /
    • 제29권11호
    • /
    • pp.1534-1541
    • /
    • 2005
  • Unlike industrial manipulators, the manipulators mounted on service robots are interacting with humans in various aspects. Therefore, safety has been one of the most important design issues. Many compliant robot arms have been introduced for safety. It is known that passive compliance method has faster response and higher reliability than active ones. In this paper, a new safety mechanism based on passive compliance is proposed. Passive mechanical elements, specifically transmission angle of the 4-bar linkage, springs and shock absorbing modules are incorporated into this safety mechanism. This mechanism works only when the robot arm exerts contact force much more than the human pain tolerance. Validity of this mechanism is verified by simulations and experiments. It is shown that the manipulator using this mechanism provides higher performance and safety than those using other passive compliance mechanisms or active methods.

미소 채널의 형상변화에 의한 혼합효율에 관한 수치 해석적 연구 (Numerical Analysis on Mixing Efficiency in a Micro-channel with Varied Geometry)

  • 윤준용;한규석;변성준
    • 공업화학
    • /
    • 제16권2호
    • /
    • pp.275-281
    • /
    • 2005
  • 본 연구에서는 격자 볼츠만 방법 중 Scalar Passive 코드를 사용하여 미소채널 내에서의 수동형 믹서의 혼합에 대하여 계산을 수행하였다. 미소채널 내에서의 수동형 믹서의 혼합에 대하여 유선과 압력분포를 통해 혼합과 압력 강하를 물리적으로 규명하였으며, 혼합에 영향을 주는 인자에 대해서 알아보았다. 수동형 믹서의 경우 고정물의 간격보다는 고정물의 개수와 고정물의 크기가 혼합효율과 압력강하에 큰 영향을 주었다.

기생 요소 효과들을 고려한 얇은 두께의 LTCC 저역 통과 필터 설계 (A Thin LTCC Low Pass Filter Design Considering Parasitic Elements Effects)

  • 김유선;임영석
    • 대한전자공학회논문지TC
    • /
    • 제45권12호
    • /
    • pp.128-132
    • /
    • 2008
  • 본 논문에서는 LTCC(low temperature co-fired ceramic) 공정을 이용한 삽입된 수동 소자들을 갖는 필터 설계를 하였다. 우수한 성능과 소형화를 위해서 제안된 적층 구조의 기생 성분들은 제안된 회로 변환 과정을 통해 전체 필터 회로에서 긍정적인 효과를 갖도록 하였다. 그 결과 소형화된 저역 통과 필터는 다른 논문들의 소형화된 구조들에 비해 50프로 이상의 적은 두께를 갖을 뿐만 아니라 0.5 GHz와 5 GHz 사이에서 이상적인 저역 통과 필터의 응답을 보였다.

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • 제25권4호
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

솔라셀을 이용한 가시광 인식용 수동형 트랜스폰더 (A Passive Transponder for Visible Light Identification Using a Solar Cell)

  • 이성호
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.238-244
    • /
    • 2014
  • In this paper, we introduce a new passive transponder that operates without external power in a visible light identification system. The transponder consists of a solar cell, a photodiode, a microprocessor, and a visible LED. When a reader sends light to the transponder, the solar cell generates current from the reader light and supplies power to the other elements in the transponder. At the same time, the photodiode detects the pulse in the reader light and initiates a microprocessor to generate and send a responding light to the reader. In experiments, we realized a passive transponder using a solar cell that operated at a distance of 1m without external power.

Effect of Chemical Passivation Treatment and Flow on the Corrosion of 304 Stainless Steel in Hydrochloric Acid Solution

  • Zhao, Jie;Cheng, Cong Qian;Cao, Tie Shan
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.273-279
    • /
    • 2015
  • Effects of passive film quality by chemical passivation and solution flow on the corrosion behavior of 304 stainless steel in HCl solution were investigated using a coloration indicator, and by corrosion weight loss, electrochemical polarization and element dissolution measurements. A high redness degree suggests a low passive-film integrity for 304 stainless steel following air exposure, while the minimum redness degree for the samples after chemical passivation suggests a high passive-film integrity. In the static condition, samples subjected to air exposure exhibited a high corrosion rate and preferential dissolution of Fe. Chemical passivation inhibited the corrosion rate due to the intrinsically high structural integrity of the passive film and high concentrations of Cr-rich oxides and hydroxide. Solution flow accelerated corrosion by promoting both the anodic dissolution reaction and the cathodic reaction. Solution flow also altered the preferential dissolution to fast uniform dissolution of metal elements.

부하설비의 고조파 저감을 위한 수동필터 설계 (Design of Passive Filter for Harmonic Elimination of the Load System)

  • 손재현;강창섭;이홍기;윤철섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.276-278
    • /
    • 1997
  • The aim of this study is to design a passive filter for the elimination of harmonics. For this design, the harmonics wave generating from the six pulse rectifier was measured and its characteristics were analyzed. We also calculated the quantity of harmonic current by changing the system operational conditions. According to this field data and calculated results. we determined the elements of the passive filter. The simulation results indicate the efficiency of designed passive filter.

  • PDF

에너지 저감형 그린홈 프로토타이핑을 위한 설계요소 분석 연구 (Analytic Study on the Design Elements for Energy Conservative Green-Home Prototyping)

  • 김정은;장성주;하미경;성혜연;김경완
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.63-70
    • /
    • 2011
  • In respond to the global energy crisis and climate change, there have been many ongoing national efforts to develop a sustainable housing prototype followed by "2 million Green Home Project" in Korea. More than 50% of nation's population are currently living in apartment housing thus the country is seriously in need of developing green apartment prototype. In this research, we focused on energy-conservative green apartment design prototype that have both passive components and active systems explored in a systemic design approach. After selecting an existing basic apartment unit, we analyzed and compared statistical data with the simulated annual energy consumption to match these two data sets for validating simulation accuracy performed with TRNSYS package. We performed energy simulations with different passive design factors such as varied insulation thickness, window types and infiltration rates as well as the active design factors including boilers and lighting fixtures to analyze their impacts on the energy performance of the housing unit using TRNSYS software. As a result, we acquired significant energy reduction effect with explored design strategies but the life cycle cost analysis for the final design guidline would need to be performed. In this study, we focused on a systematic comparative energy analysis based on TRNSYS that can improve the design of a green apartment housing.

A Compact LTCC Dual-Band WLAN Filter using Two Notch Resonators

  • Park, Jun-Hwan;Cheon, Seong-Jong;Park, Jae-Yeong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.168-175
    • /
    • 2013
  • This paper presents compact dual-band WLAN filter and filter module. They were developed by embedding all of the passive lumped elements into a LTCC substrate. In order to reduce the size/volume of the filter and avoid EM parasitic couplings between the passive elements, the proposed filter was designed using a 3rd order Chebyshev circuit topology and J-inverter transformation technology. The 3rd order Chebyshev bandpass filter was firstly designed for the band-selection of the 802.11b and was then transformed using finite transmission zeros technologies. Finally, the dual-band filter was realized by adding two notch resonators to the 802.11b filter circuit for the band-selection of the 802.11a/g. The maximum insertion losses in the lower and higher passbands were better than 2.0 and 1.3 dB with minimum return losses of 15 and 14 dB, respectively. Furthermore, the filter was integrated with a diplexer to clearly split the signals between 2 and 5 GHz. The maximum insertion and minimum return losses of the fabricated module were 2.2 and 14 dB at 2.4 - 2.5 GHz, and 1.6 and 19 dB at 5.15 - 5.85 GHz, respectively. The overall volume of the fabricated filter was $2.7{\times}2.3{\times}0.59mm^3$.