• Title/Summary/Keyword: Passive Technique

Search Result 444, Processing Time 0.025 seconds

Experimental Retrieval of Soil Moisture for Cropland in South Korea Using Sentinel-1 SAR Data (Sentinel-1 SAR 데이터를 이용한 우리나라 농지의 토양수분 산출 실험)

  • Lee, Soo-Jin;Hong, Sungwook;Cho, Jaeil;Lee, Yang-Won
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.947-960
    • /
    • 2017
  • Soil moisture plays an important role to affect the Earth's radiative energy balance and water cycle. In general, satellite observations are useful for estimating the soil moisture content. Passive microwave satellites have an advantage of direct sensitivity on surface soil moisture. However, their coarse spatial resolutions (10-36 km) are not suitable for regional-scale hydrological applications. Meanwhile, in-situ ground observations of point-based soil moisture content have the disadvantage of spatially discontinuous information. This paper presents an experimental soil moisture retrieval using Sentinel-1 SAR (Synthetic Aperture Radar) with 10m spatial resolution for cropland in South Korea. We developed a soil moisture retrieval algorithm based on the technique of linear regression and SVR (support vector regression) using the ground observations at five in-situ sites and Sentinel-1 SAR data from April to October in 2015-2017 period. Our results showed the polarization dependency on the different soil sensitivities at backscattered signals, but no polarization dependence on the accuracies. No particular seasonal characteristics of the soil moisture retrieval imply that soil moisture is generally more affected by hydro-meteorology and land surface characteristics than by phenological factors. At the narrower range of incidence angles, the relationship between the backscattered signal and soil moisture content was more distinct because the decreasing surface interference increased the retrieval accuracies under the condition of evenly distributed soil moisture (during the raining period or on the paddy field). We had an overall error estimate of RMSE (root mean square error) of approximately 6.5%. Our soil moisture retrieval algorithm will be improved if the effects of surface roughness, geomorphology, and soil properties would be considered in the future works.

LOW PERMEABILITY THROUGH THE BLOOD-BRAIN BARRIER OF MORPHINE GLUCURONIDES.

  • Kang, Young-Sook;Ulrich Bickel;Oliver P. Schumacher;Karlheinz Voigt
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.246-246
    • /
    • 1996
  • The glucuronide conjugates of morphine have been claimed to exert significant neuropharmacological effects. Morphine-6-glucuronide (M6G) may be a potent opioid agonist in vivo, and morphine-3-glucuronide (M3G) may act as a weak opioid antagonist. The present study addressed the permeability of the blood-brain barrier (BBB) for these metabolites compared to morphine. Tracers were prepared by enzymatic glucuronidation of U-methyl-$^3$H]-morphine. Brain uptake in rats was measured by the internal carotid artery perfusion technique and after i.v. bolus injections. In the perfusion experiments morphine showed a permeability-surface area product (PS) of 3.52${\pm}$0.61 ${\mu}$L min$\^$-1/ g$\^$-1/ Uptake seems to be mediated by passive diffusion and was not saturable by 100 ${\mu}$M morphine in the perfusate. The BBB permeability of [$^3$H]-M3G and [$^3$H]-M6G was too low to be quantified after 5 min of perfusion. Brain uptake of [$^3$H]-M3G and [$^3$H]-M6G 60 min after i.v. bolus injection reached 0.0060${\pm}$0.0003 and 0.0030${\pm}$0.0005% injected dose per g, respectively. From these brain concentrations and from the corresponding plasma concentration - time curves, BBB PS values of 0.14${\pm}$ 0.02 ${\mu}$L min$\^$-1/g$\^$-1/ and 0.11 ${\pm}$ 0.01 ${\mu}$L min$\^$-1/g$\^$-1/, respectively, were calculated. The ratio of BBB PS values is complementary to the analgesic potencies of morphine and M6G after different routes of administration. The low PS of MSG explains, why it is approximate]y equipotent to morphine after systemic injection, although it is about 2 orders of magnitude more potent than morphine after administration directly into the central nervous system.

  • PDF

Comparison the Initial Effects of Nerve Mobilization Techniques, Static Stretching and Contract-Relax on Hamstring Flexibility and Walking Ability in Post-Stroke Hemiplegia Patients (뇌졸중으로 인한 편마비 환자의 슬괵근 유연성과 보행능력에 대한 신경가동기법, 정적 신장기법 및 수축-이완기법의 즉각적 효과 비교)

  • Kim, Yong-Jeong;Kim, Taek-Yean;Kim, Suhn-Yeop;Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.369-379
    • /
    • 2011
  • Purpose : The purpose of this study is to compare the initial effect of nerve mobilization (NM), static stretching (SS), and contract-relax (CR) techniques to find the best method in improving hamstring flexibility and gait function in patients with hemiplegia. Methods : Eleven patients with hemiplegia were included in this study. Passive knee extension (PKE) range of motion and the sit and reach (SR) test were used to measure hamstring flexibility, while timed up and go (TUG) and the 10m walking (10MW) test were used to measure the subject's gait. Measurements on each test were assessed prior to the experiment, immediately following the experiment, and 30 minutes after the experiment. Analysis of the results utilized a repeated measures analysis of variance to examine hamstring flexibility and the difference in walking ability. Results : The results suggest significant increases in NM, SS, and CR techniques as they relate to hamstring flexibility (p<.05) following (both immediate and 30 minutes post experiment) PKE range of motion and the SR test, but post-hoc showed no significant difference between the three techniques (p>.05). Additionally, the results suggest significant increases in NM, SS, and CR techniques as they relate to gait function (p<.05) following the TUG test, but found no significant difference in the 10MW test (p>.05). Post-hoc analysis between the three techniques suggests that only the NM technique significantly changed gait function. The time of TUG and 10MW test showed no significant difference between the three techniques before an experiment, just after an experiment, and 30 minutes following the experiment according to the measurement points in time (p>.05). Conclusion : This study suggests NM, SS, and CR techniques immediately improve hamstring length and flexibility while improving gait function in patients with hemiplegia.

Development of an Imaging-DOAS System for 2-D Remote Sensing of Atmospheric Gases (대기가스오염물질의 이차원 원격 모니터링을 위한 Imaging-DOAS 개발)

  • Lee, Han-Lim;Lee, Chul-Kyu;Jung, Jin-Sang;Park, Jeong-Eun;Kim, Young-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.150-157
    • /
    • 2006
  • Spatially resolved remote identification and quantification of trace gases in the atmosphere is desirable in various fields of scientific research as well as in public security and industrial contexts. Environmental observations investigating causes, extent md consequences of air pollution are of fundamental interest. We present an Imaging-DOAS system, a ground based remote sensing instrument that allows spatially resolved mapping of atmospheric trace gases by a differential optical absorption spectroscopy(DOAS) with sun scattered light as the light source. A passive DOAS technique permits the identification and quantification of various gases, e.g., $NO_2,\;SO_2,\;and\;CH_2O$, from their differential absorption structures with high sensitivity. The Imaging-DOAS system consists of a scanning mirror, a focusing lens, a spectrometer, a 2-D CCD, ad the integral control software. An imaging spectrometer simultaneously acquires spectral information on the incident light in one spatial dimension(column) and sequentially scans the next spatial dimension with a motorized scanning mirror. The structure of the signal acquisition system is described in detail and the evaluation method is also briefly discussed. Applications of imaging of the $NO_2$ contents in the exhaust plumes from a power plant are presented.

A Design and Implementation of RSS Data Collecting Engine based on Web 2.0 (웹 2.0 기반 RSS 데이터 수집 엔진의 설계 및 구현)

  • Kang, Pil-Gu;Kim, Jae-Hwan;Lee, Sang-Jun;Chae, Jin-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1496-1506
    • /
    • 2007
  • The environment of web service has changed a great deal due to the progress of internet technology and positive participation of users. The established web service is static and passive, but the recent web service is becoming dynamic and active. Web 2.0 reflects current web service change well. The primary feature of web 2.0 is positive participation of users. Since the size of generated information is becoming larger, it is highly required to share the information fast and correctly. The technology to satisfy this need is web syndication and tagging in web 2.0. The web syndication makes feeds for another site or users to receive the content of web site. In addition, the tagging is the kernel of a information. Many internet users share rapidly the information through tag search. In this paper, we propose the efficient technique to improve the web 2.0 technology such as web syndication and tagging by using the data collection engine. Data collection engine has stored in a database, a user's Web site to use the information. and it has a user's Web site with access to updated data to collect. The experimental results show that our approach can improve the search speed up to 3.14 times better than the existing method and reduce the size of data up to 66% for building associated tags.

  • PDF

Temperature Compensation of 8 Channel DWDM Multiplexer Using All Optical fiber Mach-Zehnder Structure (전광섬유형 8채널 DWDM용 광다중화기의 온도보상 특성)

  • Chang, Jin-Hyeon;Jung, Jin-Ho;Kim, Young-Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.8A
    • /
    • pp.697-704
    • /
    • 2005
  • In this paper, Passive Temperature Compensation Technology is apply to 8-channel Optical multiplexer with 1000Hz channel spacing. The 8-channel multiplexer is fabricated by connecting three cascaded Mach Zehnder Interferometer(MZI) of optical fiber type, and each interferometer has the wavelength interval of 100GHz, 2000Hz and 4000Hz, respectively. Furthermore, to acquire uniform insertion loss, it is fabricated by using Wavelength Flatten Coupler(WFC) in which the variation of insertion loss is low. $CO_2$ laser to adjust precisely the wavelength. The optical fiber is very sensitive in the thermal variation around. Thus, When fabrication the prototype, it is applied a technique to compensate the optical thermal effect because the center wavelength at the output is shifted according to the thermal variation around. In summary, The prototype composed by eight cascaded MZI has an insertion loss of 5.5 dB, the bandwidth of 0.8nm at 0.5 dB point, and channel crosstalk of 25 dB. Furthermore, the loss dependent on polarization is measured as 0.06dB. Consequently, the output wavelength is shifted within 0.05 m when the surrounding temperature varies until $60^{\circ}C$

Correction of Secondary cleft lip-nasal deformity; secondary rhinoplasty in children and adults (구순열 이차비기형의 교정; 아동과 성인에서의 이차 비성형술)

  • Song Gin-Ah;Myung Hoon;Hwang Soon-Jung;Seo Byoung-Moo;Lee Jong-Ho;Choung Pill-Hoon;Kim Myung-Jin;Choi Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.6 no.1
    • /
    • pp.17-25
    • /
    • 2003
  • Correction of the cleft-lip nasal deformity is a difficult task that requires clear understanding of the associated complex anatomy and function as well as the operation time, the selection of an operation method, On the expectation that it helps enhance understanding the current trend of cleft-rhinoplasty, authors analyzed secondary rhinoplasty between 1999 and 2002, In both the unilateral and bilateral cleft lip rhinoplasty, we reviewed the timing of repair, site of correction and it's major technique, incision or approach method, autogenous cartilage graft method, All patients with a septal deviation did not have a septal surgery, We were active in alar and nasal tip surgery and passive in septal and dorsal deformity correction, And for children, we used a conservative method but for adults, we used radical approach, Most surgeries are focused on esthetic goal and we thought that objective evaluation for nasal obstruction was needed for bener and predictable outcome.

  • PDF

STSAT-3 Main Payload, MIRIS Flight Model Developments

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Ree, Chang-Hee;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Nam, Uk-Won;Park, Jang-Hyun;Lee, Duk-Hang;Ka, Nung-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • The Main payload of the STSAT-3 (Korea Science & Technology Satellite-3), MIRIS (Multipurpose Infra-Red Imaging System) has been developed for last 3 years by KASI, and its Flight Model (FM) is now being developed as the final stage. All optical lenses and the opto-mechanical components of the FM have been completely fabricated with slight modifications that have been made to some components based on the Engineering Qualification Model (EQM) performances. The components of the telescope have been assembled and the test results show its optical performances are acceptable for required specifications in visual wavelength (@633 nm) at room temperature. The ensuing focal plane integration and focus test will be made soon using the vacuum chamber. The MIRIS mechanical structure of the EQM has been modified to develop FM according to the performance and environment test results. The filter-wheel module in the cryostat was newly designed with Finite Element Analysis (FEM) in order to compensate for the vibration stress in the launching conditions. Surface finishing of all components were also modified to implement the thermal model for the passive cooling technique. The FM electronics design has been completed for final fabrication process. Some minor modifications of the electronics boards were made based on EQM test performances. The ground calibration tests of MIRIS FM will be made with the science grade Teledyne PICNIC IR-array.

  • PDF

Reliability Improvement of the Electronic Security Fence Using Friction Electricity Sensor by Analyzing Frequency Characteristic of Environmental Noise Signal (환경잡음신호의 주파수특성 분석에 의한 전자보안펜스의 신뢰성 향상)

  • Yun, Seok Jin;Won, Seo Yeon;Kim, Hie Sik;Lee, Young Chul;Jang, Woo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.173-180
    • /
    • 2015
  • A passive type of fence security system was developed, which was based on electric charge detection technique. The implemented fence security system was installed at outskirts of greenhouse laboratory in the University of Seoul. The purpose of this research is to minimize false alarms by analyzing environmental noise. The existing system determines the intrusion alarm by analyzing the power of amplified signal, but the alarm was seriously affected by natural strong wind and heavy rainfall. The SAU(Signal Analysis Unit) sends input signals to remote server which displays intrusion alarm and stores all the information in database. The environmental noise such as temperature, humidity and wind speed was separately gathered to analyze a correlation with input signal. The input signal was analyzed for frequency characteristic using FFT(Fast Fourier Transform) and the algorithm that differentiate between intrusion alarm and environmental noise signal is improved. The proposed algorithm is applied for the site for one month as the same as the existing algorithm and the false alarm data was gathered and analyzed. The false alarm number was decreased by 98% after new algorithm was applied to the fence. The proposed algorithm improved the reliability at the field regarding environmental noise signal.

Normal Range of Shoulder Motion and Fluoroscopic Analysis of Motion Fraction (정상인의 견관절 운동범위 및 방사선 투시기를 이용한 운동분율측정)

  • Choi Chang-Hyuk;Yun Gi-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.221-229
    • /
    • 1998
  • We measured, with manual goniometer, the active and passive arc of motion of the shoulder in 31 healthy male subjects who were right-hand dominant and who ranged in age from twenty to thirty-one years. Among ten directions through the four motion plane, the range of motion on the dominant side were significantly smaller than those on the non-dominant side in the motion of six directions. We also measured the motion fraction of the glenohumeral and scapulothoracic movement using fluoroscope in 30-degree intervals of arm elevation in the scapular plane. The ratio of glenohumeral to scapulothoracic movement(θGH/θST) was 1.6 for the full range of motion in scapular plane. At the lower angles of abduction, scapulothoracic movement was slight compared with glenohumeral movement. The motion fraction of scapulothoracic joint was increased from 60-degree to 150 degree of arm angle especially between 120 to 150 degree. During arm elevation, scapula was also extended from 42 degrees to 20 degrees tilting as well as internal rotation. The measuring technique of glenohumeral to scapulothoracic movement(θGH/θST) with fluoroscopy could be applied to the simple radiographic measurement at the out-patient clinic in order to identify the pathology and recovery of shoulder motion after treatment.

  • PDF