• Title/Summary/Keyword: Passive PFC

Search Result 31, Processing Time 0.031 seconds

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

Improved Passive Power Factor Correction Circuits of Electronic Ballasts for fluorescent lamps (형광등용 전자식 안정기에 적합한 수동 역률개선회로의 제안 및 특성 개선에 관한 연구)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2795-2797
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

Design and Analysis of High-order Active Input Filter for Power Factor Correction(PFC) Converter (역률 개선 컨버터용 고차 능동 필터의 설계 및 분석)

  • Lee, Dong-Young;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.259-261
    • /
    • 1996
  • In this paper, active input filter for power factor correction(PFC) circuit employing ripple arrent and voltage cancellation is proposed to reduce filter's size and cost, and to make filter design easy. Switching ripple current and voltage can be sensed through the secondary windings of filter inductor. Single stage passive filter can achieve high order filter characteristics by using active ripple current and voltage cancellation technique. Conventional high order passive filter and its problems are suggested. Analysis of active filter and design procedure are detailed. Simulation result is presented to verify high order filter characteristics of proposed scheme.

  • PDF

The development of 110/220V alternative static output ballast by using passive power factor correction circuit (수동역률 개선회로를 이용한 110/220V 겸용 정출력 안정기 개발)

  • Song, Myung-Suk;Jo, Gye-Hyun;Park, Chong-Yeun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.210-213
    • /
    • 2004
  • In this paper, we propose the passive PFC(Power Factor Correction) circuit of an electronic ballast with the constant power the detection circuit for 110 or 220 volt. The proposed PFC circuit is composed with the modified dither circuit and the input voltage detection circuit. We have concluded that the proposed method is the attractive method to improve of power factor for the electronic ballast with the input voltage regulation and it is a similar experimental results with other active power factor correction method using other PWM ICs.

  • PDF

Basic Study of a Phase-Shifted Soft Switching High-Frequency Inverter with Boost PFC Converter for Induction Heating

  • Kawaguchi, Yuki;Hiraki, Eiji;Tanaka, Toshihiko;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.192-199
    • /
    • 2008
  • This paper is mainly concerned with a high frequency soft-switching PWM inverter suitable for consumer induction heating systems. The proposed system is composed of a soft switching chopper based boost PFC converter stage with passive snubber and phase shifted PWM controlled full bridge ZVZCS high frequency inverter stage. Its fundamental operating performances are illustrated and evaluated in the experimental results. Its effectiveness is substantially proved on the basis of the experimental results from a practical point of view.

A Study on Electronic Ballast for 1[kW] Metal-Halide Lamp Developed by Eliminating Acoustic Resonance using Frequency Modulation Method (주파수 변조 기법을 이용하여 음향공명 현상을 제거한 1[kW] 메탈 핼라이드 램프용 전자식 안정기 개발)

  • Park, Chong-Yun;Lee, Bong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.10-18
    • /
    • 2008
  • This paper presents the design and imelementation of an electronic ballast with a passive PFC structure from which acoustic resonance of the metal halide lamp was removed by introducing the frequency modulation(FM) method. The proposed ballast consists of an EMI filter, passive PFC circuit full-bridge inverter, LC resonance type igniter and a circuit for removing acoustic resonance. The FM method solved two problems associated with single frequency driving: variation of the acoustic resonance range according to lamp aging and the acoustic resonance range discrepancy caused by different materials sealed inside the arc tube and their pressures for arc tubes of identical sizes from different manufacturers. Performance of the prototype developed for this study of the electronic ballast for 1[kW] metal halide lamp was verified by evaluating its optical conversion efficiency, input PF, input current THD and power conversion efficiency.

Low Cost and High Performance Single Phase UPS Using a Single-Loop Robust Voltage Controller

  • Ji, Jun-Keun;Ku, Dae-Kwan;Lim, Seung-Beom
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.695-701
    • /
    • 2015
  • Uninterruptible Power Supplies (UPSs) can be largely divided into the passive-standby, line-interactive and double-conversion methods. This paper proposes a double-conversion UPS with a low cost and high performance. This single phase UPS uses a single-loop robust voltage controller and 1-switch voltage doubler strategy PFC. The proposed UPS is composed of a single phase PFC, a half-bridge inverter, a battery charger and a battery discharger. Finally, the validity of proposed UPS was verified by various experimental tests.

Power factor improvement of LED driver using Valley-fill circuit and a Boosting Inductor (밸리 필 회로 및 부스팅 인덕터를 이용한 LED 구동회로의 역률 개선)

  • Park, Chong-Yeun;Lee, Hak-Beom;Yoo, Jin-Wan
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.103-107
    • /
    • 2011
  • In this paper, a method is proposed to improve power factor and the input current THD in LED driver circuit. The researched circuit consists of a valley-fill circuit and boosting inductor and a Buck converter. Valley-fill circuit is a passive PFC and simplified structure, the buck converter is operated with current feedback. The switching frequency is 50KHz in LED driver circuit and LED forward current is constant. A valley-fill type PFC circuit for LED driver(15Watt) has been implemented, and the validity of proposed method is shown by is simulation and experimental result.

  • PDF

Passive Power Factor Correction Circuits for Electronic Ballasts using Voltage-Fed and Current-Fed Resonant Inverters (전압원 및 전류원 구동 공진형 인버터로 구성된 형광등용 전자식 안정기의 역률개선에 적합한 수동 역률 개선 회로에 관한 연구)

  • Chae, Gyun;Ryu, Tae-Ha;Cho, Gyu-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.266-269
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF