• Title/Summary/Keyword: Passive Component

Search Result 200, Processing Time 0.029 seconds

Continuing Professional Development of Pharmacists and The Roles of Pharmacy Schools (약사의 전문직업성개발과 약학대학의 역할)

  • Hyemin Park;Jeong-Hyun Yoon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.4
    • /
    • pp.281-287
    • /
    • 2022
  • Pharmacists should maintain professional competencies to provide optimal pharmaceutical care services to patients, which can be achieved through continued commitment to lifelong learning. Traditionally continuing education (CE) has been widely used as a way of lifelong learning for many healthcare professionals. It, however, has several limitations. CE is delivered in the form of instructor-led education focused on multiple learners. Learning is passive and reactive for participants, so it sometimes does not lead to bringing behavioral changes in workplace performance. Therefore, recently the concept of lifelong learning tends to move from CE toward continuing professional development (CPD). CPD is an ongoing process that improves knowledge, skills, and competencies throughout a professional's career. It is a more comprehensive structured approach toward the enhancement of personal competencies. It emphasizes an individual's learning needs and goals and enables learning to become proactive, conscious, and self-directed. CPD consists of four stages: reflect, plan, learn, and evaluate. CE is one component of CPD. Each stage is recorded in a CPD portfolio. There are many practical difficulties in implementing the complete CPD system for lifelong learning of pharmacists in many countries including Korea. Applying a hybrid form that utilizes CPD and CE together, as in the case of some countries, could be an alternative. Furthermore, in undergraduate pharmacy education, it is necessary to teach students about CPD and train them on how to perform CPD as a pharmacist.

Performance-based seismic evaluation and practical retrofit techniques for buildings in China

  • Wang, Hao;Sun, Baitao;Chen, Hongfu
    • Earthquakes and Structures
    • /
    • v.22 no.5
    • /
    • pp.487-502
    • /
    • 2022
  • China is prone to earthquake disasters, and the higher seismic performance is required by many existing civil buildings. And seismic evaluation and retrofit are effective measures to mitigate seismic hazards. With the development of performance-based seismic design and diverse retrofit technology for buildings, advanced evaluation methods and retrofit strategies are in need. In this paper, we introduced the evolution of seismic performance objectives in China combined with performance-based seismic design. Accordingly, multi-phase evaluation methods and comprehensive seismic capacity assessment are introduced. For buildings with seismic deficiency or higher performance requirements, the retrofit technologies are categorized into three types: component strengthening, system optimization, and passive control. Both engineering property and social property for the retrofit methods are discussed. The traditional seismic retrofit methods usually are costly and disturbing, and for example in Beijing, seismic strengthening costs approx. 1000 RMB/m2 (for 160 USD/m2), for hospital building even more expensive as 5000 RMB/m2(for 790 USD/m2). So cost-efficient and little disturbance methods are promising techniques. In the end, some opinions about the retrofit strategy and schemes category are shared and wish to discuss the situation and future of seismic retrofit in China.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Estimation of Long-term Water Demand by Principal Component and Cluster Analysis and Practical Application (주성분분석과 군집분석을 이용한 장기 물수요예측과 활용)

  • Koo, Ja-Yong;Yu, Myung-Jin;Kim, Shin-Geol;Shim, Mi-Hee;Akira, Koizumi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.870-876
    • /
    • 2005
  • The multiple regression models which have two factors(population and commercial area) have been used to forecast the water demand in the future. But, the coefficient of population had a negative value because proper regional classification wasn't performed, and it is not reasonable because the population must be a positive factor. So, the regional classification was performed by principal component and cluster analysis to solve the problem. 6 regional characters were transformed into 4 principal components, and the areas were divided into two groups according to cluster analysis which had 4 principal components. The new regression models were made by each group, and the problem was solved. And, the future water demands were estimated by three scenarios(Active, moderate, and passive one). The increase of water demand ore $89.034\;m^3/day$ in active plat $49,077\;m^3/day$ in moderate plan, and $19,996\;m^3/day$ in passive plan. The water supply ability as scenarios is enough in water treatment plant, however, 2 reservoirs among 4 reservoirs don't have enough retention time in all scenarios.

ICT inspection System for Flexible PCB using Pin-driver and Ground Guarding Method (핀 드라이버와 접지가딩 기법을 적용한 모바일 디스플레이용 연성회로기판의 ICT검사 시스템)

  • Han, Joo-Dong;Choi, Kyung-Jin;Lee, Young-Hyun;Kim, Dong-Han
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, ICT (in circuit tester) inspection system and inspection algorithm is proposed and detects whether inferiority exists or not in the mounted device on the flexible PCB in cell phones or mobile display devices. The system is composed of PD (pin-driver) and GGM (ground guarding method). The structural characteristics of these flexible PCB are analyzed, which is needed to input or output the test signal. Test signal to investigate the characteristics of passive components is generated using modified circuit diagram and proposed inspection algorithm. PM (pin-map) is decided on the basis of circuit diagram and has the information about the kind of test signal to be applied and the pad number for the test signal to be connected. PD is designed to load a proper test signal for a specific pad and is adjusted according to PM so that the reconstructed circuit has minimum node and mash. The proposed ICT inspection system is realized using PD and GGM. Using the system, an experiment for each passive component is done to investigate the measurement accuracy of the developed system and an experiment for real flexible PCB model is done to verity the effectiveness of the system.

Equivalent Transmission-Line Sections for Very High Impedances and Their Application to Branch-Line Hybrids with Very Weak Coupling Power

  • Ahn, Hee-Ran;Kim, Bum-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.2
    • /
    • pp.85-97
    • /
    • 2009
  • As operating frequency is raised and as more integration with active and passive elements is required, it becomes difficult to fabricate more than 120 ${\Omega}$ characteristic impedance of a mierostrip line. To solve this problem, an equivalent high impedance transmission-line section is suggested, which consists mainly of a pair of coupled-line sections with two shorts. However, it becomes a transmission-line section only when its electrical length is fixed and its coupling power is more than half. To have transmission-line characteristics(perfect matching), independently of coupling power and electrical length, two identical open stubs are added and conventional design equations of evenand odd-mode impedances are modified, based on the fact that the modified design equations have the linear combinations of conventional ones. The high impedance transmission-line section is a passive component and therefore should be perfectly matched, at least at a design center frequency. For this, two different solutions are derived for the added open stub and two types of high impedance transmission-line sections with 160 ${\Omega}$ characteristic impedance are simulated as the electrical lengths of the coupled-line sections are varied. The simulation results show that the determination of the available bandwidth location depends on which solution is chosen. As an application, branch-line hybrids with very weak coupling power are investigated, depending on where an isolated port is located, and two types of branch-line hybrids are derived for each case. To verify the derived branch-line hybrids, a microstrip branch-line hybrid with -15 dB coupling power, composed of two 90$^{\circ}$ and two 270$^{\circ}$ transmission-line sections, is fabricated on a substrate of ${\varepsilon}_r$= 3.4 and h=0.76 mm and measured. In this case, 276.7 ${\Omega}$ characteristic impedance is fabricated using the suggested high impedance transmission-line sections. The measured coupling power is -14.5 dB, isolation and matching is almost perfect at a design center frequency of 2 GHz, showing good agreement with the prediction.

Design and Implementation of Distributed Active Object System(DAOS) for Manufacturing Control Applications (공정 제어 응용을 위한 분산 능동 객체 시스템(DAOS)의 설계 및 구현)

  • Eum, Doo-Hun;Yoo, Eun-Ja
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.2
    • /
    • pp.141-150
    • /
    • 2001
  • Manufacturing conb'ol applications consist of concurrent active components such as robots, AGV's (Automatic Guided Vehicles), and conveyors. Running of manufacturing control programs is interactions among those components. We can enhance the productivity and extendability of manufacturing control applications by using the object-oriented teclmology that models those components as reusable objects. But the objects in current object-oriented technology that encapsulate state and behavior infonnation are passive in a sense that those respond only when messages are sent to them. In this paper, we introduce the Distributed Active Object Systems (DAGS) approach that SUPPOltS active objects. Since active objects encapsulate control infonnation in addition to state and behavior information under COREA/Java-based distributed environment, they can represent manufacturing control components better than the objects in ordimuy object-oriented technology. TIus control infonnation provides an object with a featme that can monitor its own status as well as other object's status connected by intelface valiables. Active objects can initiate a behavior according to the change of those status. Therefore, we can sb-uctmally assemble self-initiating active objects by using intelface variables to construct a system without describing bow to control distributed objects by using message passing. As the DAOS approach supports object composability, we can enhal1ce the productivity and extendability of disbibuted manufactming control applications even better than the ordil1alY object-oriented approach. Also, the DAOS approach supports better component reusability with active objects that encapsulate control information .

  • PDF

Study of Diplexer Fabrication with Embedded Passive Component Chips (수동소자 칩 함몰공정을 이용한 Diplexer 구현에 관한 연구)

  • Youn, Je-Hyun;Park, Se-Hoon;Yoo, Chan-Sei;Lee, Woo-Sung;Kim, Jun-Chul;Kang, Nam-Kee;Yook, Jong-Gwan;Park, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.30-30
    • /
    • 2007
  • 현재 다양한 종류의 RF 통신 제품이 시장에 등장하면서 제품의 경쟁력 확보에 있어 소형화 정도가 중요한 이슈가 되고 있다. Passive Device는 RF Circuit을 제작할 때 많은 면적을 차지하고 있으며 이를 감소시키기 위해 여러 연구가 진행되고 있다. 가장 효과적인 방법으로 반도체 집적기술로 크기를 줄이는 방법이 있으나, 공정이 비싸고 제작 시간이 오래 걸려 제품개발 시간과 개발비용이 상승하게 된다. 반면에 SoP-L 공정은 PCB 제작에 이용되는 일반적인 재료와 공정을 사용하므로 개발 비용과 시간을 줄일 수 있다. SoP-L의 또 하나 장점은 다종 재료를 다층으로 구성할 수 있다는 점이다. 최근 chip-type의 Device를 PCB 기판 안에 내장하는 방법의 RF Circuit 소형화 연구가 많이 진행되고 있다. 본 연구에서는 SoP-L 공정으로 chip-type 수동소자를 PCB 기판 내에 함몰하여 수동소자회로를 구현, 분석하여 보았다. 수동소자회로는 880 MHz~960 MHz(GSM) 영역과 1.71 GHz~1.88 GHz(DCS) 영역을 나누는 Diplexer를 구성하였다. 1005 size의 chip 6개로 구현한 Diplexer를 표면실장과 함몰공정으로 제작하고 Network Analyzer로 측정하여 비교하였다. chip 표면실장으로 구현된 Diplexer는 GSM에서 최대 0.86 dB의 loss, DCS에서 최대 0.68 dB의 loss가 나타났다. 표면실장과 비교하였을 때 함몰공정의 Diplexer는 GSM 대역에서 약 0.5 dB의 추가 loss가 나타났으며 목표대역에서 0.6 GHz정도 내려갔다. 이 결과를 바탕으로 두 공정 간 차이점을 확인하고, 함몰공정으로 chip-type 수동소자를 사용하였을 때 고려해야 할 점을 분석하였다. 이를 바탕으로 SoP-L 함몰공정의 안정성을 높여서 이것을 이용한 회로의 소형화에 적용이 가능할 것으로 기대한다. 특히 능동소자의 DC Power Control에서 고용량의 수동소자를 이용할 때 집적도를 높일 수 있을 것이다.

  • PDF

Performance of Passive UHF RFID System in Impulsive Noise Channel Based on Statistical Modeling (통계적 모델링 기반의 임펄스 잡음 채널에서 수동형 UHF RFID 시스템의 성능)

  • Jae-sung Roh
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.835-840
    • /
    • 2023
  • RFID(Radio Frequency Identification) systems are attracting attention as a key component of Internet of Things technology due to the cost and energy efficiency of application services. In order to use RFID technology in the IoT application service field, it is necessary to be able to store and manage various information for a long period of time as well as simple recognition between the reader and tag of the RFID system. And in order to read and write information to tags, a performance improvement technology that is strong and reliable in poor wireless channels is needed. In particular, in the UHF(Ultra High Frequency) RFID system, since multiple tags communicate passively in a crowded environment, it is essential to improve the recognition rate and transmission speed of individual tags. In this paper, Middleton's Class A impulsive noise model was selected to analyze the performance of the RFID system in an impulsive noise environment, and FM0 encoding and Miller encoding were applied to the tag to analyze the error rate performance of the RFID system. As a result of analyzing the performance of the RFID system in Middleton's Class A impulsive noise channel, it was found that the larger the Gaussian noise to impulsive noise power ratio and the impulsive noise index, the more similar the characteristics to the Gaussian noise channel.

Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program (WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가)

  • Kang, Yujin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2016
  • Thermal performance of wooden houses used by building materials effectively contributing to building energy saving has been improved. However, the performance was decreased to the condensation and mould growth from exterior wall because the moisture control was difficult to high insulation and airtightness. Therefore, the hygrothermal performance of exterior wall, that selected 5 types of wooden houses, evaluated using the hygrothermal simulation program: heat and moisture behavior, condensation and mould growth risk. Wooden houses were selected Rural houses standard plans '10 and '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$ type, EIFS and wood-based passive house. And the wall A, B, C, D and E were determined by layer component of each wall. The U-value of exterior wall are 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$. The OSB absolute water content of the wall A and C was exceeds the reference value of 20%, and it was confirmed that condensation occur at insulation material inner surface through the condensation evaluation in the winter. The wall D and E showed excellent results with condensation and water content evaluation compared to others. However, mould growth risk assessment in all five types of wall had have risk. We were determined that hygrothermal performance difference of exterior wall occur the difference in the layer structure rather than in thermal performance.