• Title/Summary/Keyword: Passive Component

Search Result 200, Processing Time 0.029 seconds

A study on integrated device TaN/$Al_2O_3$ thin film resistor development (TaN/$Al_2O_3$ 집적화 박막 저항소자 개발에 관한 연구)

  • Kim, I.S.;Cho, Y.R.;Min, B.K.;Song, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1476-1478
    • /
    • 2002
  • In recent years, the tantalum nitride(TaN) thin-film has been developed for the electronic resistor, inductor and capacitor. In this papers, this study presents the surface profile and sheet-resistance property relationship of reactive-sputtered TaN thin film resistor processed by TaN(tantalum nitride) on alumina substrate. The TCR properties of the TaN films were discussed in terms of crystallization and thin films surface morphology due to annealing temperature. It is clear that the TaN thin-films resistor electrical properties are low TCR related with it's annealing temperature and ambient annealing condition. Respectively, at $300{\sim}400^{\circ}C$ on vacuum and nitrogen annealed thin film resistor having a goof thermal stability and lower TCR properties then as deposited thin films expected for the application to the dielectric material of passive component.

  • PDF

New Active Muffler System Utilizing Destructive Interference by Difference of Transmission Paths (전달경로의 차이를 이용한 새로운 차량용 능동 머플러의 개발)

  • Hwang, Yo-Ha;Lee, Jong-Min;Kim, Seung-Jong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.5
    • /
    • pp.374-379
    • /
    • 2002
  • A new active muffler system has been developed and its superior performance on both noise reduction and engine torque increase is demonstrated with experiment. Main characteristic of the proposed muffler system is the use of destructive interference by transmission path difference of divided exhaust pipes to reduce major exhaust noise components thereby overcoming problems of other active exhaust noise control methods. The exhaust pipe is divided into two sections and joined again downstream. One divided pipe has a sliding mechanism to vary its length, which is controlled to make half wavelength transmission path difference for the major engine rpm frequency. In this system one divided pipe is used to control major rpm frequency and its Harmonics and another pipe is used to control noise component double the frequency of rpm. An after-market tuning muffler, which has very simple internal structure and minimal back pressure, is also installed to remove remaining wideband noise. To make the system to be small enough to be practical, conventional muffler is also installed and used in low rpm range and active muffler is only employed in high rpm range. Noise reduction of the proposed system is comparable to conventional passive muffler. The engine dynamo test has proved the proposed system can recover almost all the torque lost by conventional muffler.

A Study on the Active Traceback Scheme Respond ing to a Security Incident (침해사고 대응을 위한 능동적 역추적 기법에 관한 연구)

  • Park Myung Chan;Park Young Shin;Choi Yong Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.27-34
    • /
    • 2005
  • Current security reinforcement systems are Passive defense system that only blocks filter to all traffic from the attacker. So, Those are weak re-attack and Stepping Stones attack because active response about attacker is lacking. Also, present techniques of traceback need much time and manpower by log information collection and trace through the personal inspection and active response is lacking. In this paper, We propose technique for TCP connection traceback that can apply in present internet and trace to inserted marking on IP header to correspond re-attack and Stepping Stones attack. Therefore, Proposed technique is unnecessary correction of existing network component and can reduce size of marked information and overhead of resources.

  • PDF

Captive Flight Test System Configuration and Verification for Multi-mode Guidance Missile System (복합유도방식이 적용된 유도탄의 탑재비행시험(CFT) 시스템 구성 및 검증)

  • Park, Inchul;Heo, Wonyoung;Lee, Yongho;Jeong, Seyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.606-612
    • /
    • 2016
  • A Captive Flight Test(CFT) is used to verify the performance of missile component such as seeker and guiding algorithm of missile. Recently most of surface to air missile adapts multi-mode guidance method which include command guidance and active/passive guidance. A CFT system for missile system adapting multi-mode guidance method consists of pod equipment, command transmitting system and measuring system. In this paper, we proposed CFT system and testing method for missile which adapt multi-mode guidance, and system integration procedure by using distributed missile system integration method and procedure. The proposed CFT system and system integration method was applied to CFT of surface to air missile, and brought successful result.

Numerical verification of a dual system's seismic response

  • Phocas, Marios C.;Sophocleous, Tonia
    • Earthquakes and Structures
    • /
    • v.3 no.5
    • /
    • pp.749-766
    • /
    • 2012
  • Structural control through integration of passive damping devices within the building structure has been increasingly implemented internationally in the last years and has proven to be a most promising strategy for earthquake safety. In the present paper an alternative configuration of an innovative energy dissipation mechanism that consists of slender tension only bracing members with closed loop and a hysteretic damper is investigated in its dynamic behavior. The implementation of the adaptable dual control system, ADCS, in frame structures enables a dual function of the component members, leading to two practically uncoupled systems, i.e., the primary frame, responsible for the normal vertical and horizontal forces and the closed bracing-damper mechanism, for the earthquake forces and the necessary energy dissipation. Three representative international earthquake motions of differing frequency contents, duration and peak ground acceleration have been considered for the numerical verification of the effectiveness and properties of the SDOF systems with the proposed ADCS-configuration. The control mechanism may result in significant energy dissipation, when the geometrical and mechanical properties, i.e., stiffness and yield force of the integrated damper, are predefined. An optimum damper ratio, DR, defined as the ratio of the stiffness to the yield force of the hysteretic damper, is proposed to be used along with the stiffness factor of the damper's- to the primary frame's stiffness, in order for the control mechanism to achieve high energy dissipation and at the same time to prevent any increase of the system's maximum base shear and relative displacements. The results are summarized in a preliminary design methodology for ADCS.

Composite $BaTiO_3$ Embedded capacitors in Multilayer Printed Circuit Board (다층 PCB에서의 $BaTiO_3$ 세라믹 Embedded capacitors)

  • You, Hee-Wook;Park, Yong-Jun;Koh, Jung-Hyuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.110-113
    • /
    • 2008
  • Embedded capacitor technology is one of the effective packing technologies for further miniaturization and higher performance of electric packaging system. In this paper, the embedded capacitors were simulated and fabricated in 8-layered printed circuit board employing standard PCB processes. The composites of barium titanante($BaTiO_3$) powder and epoxy resin were employed for the dielectric materials in embedded capacitors. Theoretical considerations regarding the embedded capacitors have been paid to understand the frequency dependent impedance behavior. Frequency dependent impedance of simulated and fabricated embedded capacitors was investigated. Fabricated embedded capacitors have lower self resonance frequency values than that of the simulated embedded capacitors due to the increased parasitic inductance values. Frequency dependent capacitances of fabricated embedded capacitors were well matched with those of simulated embedded capacitors from the 100MHz to 10GHz range. Quality factor of 20 was observed and simulated at 2GHz range in the 10 pF embedded capacitors. Temperature dependent capacitance of fabricated embedded capacitors was presented.

Compact Wireless IPT System Using a Modified Voltage-fed Multi-resonant Class EF2 Inverter

  • Uddin, Mohammad Kamar;Mekhilef, Saad;Ramasamy, Gobbi
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.277-288
    • /
    • 2018
  • Wireless inductive power transfer (IPT) technology is used in many applications today. A compact and high-frequency primary side inverter is one of the most important parts of a WPT system. In this study, a modified class EF-type voltage-fed multi-resonant inverter has been proposed for WPT application at a frequency range of 85-100 kHz. Instead of an infinite input choke inductor, a resonant inductor is used to reduce loss and power density. The peak voltage stress across the MOSFET has been reduced to almost 60% from a class-E inverter using a passive clamping circuit. A simple yet effective design procedure has been presented to calculate the various component values of the proposed inverter. The overall system is simulated using MATLAB/SimPowerSystem to verify the theoretical concepts. A 500-W prototype was built and tested to validate the simulated results. The inverter exhibited 90% efficiency at nearly perfect alignment condition, and efficiency reduced gradually with the misalignment of WPT coils. The proposed inverter maintains zero-voltage switching (ZVS) during considerable load changes and possesses all the inherent advantages of class E-type inverters.

Shear Strength Comparison of Passive Component Using the Environmental-Friendly Lead-Free Solder (친환경 무연솔더를 적용한 수동부품의 솔더 접합부 전단강도 비교)

  • Song, Byeong-Suk;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.04a
    • /
    • pp.375-380
    • /
    • 2006
  • Recently European Council(EU) published the RoHS(restriction of the use of certain hazardous substances in electrical and electronic equipment) which is prohibit the use of Pb, Hg, Cd, $Cr^{+6}$, PBB or PBDE in the electrical and electronic equipments. So EU member States shall ensure that, from 1 July 2006, new electrical and electronic equipment put on the market does not contain 6 hazardous substances. So many kinds of projects is proceeding to ensure the reliability of Pb-free electronics in the worlds. Especially it is necessary to evaluate of Pb-free solder joints in electronics. Therefore, on this paper, we compared with solder joint strength of chip components, respectively SnPb, Pb-free solder as follows reliability test methods. We also measured the shear strength of solder joint and also compared the effects of environmental test methods. In this results, we analyzed and compared the shear strength variation as follows solder materials and reliability test conditions.

  • PDF

Topology optimization on vortex-type passive fluidic diode for advanced nuclear reactors

  • Lim, Do Kyun;Song, Min Seop;Chae, Hoon;Kim, Eung Soo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1279-1288
    • /
    • 2019
  • The vortex-type fluidic diode (FD) is a key safety component for inherent safety in various advanced reactors such as the sodium fast reactor (SFR) and the molten salt reactor (MSR). In this study, topology optimization is conducted to optimize the design of the vortex-type fluidic diode. The optimization domain is simplified to 2-dimensional geometry for a tangential port and chamber. As a result, a design with a circular chamber and a restrictor at the tangential port is obtained. To verify the new design, experimental study and computational fluid dynamics (CFD) analysis were conducted for inlet Reynolds numbers between 2000 and 6000. However, the results show that the performance of the new design is no better than the original reference design. To analyze the cause of this result, detailed analysis is performed on the velocity and pressure field using flow visualization experiments and 3-D CFD analysis. The results show that the discrepancy between the optimization results in 2-D and the experimental results in 3-D originated from exclusion of an important pressure loss contributor in the optimization process. This study also concludes that the junction design of the axial port and chamber offers potential for improvement of fluidic diode performance.

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.